MaineYankee P.O. BOX 408

  • WISCASSET, MAINE 04s78 + (207) 882 6321 February 24,1998 MN-98-13 GAZ-98-11 UNITED STATES NUCLEAR REGULATORY COMMISSION Attention: Document Control Desk Washington,DC 20555

References:

(a)

License No. DPR-36 (Dockit No. 50-329)

(b)

Letter to MYAPC from USNilC, Fitness for Duty Programs (10 CFR 26) for Maine Yankee Atomic Power Station, dated January 12,1998

Subject:

Fitness For-Duty Performance Data Gentlemen:

Enclosed is the Fitness-For Duty Program Performance Data for Maine Yankee for the six month

.eporting period July 01,1997 to December 31,1997. This data is submitted pursuant to the requirements of 10 CFR 26.71(d). Since Part 26 no longer applies to Maine Yankee, Reference (b),

this is our last report submitted in accordance with that regulation.

Should you have any questions on the enclosed material, please contact us.

Very truly yours, a

~

(f

/

George A. Zinke, Dire Nuclear Safety & Regulatory Affairs GAZ.~mwf Enclosure i

h I

c: Mr. Hubert J. Miller Mr. Ron Bellamy Mr. R!rhard J. Rasmussen =

Mr. Michael K. Webb Mr. F.. Destie -

Mr. Michael T. Masnik Mr. Clough Toppan

'dUVU gggg Mr. Uldis Vanags -

....c 9803030138 980224 i

PDR-ADOCK 05000309 R

PDR;.

FITNE53 FOR DUTY AT MAINE YANKEE A HEALTH AND SAFETY PROGRAM "To provide for a safe, drug and alcohol free workplace" Semi-Annual Report July 1,1997 - December 31,1997 10CFR26 performance Data repod for Maine Yankee Atomic Power Company i

J

p.

Maine Yankee Fitness For Duty Semi-Annual Report July 1,1997 - December 31,1997 Table of Contents Page 1.

Performance Data (NUMARC format)................................................. 2 2.

Summary of Management Actions I.

I n i ti a t i ve s.................................................................................

II.

Administrative Action.............................................................3 Ill.

Le s sons Learn e d....................................................................... 3 IV.

Effectiveness Evaluation............................................................ 3 V.

Report able Eve nt s...................................................................... 3 3.

Graphic Analysis Tests by category for July 1,1997-December 31,1997........................ 4 Tests by category for January 3,1990 - December 31,1997................. 5 4.

Random Test Rates January 1,1997 - December 31,1997................... 6 5.

Random Testing Frequency January 1,1997 - December 31,997.......... 7 6.

Confirmed Positive Tests by Category and Substance........................... 8 July 1,1997 - December 31,1997 7.

Confirmed Positive Tests by Category and Subatance........................... 9 January 1,1997 - December 31,1997

(

Fitness for Duty Program Performance Data Personnel Subject to 10CFR26 Maine Yankee Atomic Power Comoany December 31.1997 wn o~

Ballev Point. Ferry Road. PO Box 408. Wiscasset ME 04578 Herbert E. Torbera Jr.

(207) 882-5310 mm mm. m Cutoffs: Screen / Confirmation (ng/ml) e Appendix A to 10CFR23 Marijuana

/

Amphetamines

/

/

Cocaine

/

Phencycliaine

/

/

Opiates

/

Alcohol (%BAC)

/

/

Testing Results Licensee Long-Term Short-Term Employees Contractor Contactor Personnel Personnel

/c erage Number with 425.1 - total Unescorted Access includes MY 119 574.8 Employees Categorios

(

Tested Positive Tested Positive Tested Positive Pre-Access 1

0 3

0 168 1

For Post Accident 0

0 0

0 0

0 Cause Observed Behavior 0

0 0

0 1

0 Random 95 0

39 0

117 1

Follow-uo 7

0 0

0 0

0 Other 12 0

0 0

11 0

Total 115 0

42 0

297 2

Rev.1/92 2

I

SUMMARY

OF MANAGEMENT ACTIONS 1.

Initiatives Taken The following list is a synopsis of initiatives by Maine Yankee:

September performed annual audit of California PharmChem Laboratories Attended Region i Fitness For Duty Administrators Meeting 4

ll.

Administrative Action Ons For Cause and one Random Long Term Contractor positives.

November 1997, Maine Yankee submitted a letter to the NRC, advising the position that 10CFR26 no longer applied to Maine Yankee.

Maine Yankee commits to continue with a Fitness for Duty program, though not 4,

to the level of 10CFR26 111.

Lessons Learned No new lessons learned.

IV.

Effectiveness Evaluation The Maine Yankee FF0 program continued to effectively meet both the requirements and intent of 10CFR26. The flexibility of the program enhances the company's ability to effectively ensure the safety of employees and to emphasize the importance of the FFD program.

V.

Reportable Events During the period of July 1,1997 - December 31,1997, no reportable events occurred.

i 3

.......__.__m_..

I i

MAINE YANI;EE FITNESS FOR DUTY i

NUMBER OF TESTS BY CATEGORY Pro-Access -

m 172 i

For Cause -

t

[

Post Accident -

i

?

i Random -

25:

m-i t

i Follow-up -

7 TOTAL OF TESKS : 454 Jah 1,1997 - December 31,1997 f

Other -

i

)

O SO 100 150 200 250 300 i

4

MAINE YANKEE FITNESS FOR DUTY j

NUMBER OF TESTS BY CATEGORY i

Pre-Access -

3786 73 Positive l

For Cause -

i p 59 t

26 Positive Post Accident -

o I

Rar. dom -

6284 i

13 Positive i

Follow-up -

E 152 1 Positive TOTAL OF TESTS: 16.052 Jassary 3.1990 - Decoaler 31.1997 i

f OvereII Positive Test Raas : 0.704 %

78I O

2000 4000 6000 8000 10000 1

I 5

)

i a

i

l MAINE YANKEE (MY) FITNESS FOR DUTY RANDOM TESTING RATES Janur.ry 1,1997 - December 31,1997 The following report is based on FFD performance data for the total Maine Yankee population and personnel granted unescorted access to Maine Yankee. This report includes the current percentages of personnel tested.

TOTAL TOTAL YTD PLANT PLANT TOTAL TOTAL DRAWN TIMES AVG.

BADGE BADGE MY MY FROM DRAWN POPULA-POPULA-POPULA-TION TION TESTED TION TESTED TESTED TESTED LICENSEE EMPLOYEES (Total Population)

CuwM (:iicugh 45,484 107 425.1

' 58 62.3 %

261 61.4 %

2 Desunber 31,1997 STC PERSONNEL Current through 88,523 154 574.8 327 56.9 %

December 1997 LTC PERSONNEL Current through 8,095 68 119 74 62.2 %

December 1997 6

d MAINE YANKEE (MY) FITNESS FOR DUTY RANDOM TEST FREQUENCY January 1,1997 to December 31,1997 MAINE YANKEE PERSONNEL YEAR TO DATE 1997 TOTAL TOTAL IIOLIDAY' SUN MON TUES WED TliUR FRI SAT DAYS PERSONNEL SE!ICTED SELECTED 2

A.M.

4 12 11 9

9 10 4

59 136 i

P.M.

4 10 6

10 9

5 4

48 121 3

TOTAL 8

22 17 19 18 15 8

107 257 STC PERSONNEL YEAR TO DATE 1997 TOTAL TOTAL llOLIDAY' SUN MON TUES WED TIIUR FRI Sr.T DAYS PERSONNEL SELECTED SE!ICTED 3

A.M.

4 17 17 13 12 16 4

1:3 173 1

P.M.

4 12 12 15 13 9

4 69 154 4

TOTAL, 8

27 29 28 25 25 8

152 327 LTC PERSONNEL YEAR TO DATE 1997 TOTAL TOTAL I!OLIDAY' SUN MON TUES WED TIIUR FRI SAT DAYS PERSONNEL SEIICTED SELECTED 2

A.M.

4 6

7 6

3 8

4 38 40 1

P.M.

3 7

4 3

6 2

4 30 34 3

TOTAL 7

13 11 9

9 10 8

68 74

  • holidays are included in totals.

STC: Short Term Contractor

~

LTC: Long Term Contractor 7

j-n o

o O-m p

j 1

f-

]g o

h,y f fj *, "

2a

}

a j

y 1

IH1 113

MAINE YANKEE FITNESS FOR DUTY CONFIRMED POSITIVE TESTS BY CATEGORY AND SUBSTANCE JANUARY 3,1990 - DECEMBER 31,1997 Licensee -

For Cause -

Alcohol (2)

Random -

Alcohol (1)

Random -

Marijuana (3)

Follow-up -

Marijuana (1)

Long Term contractor - Random - Marijuana (1)

Short Term Contractor - Pre-Access - Alcohol (8)

Marijuana (50)

Cocaine (15)

Opiate (1)

Short Term Contractor - Random -

Cocaine (1)

Marijuana (6)

Alcohol (1)

Short Term Contractor - For Cause -

Cocaine (1)

Marijuana (6)

Alcohol (19)

Positive Substance Total-116*

Positive Test Total-113 Total Tests Completed - 16,052

  • (Individuals have tested positive for more than one (1) substance) 9 4