ML20203E447

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 70-7001/97-11 on 971008-1124 & Nov. Violations Are of Concern Since Violations Indicate Lapses in Attention to Detail Applied to Licensee Processes for Determinining Event Reportability & Developing Analyses
ML20203E447
Person / Time
Site: Paducah Gaseous Diffusion Plant
Issue date: 12/09/1997
From: Hiland P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: John Miller
UNITED STATES ENRICHMENT CORP. (USEC)
Shared Package
ML20203E451 List:
References
70-7001-97-11, NUDOCS 9712170065
Download: ML20203E447 (2)


See also: IR 07100008/2011024

Text

.

--

.

-

- . .... - . - .. . - . - - -

.

.

.

-

-*

_,

l

l'

December 9, 1997

i

)

y

,

)

Mr. J. H. Miller

Vice President - Production

United States Endchment Corporation

Two Democracy Center

6903 Rocidedge Drive

Bethesda, MD 20817

,

i

SUBJECT:

NRC INSPECTION REPORT 70 7001/97011(DNMS)'

AND NOTICE OF VIOLATION

i

Dear Mr. Miller.

On November 24,1997, the NRO completed a routine resident inspection at your Paducah

Gaseous Diffusion Plant. The enclosed report presents the results of the inspection. During the

six week period covered by the inspection report, the conduct of activities at the Paducah

'

Gaseous Diffusion Plant were generally adequate.

Based upon the results of the inspections, the NRC *.as determined that violations of NRC

requirements occurred. The violations are cited in the enclosed Notice of Volation (Notice) and

the circumstances surrounding them are described in detail in the enclosed report. The

violations are of concem because they indicate lapses in the attention to detail applied to your

processes for determining event reportability and developing and approving nuclear criticality

safety analyses.

.

You are required to respond to this letter and should follow the instructions specifed in the

enclosed Notice when preparing your response. The NRC will use your response, in part, to

determine whether further enforcement action is necessary to ensure compliance with regulatory

requirements,

in accordance with 10 CFR 2.790 of the NRC's " Rules of Practice" a copy of this letter, its

enclosures, and your response will be placed in the NRC Public Document Room (PDR).

I

\\

}

l

9712170065 971209

PDR

ADOCK 07007001

)

C

PDR

a

ll I.lll.lill.Li.l11. ll.ll.l

.

-

-

-

-

.

-

-

- .

- _.

. - - -

_

--

'

O

'

J. Meller

2

We will gladly discuss any questions you have concoming these observations.

Sincerely,

Criginal Signed by

Patrick L Hiland, Chief

Fuel 4de Branch

Docket No.

70 7001

Enclosures:

1. Notice of Violation

2. In::pection Report

No. 70-7001/g7011(DNMS)

cc w/ ends: ' S. A. Polston, Paducah General Manaper

W. E. Sykes, Paducah Regulatory Affal.s Manager

J. Morgan, Portsmouth Acting General Manager

C. A. Toolle, Manager, Nudear Regulatory

Assurance and Policy, USEC

Paducah Resident inspector Office

Portsmouth Resident inspector Office

J. C. Hodges, Paducah Site Manager, DOE

bec w/encis: R. Pierson, NMSS

P. Tir J, NMSS

W. Schwink, NMSS

P. Harich, NMSS

M. L Hom, Project Manager-Paducah, NMSS

R. Bellamy, RI

E. McAlpine, Ril

J. Caldwell, Rlli

F. Wens!swski, RIV/WCFO

PUBUC IE07

'

DOCUMENT NAME: G:\\SEC\\PADg7011.DNM

To receive a copy af this -A-r_.

. A indicate in the boa:"C" = copy without enclosure T= Copy with enclosure"We No copy

OFFICE

Rlli

l fd

l

l

l

NAME

Hiland:ib 9A4

OATE

mlvl91