.t Murrey Selman

.I w Vce Present Consolidated Edison Company of New York, Inc.

Indian Point Station (T

_j Broadway & Bleakley Ae.

April 30, 1986

[

i Buchanan, NY 10511 g

1 I Telephone (914) 737-8116 Ret Indian Point Unit Nos. 1,2 and 3 Docket No.s 50-03 and 50-247 and 50-286 Dr. Thomas E. Murley Regional Administrator Region I U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406

Dear Dr. Murley:

Transmitted herewith is one copy of the Indian Point Site Annual Environ-mental Protection Plan Report and the Indian Point Site Annual Radiological Environmental Operating Report for the period January 1, 1985 to December 31, 1985. These reports are submitted in accordance with Appendices A and B to facility licenses DPR-5, DPR-26 and DPR-64 for Indian Point Unit Nos.

1, 2 and 3, respectively. Specifically, these reports satisfy the require-ments of Section 5.4.1 of Part I of the ETSR; Section 6.9.1.5 of Appendix A, DPR-26; and Section 5.3.3.2 of Appendix B, DPR-64.

Should you or your staff have any questions, please contact us.

Very truly yours, 17.190.4.29.1 cc: Document Control Desk (18 copies)

U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Mr. Leroy W. Sinclair, President New York Power Authority 10 Columbus Circle New York, NY 10019 Senior Resident Inspector Indian Point Units 1 and 2 P.O. Box 38 Buchanan, NY 10511 Senior Resident Inspector Indian Point Unit 3

/

U.S. Nuclear Regulatory Commission h

[f P.O. Box 66 Buchanan, NY 10511

}

l 8605080246 860430 t

PDR ADOCK 05000003 R

pm L