ML20203A392

From kanterella
Jump to navigation Jump to search
Forwards Testing Data & Associated Results for Fitness for Duty Program at Vermont Yankee for Period 980701-981231
ML20203A392
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 02/03/1999
From: Balduzzi M
VERMONT YANKEE NUCLEAR POWER CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
BVY-99-18, NUDOCS 9902090351
Download: ML20203A392 (3)


Text

,

r --

.. VERMONT YANKEE NUCLEAR POWER CORPORATION ry P.O. Box 157, Governor Hunt Road

{

Vernon, Vermont 05354-0157 (802) 257-7711 February 3,1999 BVY 99-18 U.S. Regulatory Commission Washington, D.C. 20555 ATTN: Document Control Desk

Reference:

a) License No. DPR-28 (Docket No. 50-271)

Dear Sir:

Subject:

Fitness for Duty Program for the Period 7/1/98 - 12/31/98 Pursuant to the provisions of 10 CFR 26.71, enclosed is the testing data and associated results for the Fitness for Duty Program at Vermont Yankee. The attached information includes both our corporate and plant locations as our program does not distinguish between the two sites but treats them as a single entity.

Also, provided as Attachment A, is the evaluation of the data for the period.

We trust that the enclosed information is adequate; however, should you have any questions, please feel free to contact us.

Very truly yours, Vermont Yankee Nuclear Power Corporation

$l l1 I

Michael A. Balduzzi j

Plant Manager v\\

l So E'

O

9902090351 990203 O

PDR ADOCK 05000271 R

PDR L1

~

i

l l

~

FITNESS FOR DUTY PROGRAM SEMI-ANNUAL PERFORMANCE DATA REPORT-PERSONNEL SUBJECT TO 10CFR26 l

SECTION l-Company Data Company: Vermont Yankee Nuclear Power i

7/1/98 - 12/31/98 Location:

Govemor Hunt Road 6 month period P.O. Box 157 Vemon,VT 05354 Drugs tested for Screen / Confirmation (ng/mt)

Point of

Contact:

John M. Moriarty, Security Manager Marijuana 100/15 Manjuana 50/15 Phone #:

(802)258-5801 Cocaine 300/150 Opiates 300/300 Amphetamines 1000/500 Phencyclidine 25/25 Alcohol (% BAC) 0.04% BAC Random testing rate: NLT 50% per annum.

SECTION ll-Testing Results Long-Term Short-Term Licensee Employees Contractor Personnel Contractor Personnel Average Number with Unescorted

^ # 88 417 340 86 Categories

  1. Tested
  1. Positive
  1. Tested
  1. Positive
  1. Tested
  1. Positive Pre-Access 22 75 33 For-Post Accident Cause Observed Random 138 74 48 j

Follow-up 1

i Other (Retum to Duty) 3 80 9

i Totals 164 229 90 i

SECTION lli-Breakdown of Confirmed Positive Tests for Specific Jui; stances j

l Marijuana l

Amphe.

Phency-Refusal tamines 100/15 50/15 Cocaine Opiates clidine Alcohol To Test 1

2 3

4 5

l Licensee Employees Long-Term Contractors Short-Term Contractors Total Totals 4

1 l

i Attachment A Evaluation of FFD Data 7/1/98 - 12/31/98 For-Cause Test Results No for-cause tests were required to be administered during this evaluation l

period.

l Positive Test Results j

There were no (0) positive test results during this period.

Follow-up Testina Proaram i

As a result of a confirmed positive on 11/10/97 that was reported during the appropriate period, one (1) individual remains in a follow-up testing program that was initiated as a management referral. His progress to date has been satisfactory.

Test Results Assessment The test results for this period compared to previous periods indicate that Vermont Yankee continues to maintain an effective FFD program which ensures that the plant site remains a work environment free from j

the effects of drugs and alcohol. The number of positive test results experienced during this period are as expected during a period that does not include a refueling outage.

l l

l l

,