Text

,

i f's i

e 1

Westinghouse Electric Corporation Nuclear Energ/ Systems Application for Renewal of the C>xtificate of Ocznpliance for the ROC ihipping Cantainers Package Identification Number USA /5450/AF

)

C+ w 0+r 20, 1985 April 28, 1986 (Revision 1)

July 1,1986 (Revision 2)

U. S. Nuclear Regulatory h 4=aion Docket 71-5450 8608050335 860701 DR ADOCK 07105450 PDR

f REVISICW REwku 1

REVISION DATE OF PAGES NUMBER REVISION REVISED REVISION REASON 1

4/28/86 1,11 Revised Table of Contents 1

4/28/86 4,10,11,16 Correction of typographical errors 1

4/28/86 4

Revised reference to drawing 1

4/28/86 9,10 Revised analysis for normal conditions of transport to reflect requis.w.umitus of 10CFR71.71 1

4/28/86 17,18,19 Revired Section 4.0, Procedural Controls 1

4/28/86 AtM @mant 8, Changed references All Pages to drawings 1

4/28/86 At%"hmant 12 Added drawings 1

4/28/86 18-4 & 18-5 Corrected errors 8 in Table.

1 4/28/86 19-1 to 19-8, Revisad nuclear 19-32 criticality safety Added pages analysis to incor-19-42.1 thru porate additional 19-42.9 calculations to 9 support finite array accident analysis.

1 4/28/86 2, Added procedures for All Pages operation and maintenance 1

4/28/86 3, Added procedures for All Pages Quality Control Inspection 2

7/1/86 10 Revised Section 2.6 for canpression test requiremsats.

2 7/1/86 2 Revised and added drawings.

Docket No. 71-5450 Initial Subnittal Date: 12/20/85 Page No. 11 Revision Subnittal Date: 7/1/A6 Rev. No._.2_

't

t 7.

Corner Drop - Not applicable to RCC containers.

8.

Penetration - For the conditions specified, the j

projectile does not Iwaaae sufficient energy to pemkate or deform the shall of the ROC shipping containers. 'Iherefore, the effect of this incident is negligible.

9.

Coupression - For the conditions specified, the ROC container shells will not experience any deformation which would serve to re v= the spacing between pairs of fuel amammhlies. 'Iherefore these conditions will have no adverse effect on the Roc containers. (See Attachments 5, 6, 13, and 14)

I 2.7 2.7.1 ROC Container

'Ihe accident conditions specified in Part 71 will not I

credibly produce an arrangement more reactive than that analyzed under General Criticality Standards. 'Ihe clearance between the massive vertical member of the internal ocuponents and the shell of the container will be such that a fuel assembly will not pass. Any crushing

)

due to the Accident Free Drop would only decrease the clearance. It is not credible that the effectiveness of the neutron absorber material, when used, will be I

appreciably reduced as the result of the Accident Free Drop, due to its location within the massive vertical member. 'Ihe necessity for evaluating the Accident l,

Puncture and Water Innersion conditions is obviated by the==='= tion of =vNm moderation and full reflection. 'Ihe necessity for evaluating an Accident

'Ihermal condition is obviated by the limitation of the contents to clad fuel assemblies, j

Docket No. 71-5450 Initial Subnittal Date:

12/20/85 Page No. 10 Revision Subnittal Date:

7/1/86 Rev. No. 2 4

r

ATTACHMENT TO IEITER DATED 7/1/86 INSTRUCFIONS FOR REPIJCEMENT OF DRANINGS IN ATTACHMENT 12 Old Drawinct Number Replace with New Drawinct Ntaber SEE-85002, Sub 2 SKE-85002, Sub 3 SEE-85003, Sub 2 SKE-85003, Sub 3 SKE-85004, Sht 1, Sub 2 SKE-85004, Sht 1, Sub 3 SEE-86003, Sht 2 SKE-86003, Sub 1 SEE-86004, Sub 2 SEE-86004, Sub 3 SED-86007, Sub 2 SED-86007, Sub 3 SKD-86008, Sht 1 BRD-86008, Sht 1, Rav 2 SED-86008, Sht 2 SED-86008, Sht 2, Rev 2 SED-86008, Sht 3 SED-86008, Sht 3, Rav 2 BRD-86009 SED-86009, Sub 2 SED-86010 SED-86010, Sub 2 SED-86011 SED-86011, Sub 2 l

SKD-86012 SED-86012, Sub 2 SKC-86019 SKC-86020, Sht 1 SKC-86020, Sht 2 SRC-86021, Sht 1 SKC-86021, Sht 2 i

  • These are new drawings not included in prior transmittal.

i 1

1

.,,..m_,-,.,.

OVERSIZE DOCUMENT PAGE PULLED SEE APERTURE CARDS NUMBER OF PAGES: O ACCESSION NUMBER (5):

ROQ2OSn6VO

% 0 5'O S O S 7 0 3V7 312 -

i 8W 979 3 Wo 37(a 35Y 272 36G 329=

369 92&

34/)

939 flo GL.

3(oY scao 3(o9 APERTURE CARD /HARD COPY AVAILABLE FROM RECORD SERVICES BRANCH,TfDC FT5 492-8989

.