ML20202G263

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 70-7001/97-14 on 971125-980120 & Nov. Violations Are of Concern,Due to Indication of Continued Problems That Exist W/Understanding & Rigorous Implementation of Requirements for Safety Program at Site
ML20202G263
Person / Time
Site: Paducah Gaseous Diffusion Plant
Issue date: 02/12/1998
From: Hiland P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: John Miller
UNITED STATES ENRICHMENT CORP. (USEC)
Shared Package
ML20202G267 List:
References
70-7001-97-14, NUDOCS 9802200097
Download: ML20202G263 (2)


Text

.

y,

?

i February'12,!1998 j

Mr. J - H. Millar i iVice President Production  !

-: United States Enrichment Corporation -- 1

~ Two Democracy Center-

- 6903 Rockledge Drive

  • Bethesda, MD 20817= 1

SUBJECT:

NRC INSPECTION REPORT 70 7001/97014(DNMS) -

AND NOTICE OF VIOLATION - ,

De'ar Mr, Miller:- ,

- On January 20,1997, the NRC completed a routine resident inspection at your Paducah  :

Gaseous Diffusion Plant. The enclosed report presents the results of the inspection, During the J period covered by the inspection report, the conduct of activities at the Paducah Gaseous Diffusion Plant were generally adequate.

L Based upon the results of the inspection, the NRC has determined that violations of NRC L - requirements occurred. The violations are cited in the enclosed Notice of Violation (Notice) and-.

the circumstances surrounding them are desenbod in detail in the onclosed report. -The i '

f.- violations are of concem because they indicate continued problems exist with the understanding

< and rigorous implementation of the requirements for the nuclear criticality safety program at the E site.-

You a,i required to respond to this' letter and should follow the instructions specified in the

. enclosed Notice when preparing your response, The NRC will use your response, in part, to -

4 determine whether further enforcement action is necessary to ensure compliance with regulatory L- . requirements.

in accordance with 10 CFR 2.790 of the NRC's " Rules of Practice" a copy of this letter, its enclosures, and your response will be placed in the NRC Public Document Room.

l I

\-

i \

. 200010 i n

~

9902200097 990212 tang r

PDR

_C.

ADOCK 07007001 PDR 33' {h,kkkk

,_ .. __ .i. l . . ,_ ... . _ - . . . , _

Q l

J. Miller' ^ - We will gladly discuss any questions you have concoming these observations.

Sincerely,-

! Original Signed by Patrick L. Hiland, Chief Fuel Cycle Branch Docket No. 70 7001-

Enclosures:

1 Notice of Violation.

2. Inspection Report 70 7001/g7014(DNMS) cc w/encls: _ S. A. Polston, Paducah General Manager.

L. L. Jackson, Paducah Regulatory Affairs Manager J. Morgan, Portsmouth Acting General Manager S. A.Toolle, Manager, Nuclear Regulatory -

Assurance and Policy, USEC Paducah Resident inspector Office Portsmouth Resident inspector Office

J. C. Hodges, Paducah Site Manager, DOE Distribution R. Pierson, NMSS w/encls = E, McAlpine, Ril w/encls -

PUBLIC (IE 07) w/encls

= OCFO/LFARB w/encls P. Ting,- NMSS w/encls _ F. Wenslawski, RIV/WCFO w/encls 2 A; B. Beach, Rill w/encls W. Schwink, NMSS w/encls Rlli Enf. Coordinator w/encls -

_ J. L. Caldwell, Rill w/encls - P. Harich,' NMSS w/encls . - LEO w/encls -

C; D. Pederson, Rlli w/encls : M. L. Hom, NMSS w/encls DOCDESK w/encls

=

R. J. Caniano, Rlll w/encls t R. Bellamy,' RI w/encls -

u -

i ik ,

e.

J J

t

-m

'.- DOCUMENT NAME: G:\SEC\ PAD 97014.DNM T-1^ ' To receive a copy of this document. Indicate in the boa:"C" = Copy without enclosure "E"a Copy with enclosure"N"a No copy OFFICE - Rlli lF l l l .

I -

NAME Hiland:ib f=l /d DATE 020198 OFFICIAL RECORD COPY

- - - - -. _. . - . . . - - ..- . . - . -