ML20203N740

From kanterella
Jump to navigation Jump to search
Application for Amend 151 to License DPR-54,changing Tech Specs to Reflect Limiting Conditions & Surveillance Stds of STS & Revised Model Tech Spec for Snubbers,Per Generic Ltr 84-13.NSHC & Description of Changes Encl.Fee Paid
ML20203N740
Person / Time
Site: Rancho Seco
Issue date: 10/08/1986
From: Julie Ward
SACRAMENTO MUNICIPAL UTILITY DISTRICT
To: Miraglia F
Office of Nuclear Reactor Regulation
Shared Package
ML20203N741 List:
References
GL-84-13, JEW-86-461, NUDOCS 8610200003
Download: ML20203N740 (5)


Text

'

e

  1. $ SMUD SACRAMENTO MUNICIPAL UTILITY DISTRICT : ' 62o1 S Street, P.O. Box 15830, Sacramento CA 05852-1830.(916)452-3211 AN ELECTRIC SYSTEM SERVING THE HEART OF CALIFORNIA JEW 86-461 October 8,1986 DIRECTOR OF NUCLEAR REACTOR REGULATION ATTENTION FRANK J MIRAGLIA DIRECTOR PWR-B DIVISION U S NUCLEAR REGULATORY COMMISSION WASHINGTON DC 20555 DOCKET N0. 50-312 LICENSE N0. DPR-54 PROPOSED AMENDMENT NO. 151 In accordance with 10 CFR 50.90, the Sacramento Municipal Utility District proposes to amend its Operating License DPR-54 for. Rancho Seco Nuclear Generating Station Unit No. 1.

Proposed Amendment No. 151 implements the provisions of Generic Letter 84-13 (May 3, 1984) which states that "a licensee may choose to request a specific license amendment to delete the tabular listing of snubbers from its technical specifications." Concurrently, relevant changes are made in the Rancho Seco Technical Specifications for wording consistency with the LC0 and Surveillance Standards of the Standard Technical Specifications and the Revised Model Technical Specification for Snubbers enclosed with the generic letter.

In addition, the Snubber Seal Replacement Program and the specific snubbers included in this program have been deleted. This constitutes the District's withdrawal from the relief given by the NRC in Amendment No. 77.

The Snubber Seal Replacement Program is replaced by Snubber Service Life Monitoring. Also, an action statement is added specifying 10 CFR 50.59 safety analyses for chancjes resulting in snubber quantities, types or locations. The changes in this proposed amendment are discussed in detail in Attachments I, II and III, which are the Safety Analysis, "No Significant Hazards" Evaluation and Description of Proposed Changes, respectively.

Pursuant to 10 CFR 50.91(b)(1), the Radiological Health Branch of the California State Department of Health Services has been informed of this proposed amendment by mailed copy of this submittal.

Enclosed is a check in the amount of $150.00 as required by 10 CFR 170.21,

" Schedule of Fees."

\\

8610200003 861008 DR ADOCK 05000312

\\

PDR Y$5W

Proposed Amendment #151 October 8, 1986 Should you require any further information with respect to this Proposed Amendment, please contact Mr. Ronald W. Colombo at Rancho Seco Nuclear Generating Station Unit No. 1.

. WARD Subscribed and sworp to before me DEPUTY GENERAL MANAGER, this @t" day of U c tea gg 1986 NUCLEAR q)

YOIDn boh I%G Attachments Notary Public

^

cc: Region V (2)

MIPC'(2) t 3m INP0 DAWN DARUNG HOTARY PU3UC-CALVORNIA SACRAMENTO COUNTY My Comm. Empires Ja.s 12,1990

ATTACIMENT I SAFETY ANALYSIS Pursuant to the provisions of Generic Letter 84-13 (May 3, 1984), Proposed Amendment No. 151 deletes the tabular listing of snubbers required to be operational in Table 3.12-1 of the Rancho Seco Technical Specifications, and those only to be functionally tested as part of the Snubber Seal Replacement Program listed in Table 4.14-1.

Deletion of the latter table and of Specification 4.14e, Snubber Seal Replacement Program constitutes the District's withdrawal of the relief given by the NRC in Amendment No.

77.

The proposed amendment modifies Specifications 3.12 and 4.14 for consistency with the wording of the Revised Model Technical Specifications for Snubbers enclosed with GL 84-13 while retaining plant specific wording of the Rancho Seco Technical Specifications.

An action statement is added to Specification 3.12 which allows restoration of system operability by removal of an inoperable snubber (s) and performance of appropriate analyses pursuant to 10 CFR 50.59 for snubber modifications.

This added action statement is in accord with provisions of GL 84-13.

Specification 4.14e, Mechanical. Snubber Functional Test Acceptance Criteria is added using the wording provided in the Revised Model Technical Specifi-

-cations for Snubbers, as is Specification 4.14f, Snubber Service Life Monitoring.

The District has reviewed this proposed amendment and concluded that while continuing to minimize personnel exposure and risks to personnel safety, the changes would not reduce the availability of those snubbers which are needed to ensu~re that structural integrity of supported systems is main-tained during and following a seismic event or other conditions of dynamic loading. Thus, the proposed amendment is judged as not involving an unreviewed safety question, and safety of the plant or the public is not endanged.

ATTACHMENT II "N0 SIGNIFICANT HAZARDS" EVALUATION Proposed Amendment No. 151 implements the provisions of Generic Letter 84-13 (May 3, 1984) which states that "a licensee may choose to request

-a specific license amendment to delete the tabular listing of snubbers from its technical specifications." Concurrently, relevant changes are made in the Rancho Seco Technical Specifications for wording consistency with the LC0 and Surveillance Standards of the Standard Technical Spec-ifications and the Revised Model Technical Specifications for Snubbers enclosed with the generic letter.

The District has evaluated the proposed amendment against the criteria of 1'0 CFR 50.92, namely that the proposed changes would not:

1.

Involve a significant increase in the probability of an accident previously evaluated; or 2.

create the possibility of a new or different kind of accident from any accident previously evaluated; or 3.

involve a significant reduction in a margin of safety.

The proposed amendment does not involve a change in the configuration of Rancho Seco. Thus, it does not increase the probability or consequences of an accident, nor does it introduce the possibility of a new or different kind of accident previously evaluated.

The District has concluded that the deletion of snubber listings from the Rancho Seco Technical Specifications would not alter the scope or type of testing required, nor change the operability requirements for applicable snubbers.

It should also be noted that record _ keeping requirements have been added as Specification 4.1.4f for consistency with the Standa'rd Technical Specifications. Thus, a reduction in the margin of safety is precluded by this specified Snubber Service Life Monitoring.

On the basis of the above evaluation, and because this proposed amendment is an implementation of recommendations given by the NRC in Generic Letter 84-13, the District concludes that the proposed changes do not involve a significant hazards consideration.

i

~ -,.

.c

~,

ATTACHMENT III DESCRIPTION OF PROPOSED CHANGES 1.

List of Tables, page ix:

Table 3.12-1, Satety Related Hydraulic Snubbers is shown as:

"This table has been deleted."

2.

List of Tables, page ix: Table 4.14-1, Designated Safety Related Hydraulic Snubbers Functionally Tested Only as Required by the Snubber Seal Replacement Program is shown as:

"This table has been deleted."

3.

Specification 3.12, page 3-51: The introductory paragraph, SNUBBERS, has been rewritten to incorporate the wording of the Revised Model Technical Specifications for Snubbers.

4 Specification 3.12, page 3-51: The existing action statement was divided into two separate actions (1. and 2.), and a third action (3.) statement was added spec'?ying 10 CFR 50.59 requirements.

5.

Specificatior 3.12, page 3-51:

Deleted last three words of Bases:

"during reactor operation" to make it clear than the snubbers are needed to be operable during all reactor modes.

6.

Table 3.12-1. pages 3-51a: Deleted snubber lists and added:

" Table 3.12-1 has been deleted, and pages 3-51b through e completely removed."

7.

Table 3.12-1, pages 3-51 through 3-51e:

Physically removed these pages.

8.

Specification 4.14a, page 4-47: Deleted reference to Table 3.12-1.

9.

Specification 4.14b, page 4-47a: Added reference to Specification 4.14e in top paragraph.

10.

Specification 4.14c, page 4-47a:

In first paragraph added:

(mechanical or hydraulic); reference to Specification 4.14e; and:

(mechanical and hydraulic).

11. Specification 4.14c, page 4-47a:

In second paragraph deleted reference to Table 3.12-1, and deleted last two sentences which are redundant with the wording in the fourth and first paragraphs, respectively, of Specificatiom 4.14c.

12. Specification 4.14e, page 4-47b:

'001J Specification 4.14e, Mechanical Snubber Functional Test Acceptast' Cr eria in its entirety, replacing Snubber Seal Replacement Pronrc

=h1 was entirely removed.

13.

Specification 4.14f, page 4-4/b: Adaed Specification 4.14f, Snubber Service Life Monitoring in its entirety.

14.

Specification 4.14f, page 4-47c: Added last paragraph of Specification 4.14f to top of page.

15. Table 4.14-1, page 4-47d:

Deleted snubber list, and added:

"This table has been deleted."

16. Table 4.14-1 (continued), page 4-47e:

This table has been deleted, and the page physically removed.

17.

Specification 4.14. Bases: Made new page, 4-47d, and added last three paragraphs.