ML20203P788

From kanterella
Jump to navigation Jump to search
Responds to Violations Noted in Safety Insp Rept Dtd 860403. Corrective Actions:Tech Spec Section 7.1 & Table 3 Updated to Conform to Current Lines of Mgt Incorporated by 1984 Reorganization
ML20203P788
Person / Time
Site: 05000087
Issue date: 04/25/1986
From: Scholand G
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Norelius C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
0438A, 0467A, 438A, 467A, NUDOCS 8605080164
Download: ML20203P788 (3)


Text

r

]::

OIUS Westinghouse wriear Traoing center Electric Corporation 505 snaon moiem Zaill!inois 60099 1312i872 4585 A'pril 25, 1986 Mr. C. E. Norelius Division of Reactor Projects U. S. Nuclear Regulatory Comission Region III 799 Roosevelt Road Glen Ellyn, IL 60137

Dear Sir:

This letter is in response to the routine safety inspection report to the Westinghouse Nuclear Training Reactor (Docket No. 50-87) dated April 3,1986.

Sincerely,

/ HM4' uCL Gerald W. Scholand, Manager Training & Operational Services GWS/ea Enclosure-cc:

K. M. Rueter A. T. Sabo A. J. Nardi W. A. Danker R. J. Sero NTR File 8605080164 86 7

PDR ADOCK O G

MAY1 y

0438a TOS/W-86-143 gg

\\

{

n RESPONSE TO NOTICE OF VIOLATION, APRIL 3,1986 WESTINGHOUSE NUCLEAR TRAINING REACTOR DOCKET NO. 50-87 i

TECHNICAL SPECIFICATION SECTION 7.1

^

1.

Corrective action taken is the submission of a change to Technical Specifications updating section 7.1 and Table 3 to conform to the current line of management incorporated by the reorganization in 1984.

2.

The line organization described in section 7.1 of Technical Specifications will be reviewed for any impact of future reorganizations within Westinghouse and updated as necessary.

3.

Full compliance will be achieved upon the approval of the Technical Specification change submitted.

\\

t

\\

0467a

+

r, RESPONSE TO NOTICE OF DEVIATION, APRIL 3,1986 WESTINGHOUSE NUCLEAR TRAINING REACTOR DOCKET NO. 50-87 1.

Corrective action taken is the submission of the delinquent RSC inspection report for the third quarter of 1985 to the RSC Chairperson with a copy to the WNTR Manager.

2.

The next semi-annual RSC meeting will be held May 1,1986. At this time, the committee will discuss the NRC inspection report. The requirements specified in the RSC charter for RSC inspections and subsequent submission of reports wi'il be reviewed with the RSC members. A plan to ensure timely submission of the RSC inspection reports will also be discussed at the meeting and fully implemented within 30 days of RSC approval of the plan.

3.

The third quarter of 1985 RSC inspection report was submitted to the RSC Chairperson with a copy to the WNTR Manager on April 25, 1986.

)

0467a

~

_