MCEl-0400-47 Page 1 of 21 Revision 14 McGuire 2 Cycle 12 Cere Operating Limits R: port g

McGuire Unit 2 Cycle 12 Core Operating Limits Report November 1997 (Rev.1)

Duke Power Company Date Prepared By:

T

',A /t 73nt

.?yu,v,+

(.

  • /Mv0 Checked By:

aus i

w

,r-Checked By:

[) A/_ /M

///Ay/i?

v-o Approved By: /[

[Ad

// VM?

QA Condition 1 NOTE The contents of this docurr.ent have been reviewed to verify that no mr.terial herein either directly or indirectly changes or affects the results and conclusions presented in the 10CFR50.59 M2C12 Reload Safety Evaluation (calculation file: MCC-1552.08-00-0279).

9712090129 971203

)

PDR ADOCK 0500L370 P

PDR i

MCEl-0400-47 Page 2 of 21 Revision 14 McGuire 2 Cycle 12 Cere Operating Limits Report IMPLEMENTATION INSTRUCTIONS FOR REVISION 14 Revision 14 to the McGuire Unit 2 COLR is being performed to update the Refueling Water Storage Tank minimum contained borated water volumes associated with Technical Specifications 3.1.2.5 and 3.1.2.6. The change in vorated water volumes is being performed in response to the Technical Specification amendment request (dated October 13,1997) which is changing the ESF trip setpoint for FW automatic switchover to recirculation. This COLR update shall not be implemented prior to the Technical Specification Amendment is approved, and it is confirmed that the RWST additional margin of 23,500 gallons proposed in the Technical Specification amendment for calculating tank volume requirements to maintain SDM in modes 1-4 and 5-6 is unchanged. This revision also correc.s a nnsspelling of the word " unacceptable" in Figure 1.

e

MCEl 0400 47 Page 3 of 21 Revision 14 McGuire 2 Cycle 12 Cere Operating Limits R: port REVISION LOG Revision Effective Date Effective Panes COLR Revisions 0-2 Superseded.

N/A M2C09 Revisions 3-6 Superseded N/A M2C10 Revisions 7-12 Superseded N/A M2C11 Revision 13 October 23,1997 5-8 and 12-21 M2Cl2 Revision 14 November 24,1997 1-4,9,10 and 11 M2C12 - rev.1 F

e 6

4 I

l

[

~"

MCEI 0400-47 l

Page 4 of 21 Revisiot. !4 McGuire 2 Cycl 312 Orre Operating Limits Report INSERTION SHEET FOR REVISION 14 R(move Rev.13 pages Insert Rev.14 pages Pages 1-4 and 9-11 Pages 1-4 and 9-11 i

_. ]

MCEl-N00-47 Page 9 of 21 Revision 14 McGuire 2 Cycle 12 Core Operating Limits Report 1

15 0.9 --

Unaccaptable Operation J

.t 0.8 --

~

bg 0.7 i)<0.5--

0.6 -

g4 yy0.4-~

Acceptable Operation

~

O B

0.3 --

lii" 0.2 --

.g A

om 0.1 --

0 0

10 20 30 40 50 60 70 80 90 100 Percent of Rated Thermal Power Figure 1 Moderator Temperature Coefficient Versus Power Level NOTE: Compliance with Technical Specification 3.1.1.3 may require rod withdrawal limits.

Ref:r to OP/2/A/6100/22 Unit 2 Data Book for details.

MCEl 0400-47 Page 10 0f 21 Revision 14 McGuire 2 Cycle 12 Ccre Operating Limits Report 3.1 Tech Spec 3/4.1.2.5 Borated Water Source Shutdown 3.1.1 Volume and boron concentrations for the Boric Acid Storage System c.nd the Refueling Water Storage Tank (RWST) during modes 5 & 6:

Parameter LiDN1 Boric Acid Storage System minimum contained 8,884 gallons borated water volume for LCO 3.1.2.5a 10.0% level Boric Acid Storage System minimum boron 7,000 ppm

=

concentration for LCO 3.1.2.5a Boric Ac;d Storage System minimum water 585 gallons volume required to maintain SDM at 7,000 ppm a

Refueling Water Storage Tank minimum contained 43,000 gallons borated water volume for LCO 3.1.2 Sb 35.0 inches Refueling Water Storage Tank minimum boron 2,675 ppm concentration for LCO 3.1.2.5b Refueling Water Storage Tank minimum water 3,500 gallons volume required to maintain SDM at 2,675 ppm l

A

MCEl-040047 Page 11 of 21 Revision 14 McGuire 2 Cycle 12 Ccre Operating Limits R: port 3.2-Tech Spec 3/4.1.2.6 - Borated Water Source - Operating 3.2.1 Volume and boron concentrations for the Boric Acid Storage System and the Recueling Wt Storage Tank (RWST) during modes 1,2,3, & 4:

Parameter Lima Boric Acid Storage System minimum contained 22,520 gallons borated water volume for LCO 2.i.2.6a 39,0% level i

Boric Acid Storage System minimum boron 7,000 ppm concentration for LCO 3.1.2.6a Boric Acid Storage System minimum water 11,851 gallons volume required to maintain SDM at 7,000 ppm Refueling Water Storage Tank ininimum contained 96,607 gallons boratert water volume for LCO 3.1.2.6b 103.6 inches t

Refueling Water Storage Tank minimum boron 2,675 ppm concentration for LCO 3.1,2.6b Refueling Water Storage Tank maximum boron 2,875 ppm concentration for LCO 3.5.5b Refue'ing Water Storage Tank minimum water 57,107 pjillons volume required to maintain SDM at 2,675 ppm 3.3 Tech Spec 3/4.1.3.5 - Shutdown Rod Insertion Limit 3.3.1 The shutdown rods shall be withdrawn to at least 226 steps.

3.4 Tech Spec 3/4.1.3.6 - Contiel Rod insertion Limits 3.4.1 The control rod banks shall be limited to physical insertion as shown in Figure 2.

3.5 Tech Spec 3/4.2.1 - Axial Flux D8fference 3.5.1 The Axial Flux Difference (AFD) Limits are provided in Figure 3.

i