Forwards Ofc of Investigations Rept 4-84-050 Re Efforts to Determine Whether Util QC Supervisor Intimidated QA Auditors,Per Request.W/O Encl
ML20202H950
Person / Time
Site: Comanche Peak  Luminant icon.png
Issue date: 11/05/1985
From: Martin R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Gagliardo J
NRC - COMANCHE PEAK PROJECT (TECHNICAL REVIEW TEAM)
Shared Package
ML20202H944 List:
References
FOIA-86-378 NUDOCS 8607160469
Download: ML20202H950 (2)


Text

-

NOV 5 118 5 MEMORANDUM FOR: James E. Gagliardo, Chairman Comanche Peak Intimidation Panel FROM: Robert D. Martin, Regional Administrator Region IV

SUBJECT:

01 FINDINGS CONCERNING ALLEGED INTIMIDATION OF TUGC0 QA AUDITORS BY TUGC0 QC MANAGEMENT We have received the attached investigation (case file number 4-84-050) from the Office of Investigations (01). The report describes 01's efforts to determine whether a Texas Utilities Generating Company (TUGCO) Quality Control (QC) supervisor at the Comanche Peak Steam Electric Station (CPSES) intimidated quality assurance (QA) auditors. We understand that the Intimidation and Harassment Panel has been requested by Mr. V. Noonan to review this case.

Consequently, at your request, we are hereby forwarding you a copy of the OI report.

ORIGINAL SIGNED BY ROBERT D. MARTIN Robert D. Martin Regional Administrator .

Enclosure:

As stated cc w/o enclosure:

J. Axelrad RIV:E0 DAPowers/vig RA RDMartin A(

///g /85 il/( /85 g 71 g 9 860711 GARDE 86-378 PDR

w~, '/

s

~ /*%, UNITED STATES

  • .. NUCLEAR REGULATORY COMMISSION kwD)$ MEGloN IV 611 RYAN PLAZA DRIVE, SulTE 1000 ARLINGTON. TEXAS 76011 NOV 5 r!05 MEMORANDUM FOR: James E. Gagliardo, Chairman Comanche Peak Intimidation Panel FROM: Robert D. Martin, Regional Administrator Region IV

SUBJECT:

01 FINDINGS CONCERNING ALLEGED INTIMIDATION OF TUGC0 QA AUDITORS BY TUGC0 QC MANAGEMENT We have received the attached investigation (case file number 4-84-050) from the Office of Investigations (01). The report describes 01's efforts to determine whether a Texas Utilities Generating Company (TUGCO) Quality Control (QC) supervisor at the Comanche Peak Steam Electric Station (CPSES) intimidated quality assurance (QA) auditors. We understand that the Intimidation and Harassment Panel has been requested by fir. V. Noonan to review this case.

Consequently, at your request, we are hereby forprarding you a copy of the 01 report. /

hif obert D. Martin Regional Administrator

Enclosure:

As stated cc w/o enclosure:

J. Axelrad j O A9  ;