ML20202F575

From kanterella
Jump to navigation Jump to search
Clarifies Info Provided in Re Request for Partial Exemption from ASME Section XI Requirements for Snubber Insps.Boundaries of Snubbers That Will Be Visually Inspected Described
ML20202F575
Person / Time
Site: Wolf Creek 
Issue date: 07/10/1986
From: Koester G
KANSAS GAS & ELECTRIC CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
KMLNRC-86-125, NUDOCS 8607150195
Download: ML20202F575 (1)


Text

n KANSAS GAS AND ELECTRIC COMPANY THE ELECTRAC COMPANY July 10, 1986 GLENN L MOESTER wect Pats.oth? muctsam Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555 KMLNRC 86-125 Re:

Docket No. STN 50-482 Ref:

KMLNRC 86-011, dated 1/20/86 f rom GLKoester, KG&E, to HRDe nt on, NRC Subj:

Additional Inf ormation Concerning Snubber Visual Inspe c t ions

Dear Mr. Denton:

The purpose of this le t te r is to provide clarification of inf ormation provided in reference I concerning a request f or a partial exemption to ASME Se c t ion XI re quire ment s for snu bbe r ins pe c t ion s.

In a discussion with membe rs of your staf f, additional information was re que s te d to clearly ide nt if y the bounda rie s of snubbers which will be visually inspected in accordance with the Wolf Creek Generating Station (WCGS),

Unit No.

1, Technical Specifications.

The boundaries of the Technical Specification visual inspection of snubbers at WCGS include t he snu bbe r structural attachment to the foundation or supporting structure, up to and including the fasteners for connecting the snubbers to the pipe attachment or component attachment.

Fasteners are pins or bolts which connect the snubber to a pipe or component attachcont.

The pipe or component a t ta chme nt is not cons ide re d part of the Technical Spe cif ica t ion snubbe r visual inspection however it is included in the WCGS ASME Section XI inservice inspection program.

Also, any component support s tee l,

including ASME Section III NF steel, connected to the snubbe r structural attachment will be visually inspected under WCGS ASME Section XI re qui re me nt s.

If any part of the boundary included in the Technical Specification inspection cannot be ve rif ie d to be f unct iona l due to insulation inte rfe re nce then the insulation will be removed to satisf y the inspection requirements contained in the Technical Specifications,.

If you have any questions concerning this matter please contact un or Mr. O.

L. Maynard of my staff.

Yours very truly, hh82 8

71 G e nn L. Koe s te r Pg PDR Vice Pre side nt - Nuclear GLK:see cc: P0'Connor (2) od JCummins 201 N. Market - Wichita, Kansas - Mail Address: PO. Box 208 I Wichita, Kansas 67201 - Telephone: Area Code (316) 261-6451 h