Amends 204 & 186 to Licenses DPR-70 & DPR-75,respectively. Amends Revise Containment Hydrogen Analyzer Surveillance Requirements of TS 4.6.4.1 to Increase Calibr Frequency to Quarterly
ML20203A543
Person / Time
Site: Salem  
Issue date: 01/29/1998
From: Stolz J
Office of Nuclear Reactor Regulation
To:
Public Service Electric & Gas Co, Philadelphia Electric Co, Delmarva Power & Light Co, Atlantic City Electric Co
Shared Package
ML20203A549 List:
References
DPR-70-A-204, DPR-75-A-186 NUDOCS 9802240056
Download: ML20203A543 (8)


Text

-.

  1. cio

[

t UNITED STATES g

s

}

NUCLEAR REGULATORY COMMISSION f

WASHINGTON, O.C **Mt

%,..... /

EUBLIC SERVICE ELECTk4 & GAS COMPANY PHILADELPHIA ELECTRIC COMPANY DELMARVA POWER AND LIGHT COMPANY ATLANTIC CITY ELECTRIC COMPANY DOCKET NO. 50 272 SALEM NUCLEAR GENERATING STATION. UNIT NO.1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 204 Ucense No. DPR 70 1.

The Nuclear Regulatory Commission (the Commission or the NRC) has found that:

A.

The application for amendment filed by the Public Service Electric & Gas Company, Philadelphia Electric Company, Dc!marva Power and Light Company and Atlantic City Electric Company (the licensees) dated October 24,1997, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance: (l) that the activities authorized by this amendment can be conducted without endangering the heelth and safety of the pubile, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's raculations and all applicable requirements have been satisfied.

2.

Accordingly, the licenso is amer.ded by changes to the Technical Speelfications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR 70 is hereby amended to read as follows:

9002240056 900129 PDR ADOCK 05000272 P

PDR

d 2

(2) 7echnical Soecifications and Environmental Protection Plan The Technical Specifications contained in Appendices A and B, as revised through Amendment No204, are hereby incorporated in the license. The licensee shall opc. ate the facility in accordance with the Technical Specirmations.

3. This license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION db

Stolz, Director 3roj ct Directorate 12

' ' lon of Reactor Projecte.1/11 Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of lasuance: January 29, 1998

.-n-

- - +

-,n.

,---r-

---,e-

l.

ATTACHMENT TO LICENSE AMENDMENT NQ 204 FACILITY OPERATING LICENSE No. DPR 70 DOCKET NO. 50122 Revise Appendix A as follows:

Remove Pane insert Paq 3/4618 3/4618

=

3

CONTAINMENT SYSTEMS 3/4.6.4 COMBUSTIBLE GAS CONTROL HYDROGEN ANALY1ERS LIMITING CONDITION FOR OPERATION 3.6.4.1 Two independent containment-hydrogen analyzers shall be OPERABLE.

APPLICABILITY: MODES 1 and 2.

ACTION:

With one hydrogen analyzer inoperable, restore the ino),erable analyzer to CPERABLE status within 30 days or be in at least HOT STANDBY within the next l

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

With both hydrogen analyzers inoperable, restore at least one analyzer to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

SURJIILLA!K.E REQUIREMENTS 4.6.4.1 Each hydrogen analyzer shall be demonstrated OPERABLE by the performance of a CHANNEL CHECK at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, a CHANNEL FUNCTIONAL TEST at least once per 92 days, and at least once per 92 days by l

performing a CHANNEL CALIBRAT1'ON using sample gases containingt Two volume percent hydrogen (low span), balance Nitrogen, and a.

b.

Six volume percent hydrogen (high span), balance Nitrogen.

SALEM - UNIT 1 3/4 6-18 Amendment No.

J)),204

en Caog y

-t UNITED STATES

  1. }

NUCLEAR REGULATORY COMMISSION s

4 WAsHINo7oN, D.C. 3066H001

.....l 4

PUBLIC SERVICE ELECTRIC & GAS COMPANY PHILADELPHIA ELECTRIC COMPANY DELMARVA POWER AND LIGHT COMPANY ATLANTIC CITY ELECTRIC COMPANY DOCKET NO. 50-311 SALEM NUCLEAR GENERATING STATION. UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.186 License No. DPR 75 1.

The Nuclear Regulatory Commission (the Commission or the NRC) has found that:

A.

The application for amendment filed by the Public Service Electric & Gas Company, Philadctphia Electric Company, Delmarva Power and Light Company and Atlantic City Electric Company (the licensees) dated October 24,1997, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and ths fuies and regulations of the Commission; C.

There is reasonable assurance: (i) that the activ'Ds authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter I; D.

The issuance of this amendment will not be inimical to the coinmon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR 75 is hereby amended to read as follows:

l 2-(2) Technical Boecifications and Environmental Protecc M Plan The Technical S >ecifications contained in Appendices A and B, as revised through Amendment No;.86, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifmations.

3. This license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

~~

r Jo nr. Stolz, Diremr Pr ect Directorate 12 ision of Reactor Projects - t/Il Office of Nuclece Reactor Regulation

Attachment:

Changes to the Technical Specif: cations Date of issuance: January 29, 1998

_,.7 9

..-.y

ATTACHMENT TO LICENSE AMENDMENT NO. int, FACILITY OPERATING LICENSE NO. DPR 75 l

DOCKET No. 50 311 Revise Appendix A as follows:

Remove Pane insert Pane 3/4621 3/4621 r

s

CONTAINMENT SYSTEMS 3/4.6.4 COMBUSTIBLE GAS CONTROL HYDROGEN ANALYZERS LIMITING CONDITION FOR OPERATION 3.6.4.1 Two indepencent containment hydrogen analyzers shall be OPERABLE.

APPLICABILITY: MODES 1 and 2.

ACTION:

With one hydrogen analyzer inoperable, restore the inoperable analyzer to OPERABLE status within 30 days or be in at least HOT STANDBY within the next C hours.

With both hydrogen analyzeza inoperable, restore at least one analyzer to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

-SURVEILLANCE REQUIREMENTS a

4.6.4.1 Each hydrogen cualyzer shall be demonstrated OPERABLE by the performance of a CHANNEL CHECK at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, a

'CHANKEL FUNCTIONAL TEST at least once per 92 days, and at least once per 92 days by performing a CHANNEL CALIBRATION using sample l gas containing:

Two volume percent hydrogen (low span), balance Nitrogen, a.

and b.

Six volume percent hydrogen (high span), balance Nitrogen.

SALD.

UNIT 2 3/4 6-21 Arnendment No. J M,186

'