}l-f9YG

~

m.231986 anurdiTO FCTC: RHO, g, g3ghh 71-5942 390-SS General Electric Company ATTN: Mr. G. E. Cunningham

'Vallecitos Nuclear Center Pleasanton, CA 94566 Gentlemen:

This refers to your application dated February 28, 1986, as supplemented, requesting an amendment to the Model No. 700 yackage, In connection with our review, w need the information identified in the

'r

"' enclosure to this letter.

Please advise us within 30 days from the date of this letter when this information will be provided. The additional information requested by this letter should be submitted in the form of revised pages.

If you have any questions regarding this matter, we would be pleased to meet with you and your staff.

Sincerely.

0-p@ t,. Y Charles E. HacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety. HMSS

Enclosure:

As stated Distribution: w/ encl Docket File NRC PDR IE HQ Region V RH0degaarden (2)

HWLee NMSS R/F 8608040021 860723 PDR ADOCK 07105942 FCTC R/F C

PDR CEtp dha rnS 4

.Q _.

h kelb

'4 TG

")fEMidD5riali " @ dIjo m

'L FCTC FCTC

/

a,mox4H dEg55rdEn: din"isiiE' "U7][/55" "d7{755" "6

85' chk

^

on.-

- Nnc ronu ps 00-89 nacu ono,

OFFICIAL RECORD COPY

d General Electric Company f9odel No. 700 Package Docket No. 71-5942 Enc 1 to 1tr dtd:

STRUCTURAL 1.

For location 1 Welds, show that the finite element model satisfies the equilibrium condition based on the applied loads and the resultant forces at nodal points 1 and 13.

2.

For location 3 Welds, the configuration for the weld evaluation is not satisfactory. The intermittent fillet welds are effective in resisting direct shear forces only. They are not effective in resisting rotation and the tear due to plate bending. Revise the application to take these concerns into consideration.

OPERATING PROCEDURES 1.

Step 8.kk. should cite 10 CFR $71.87(i) rather than $71.87(h).

2 Pages 8 and 9 should show a revision nurt>er other than "0" to indicate they have been revised.

OF FICE )

DATE)

NRC FORM 318 (1080) NRCM O240 OFFICIAL RECORD COPY