ML20203P317
| ML20203P317 | |
| Person / Time | |
|---|---|
| Site: | 07100594 |
| Issue date: | 04/04/1986 |
| From: | Browning B MARTIN MARIETTA ORDNANCE SYSTEMS, INC. (SUBS. OF |
| To: | NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| References | |
| 26780, NUDOCS 8605060584 | |
| Download: ML20203P317 (12) | |
Text
i L-~
7/-059' RETURN TO 396-SS pg.
MARTIN MARIETTA ORDNANCE SYSTEMS,INC.
MILAN AM AMMUNWON PLANT MILAN. TENNESSEE 38358 TELEPHONE (901) 6864101 April 4,
1986 CO 6
RECELVED i (E
nPR 101986 >
-9 g
Director d.S.NUClLUt RE.GUtyCRf CCWA 4
Office of Nuclear Material Safety and Safeguards O
Nt3 Jo U.S. Nuclear Regulatory. Co.mm.ission I' 83 8**'
Washington, D.
C.
20555 a
1 N
Dear Sir:
....... _. ~.....,,..
The attached Quality Assurance Prograta for inspec* ting, packaging, labelling and shipment of radioactive sealed source (AM-241) is submitted for Commission approval in accordaned with U.S. NRC' Rules and Regulations, Part 71 Subpart H. Paragraph 71.1,01(c).
Photographs of the radioactive source, reference sources and storage container (shipping container) are included to aid the evaluation.
Also attached is our check", Number 09740, in fhe amount of $150.00 which is a fee payment for evaluat, ion of.the Part 71 Quality' Assurance Program Application.
Request that Program approval be received as soon as possible.
~
Should additional informatiod be required, the point of contact is Mr.
Billy Blaylock, Area Code (901) 686-6739.
'~
~9e'ry ' t'r'My your s,
,..... ~.
MARTIN MARIETTA ORDNANCE SYSTEMS, INC.
........, U b).' d. 42Lm am.> Y4/d(
B.
R.
Browning, Vice President er Us Att.
cc: MAAP COR P
[ LO S
[y Leg.
1 b 'l ---- -------
1 2
waso Re tnitt r _. -
Check Tb. A N N - - -------- U Y g g Q T386 * ~g~
N Am:unt 4/54
~
Fa Catcet! /Of
- g ][m
.. - 7.c;- - -
g Typ20iR>
f d#'[~* - ------
pa Ct.Efd S
D to Check !- f Dat t 'm;1ct;d.
L _M- - - - -
D G
Dy h geg demy.c_:M -----
[
8605060584 8604 y
v PDR ADOCK 071 C
.,..y.--
v -
!- [
EW/g DOCKET NO.
36786 ~
co m aL uo.
[k/8Y/,fd DATE OF DOC.
[Y[/ddb DATE RCVD._
FCUF
'PDR
/b FCAF LPDR WM I6E'REF.i kv MUR SAFEGUARDS OTHER b h()rdpdf FCTC DESI11PTION:
AA' U
'tw w Pw k
& admdL.
-u 1
9
-* - - - ~ - - - - - - - _ _ _ _ _.. _ _ _ _ _ _ _ _,, _,,
ITE
.i
~
q)
Quality Assurance Program for Packaging and Shipment of Radioactive Sealed Source Milan Army Ammunition Plant (MAAP), Milan, Tennessee is a federal facility operated contractually by Martin Marietta Ordnance Systems, Inc.
MAAP is in possession of an Americum 241 sealed radioactive source, 500 mil 11 curies.
The source has been declared excess and remains in On-Site storage.
Storage is covered by NRC byproduct material license number 41-03327-03.
The source is an intregal part of metal probe.
The source was originally a part of an experimental propellant quantity gaging device which was designed by an element of the United States Army and which was shipped (after proper license was obtained) to this plant for experimental development work in connection with the conceived gaging method.
By the time the device was actually delivered, the need for it had deminished. After limited experimental use, the Army directed that the device be retained for possible future re-evaluation.
The probe containing the source was removed and stored in a secure location. More recently the Army decided retention was no longer necessary. The remainder of the device, containing no other radioactive components, has been destroyed. The source has remained in storage for several years, pen.fing disposal efforts. Martin Marietta Ordnance Systems, Inc. (licensee) has arratged for the source to be returned to the supplier, Tyco General Nucleonics. Inc., Pomona, California. Tyco General Nucleonics, Inc. has agreed to receive and assume ownership of the AM-241 source and two each AM-241 reference sources (0.0061 and 0.0438 microcuries). They are to furnish the present licensee a copy of a proper license authorizing possession.
To provide for proper transfer of the source by the licensee to Tyco General Nucleonics, Inc., 2807 Metropolitan PL., Pomona, California 91767, the licensee is submitting the following quality assurance program (plan) for inspecting, packaging, labelling and shipment of the items in accordance with requirements contained in U.S. NRC Rules and Regulations. Title 10, Chapter 1, Code of Federal Regulations, Part 71, Subpart H, Paragraph 71.101(b).
Inspecting Prior to Packaging NRC byproduct materials license number 41-03327-03 requires that the AM-241 500 millicurie sealed source be leaked tested for leakage and/or contamination within six months prior to the date of use or transfer.
The licensee conducted the required leak test on February 26, 1986, using the procedures set forth in application for the present license. The removable contamination was much less than the maximum permitted (0.005 uC1) by NCR regulations.
A copy of the leak test certificate will be forwarded to General Nucleonics.
Surface readings (dose rate) were taken and are shown on Figure I " Shipping Container".
)-
Quality Assurance Program for packaging and Shipment of Radioactive Sealed Source (CONTINUED) u Packaging Method Since the AM-241 source activity exceeds the A2 quantity, the items are to be packaged in a Department of Transportation (DOT) 6M, Type B outer shipping container having a DOT 2R (metal) inner container, both of which were manufactured 2-10-86 by-FBF Nuclear Containers, Knoxville. TN.
(container certification of compliance attached). -The AM-241 source (Figure II attached) is atored in " Shipping Container" (Figure I attached). The Figure I container and the two reference sources will be in the DOT 2R container in accordance with Figure III (attached).
After packaging, the integrity of the containers, locking devices and seal will be assured. Monitoring at the exterior surface and one meter from the surface will be conducted to document the radiation level.
Shipping and Labelling Shipping will be by normal motor freight. The dose rate measured on the Figure I container indicates that the shipping container will require Radioactive White 1 Labels. The source will be shipped as Radioactive Material, N.O.S.
identification number UN2982. Reference DOT Regulations, Part 172.101.
Shipping Papers In addition to other necessary notations on a Bill of Lading, the Bill of Lading will also contain the notation:
RADIOACTIVE MATERIAL, N.O.S.
UN2982 AMERICIUM 241, NORMAL FORM, SOLID ALLOY, ACTIVITY 0.5 CURIES (MAX) PER CONTAINER
. LABEL - RADIOACTIVE WHITE - 1 FISSLE EXEMPT PACKAGE - TYPE B - DOT SPEC 6M WITl! DOT 2R INNER CONTAINER An "OFFSITE RADIOACTIVE SHIPMENT RECORD", FORM MM-673 (blank copy attached) will be properly executed and furnished to the carrier, along with other shipping papers.
Consignee Notification Immediately.upon shipment, the consignee will be notified as to date of shipment, carrier, bill of lading number and any othar pertinent information.
4 9
i--
,v
,.s.
--~.---,._<r
, -.,. ~,
.r-.
.r FBF Nuclear Containers y
g N
Middlebrook Industrial Park = 1201 Hilton Road Knoxville, Tennessee 37921 Farch 1L,1986 Nuclear Containers and Casks for:
TYPE A AND TYPE B CONTAINERS F8F, INC.
Fe a*d'oactrve Mat =aal LSA AND WASTE CONTAINERS 615/584-1868 Reactor Fuel Elemems Waste Matenal Radiossotopes Rad.oactrve Sources Containere and Casks:
Overpacks Refurtustung Et Repaw Drurns 2-R Tubes Cane Fiberboard insutation Benoies insulation Auratone insulation v.rm.cua. insum.on M',73Oc.,,,,,
Certificate of Compliance Lead Products-Lead Pots with Lead Shields Lead 2-R Uners
[g"c",,
Applicable DC':' 6M Specifications, NRC C.uality AssurnEce Regulations:
tead Conta.ners Polyethylene Contoenere for-10 CFR Part 71 Subcart H, Drum Liners ARM Loww L.evel Waste t
.na eiaioons and u
Polyethylene Drume Martin Marietta Ordnance Systems, Inc.
Milan Army Ac=uniticns Plant Milan, Tn 35358 P.O.i J-86-726 for one DCT 6M 1G gal., W/ 4" 2R Ser. No. C50-ce010.
This is to certify that the container manufactured under the above purchase order wss constructed in strict accord with the applicable DCT 6M Specificctions, URC CA Regulations:
10 CFR Part 71 Subpart H, and the Martin Marietta Crdnance Systems, Inc. Purchase order.
Certified by:
N-
.4 p
H. Stringfield, President SERVING THENUCl.EARINDUSTRYFOR OVER 38 YEARS SEND US YOUR PRINTS FOR QUOTATION
4-SURFACE READING (DOSE RATE)
'c 3.000 ' jd
=
CAP INNER
- LEAD -
CONTAINER M ACH SCREW (2)
-LEAD-
,O MREM /HR r.312-
/a i
t
_ AMEN %N 3 i
\\
i n '250'
\\
F///////7///fA a
'V
.250*
A
/
3.375,
/
9.99; MREM /HR /
/
/
/
l.968" 3.062
/
/
/
/
/
t
\\J
/
u
//M h/
250" l
'////
/
/
v
(
/
/
y 1
p' O.02 a
MREM /HR
.375 6 OU 1.G25"p HOUS NG
.250'"
=
OUTER CONTAINER
-STAINLESS STL-SHIPPING CONTAINER NOMI N AL SIZES
FI G.
I
SOURCE / CRYSTAL HOUSING MATL - PIG LEA PER SPEC QQ-L- 171, GR A
- SCALE 2/1-2.250'%
=
=
v h
.250 a
I l
2.187 I
o ANNULAR 187 3
N ERICIUM 241 N
a
'NN SOURCE
)
AMERSHAM [SEARLE A
NN Fyf4 AMCK 94G
- 860 %
=
~ I.020 $
=
1.340 %~
=
1.485%
=
=
FI G II
METAL TOP FIBER FILLER 1
f//X/////////////)
y n
k\\\\\\\\\\\\\\\\\\ k/
k
'//
/b COMPONENT
/
/f CAVITY 3,,
ifDIAX If' DP 3
~
4 FIBER FILLER m
s::
N D
FIBER FILLER q
4:
- W
%?
SHIPPING hh
/l 2
j/
FISER FILLER
'[
///f{
q
,-///-
METAL CAN
- 3 f" -+
,7" s
og INTERMEDIATE SHIPPING CONTAINER DOT 2R SCALE:
I /2" = l" FIGURE 1i
14" %
=
=
{ RING LID CLAM LID i
FIBER FILLER '
(
/
\\
N
\\
(4 CS
\\
i g,,
-FIBER FILLER
/
FIBER FILLER 4
/
T I
/xNNWNAW 2"
1 FIBER FILLER i
OUTER AN hbTER
~ 5 f'@ +
INTERMEDIATE b
I ER 13 f,,0 (DOT 2R)
=
D0T 6M SHIPPING CONTAINER SCALE:
1/4"=I" FIGURE TV
i'
,s.
e MA M TEN MA M#E TTA OFFSITE RADIOACTIVE SHIPMENT RECORD mamim mamism atumswum satas use.
' matAm. temmesese asses MATERIAL RE(UIRES:
SPECIFIC LICE!;SE GENERAL LICENSE ORIGINATOR COMPLETE DESCRIPTION OF CUhTENTS (IhCLUDE DETAILED PACKAGING DESCRIPIloh:
QUALTITY AhD SHIPPlhG DESCRIPTION):
EXEMPT FROM D.O.T. PACKAGING YES hu Al4D LABELlhG REQUIREMENTS Sh1P 10:
(ConFLETE ShlPPlhG ADDRESS)
ORIG. CNTR. ACCEPTABILITY DOCUMENTED:
O CNTR. EXAMINED:
NO EVIDENCE OF DAMAGE O
OR DETERIOKATlON RECIPIEhTS AUTHORIZATION TO RECEIVE MATERIAL SPECIFIC LICENSE NO:
th0SS LU. OF ChTR. SPtc. UK TufAL CURIES VERIFICATION:
O COPY OF LICENSE ON Fil.E WT.
ChihS.
SPtGIAL Pt.h. 14 0.
O OriiER - DESCRIBE MAX. CURIES /CNTR.
AUTl!OR17.ED BY GENERAL LICENbE SPEllAL REVIt.WS hryUlkED /shD COMPLitu Willi:
SHIP VIA:
O MOTOR FREIGill
[ RAIL O hohl ueS oOmR RADIATION MONITOR 1hG AhD CERTIFICATION SUh1 ACE DuSE PSIL-DOSL RATE 3 ET F ROM SMEARS OF UUTER CONTAINER:
RADIATION SURFACE OF PACKAGE:
SURVEY O <o.5 natallis ua O <0. -> Maul /hk OR O(2200UR eme-r/toO SQ CM NO:
Ite /LR MRul/IIR gg
( 200 OR daCZ/ LOU SQ CM ALDITIUNAL DATA AND lhSTRl;CTIOhS:
(lhCLUDlhG READINGS OR INTEkhAL PACKAGING)
I PAta Po ttT l MNI LKI AI, DUT RADIDAC11VE LABEL,S APPLIED TRAhSPOkl GFOLP FORM W U 1'! E Y E L1,0W 11 YhLLOW 111 huht THib SillPHiM hLill S ALL APPLICABLL P EDI.RAI, REGULAT IOhS A!.D RhyUlkl.MEf.'IS FOR Ti1E PACRAGlhG AND MAPfihG FUK 1:AhlvACTIVE MATLhl ALS.
S I Gh AT U R E..
DATE:
I l
TIME:
1 rih-L ! d (3-60) b
r krA R TIN. MA RIETTA PURCHASE ORDER Cal.RTIN MAtlETT4 OKON1NCE SYSTEMS. INC.
MILAN FKMY AWMUNITION PLANT MILE.M. ftNMES$tt 38358 TELEP NE: (901) 686-6101 22937 Date 4/4/86 U.S. NUCLEAR REGULATORY COMMISSION Ship Via REGION ll, NUCLEAR MATERIALS SAFETY SECTl( N F. O. D.
101 MARIETTA ST. SUITE 2900 Terms ATLANTA, GA 30323 Denver To j
3 TENN SALES TAX g
Tanable O Not Taxabte 2O(
DELIVERY SCHEDULE:
NO C.O.D. SHIPMENT WILL BE ACCEPTED PLEASE RENDER INVOICES IN DUPLICATE A
B C
b l_
uARK acB NO. AND PURCHASE CROER NO ON E ACH PACKAGE. PACKtNG :> LIP AND INVOICE TO INSURE PROVPT PAtt.*E NT 00 7M M
M1
@ 00 ITEM OUANTITY DESCRIPTION PRICE EXTENSION Fee for evaluation of Part 71 Quality Assurance Program 150.00 Application for Packaging and Shipment of Radioactive Scaled Source.
S/N C57-72005
(
DAAM9 77.CM THE PURCf.TF ORDER R'sTED
.b -C 7 E5 F A " ~ ';T min r n.< q m,t f
(L 5.
5.
2 A..
i
'. l i i
>r-s 0.' i
.. i r; '
l ATTA:HED 15 OUR CHECK NO. 09740 IN THE D TO 't b '
,cc N1 i
AMOU 1T OF $150.00 IN PAYMENT OF THE ABOVE ORDE 1.
THIS ORDER IS BEING SENT IN R'MONT!!ACTOI6 0; tii, ai g DUPLICATE SO YOI) MAY SIGN CARBON COPY ACKf0WLEDGING R ECEIPT OF OUR CHECK NO.
0974L CC 10/1-0-0-0 The permrs5;D:e vana00n unde' the clause Of ("9 generd! Drov'sror's entSed The ench^f,ed (pnerd' Terr"5 and Cond bons of Sale and any addend Va'ta!Cr) in QLantity Sha'l be brNed !O a"'u*d Pere'O rire maae a part of this order to which seher agre*S by aCCPpf ancef"ait774f RONANcE SYSTEMS tNs O' der M
A Increase 0
B. Decrease _ _ 0 _-.__ _ %
. INC.
ugnrin
/
Approved B/-
/
Buyer 4
/
g -[ [#
ay __
e'UNCHASING AGE NT Controher
- ~ *.
-~
ORIGINAL
,u
" "?'.'.' ?-.
?
?
^
^
J
PURCHASE ORDER MARTIN MARIETTA ORD NCE SYSTEMS. INC.
M A.AN Att'
$8UNITION PLANT a
MfLAN. TENN Sit 383SS PURCHASE ORDER NO. T-86-891 TELEPHONE: (901) 686 6101 22937 Date 4/4/86 U.S. HUCLEAR REGULATORY COMISSION Ship via REGION !!, NUCLEAR MATERI ALS SAFETY SECTIC N F. o. B.
101 HARIETTA ST. SUITE 2900 Terms ATLANTA, GA 30323 Deiiver To
_.6 O
TENN SALES TAX k
Taxable G Not Taxable JO(
4 DELIVERY SCHEDULE:
CostCODE NO C.O D. SHIPMENT WILL BE ACCEPTED PLEASE RENDER INVOICES IN DUPLICATE A
B C
~ D E
MARK JC8 NO. AND PUROHASE CROER NO ON EACH PACKAGE PACNNG SUP AND INVOICE TO 1NSURE PROMPT PAWENT-0 U4 MI ITEM QUANTITY DESCRIPTION PRICE EXTENSION Fee for evaluation of Part 71 Qt.ality Assurance Program 150.00 Application for Packaging and Shipment of Radioactive Sealed Source.
S/N C57-72005 DAAAE77.C-4032 THIS PURCl!ASE ORDER RATED 00 C 7 THB IS A DEFE" ' R \\TED ORPER AND YOU A7~ ~~
i'E0:
't' T 'E TRO.
'I 3. ' :
~ Z AT3 A
1 e
il m
- i
- n 0,c
m7
! l.' 3 '!. '
D
- [.
s
/.
' ' " ' 10 ;.
"gi rr 3ag;g ATTA ;HED i5 0UR CHECK H0. 09740 IN THE O F T.', ' ),!! 'C;n ;; o "g,
',N,,,,"
AMOU ST OF $150.00 IN PAYMENT OF THE ABOVE I DI AI U CC'NU fl.;il ORDE 1.
THIS ORDER 15 BElHG SENT IN DUPL ICATE SO YOU HAY SIGN CARBON COPY LUil CO:iillACTOT:5 0i' Tii!5 hATim
(.C Kli')WLEDGING RF CEIPT OF OUR CHECK NO.
0974 ).
a CC 10/1-0-0-0 WE ACKNOWLEDGE RECEIPT OF THE ABOVE ORDER AND HEREDY The enc!osed Geneva! Terms and Conetons of See and any adderE AGREE TO THE TERMS THEREOF.
a'hsed tr oreto are made a part of th!s order to which terer ayens by acc+vance M t% order MARTIN RIE RDNANCE SYSTWS, INC.
DATE COMPANY
~
/y PURCHASING AGE NT BY ACKNOWLEDGMENT ACKNOWLEDGMENT FAUST BE SIGNED AND RETURNED WITHIN TEN (10) DAYG u u s aev i,