Forwards Insp Rept 50-213/97-05 on 970708-1006.No Violations Noted.Other Concerns in Area of Procedure Quality,Personnel Errors,Poor Matl Conditions & Tracking of Commitments
ML20202F085
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 11/26/1997
From: Conte R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Feigenbaum T, Mellor R
CONNECTICUT YANKEE ATOMIC POWER CO.
Shared Package
ML20202F089 List:
References
50-213-97-05, 50-213-97-5, EA-97-079, EA-97-79, NUDOCS 9712090005
Download: ML20202F085 (3)


See also: IR 05000213/1997005

Text

--

_-

-.

o

(M

Nonnber 26, 1997

EA 97-079

Mr._Ted C. Felgenbaum

.

Executive Vice President and Chief Nuclear Officer

c/o Mr. R. A. Mellor, Director

Site Operations and Decornmissioning

Connecticut Yankee Atomic Power Company

362 Injun Hollow Road

East Hampton, CT 06424 3099

SUBJECT:

NRC INTEGRATED INSPECTION REPORT 50 213/97-05

Dear Mr. Feigenbaum:

On October 6,1997, the NRC completed an inspection at Connecticut Yankee Atomic

Power Company. The enclosed report presents the results of that inspection.

During the three month period covered by this inspection period, the Haddam Neck staff

contir.ued to assure the safe storage of spent fuel, and addressed severalissues important

to shutdown oporations and to d'> commissioning. A good regard for plant spent fuel safety

was noted in your efforts to addressBulletin 94-01 issues and the consequences of

beyond design basis events, a totalloss of pool water. Several events challenged

operators, including an inadvertent actuation of the halon system that caused operators to

leave the control room for about forty-five minutes. Our inspection noted other concerns in

the areas of procedure quality, personnel errors, poor material conditions, and the tracking

of commitments. We encourage your efforts to improve performance in these areas.

Progress was noted in the comp!stion of actions to pkn for decommissioning. The

radiological controls for routine work ,sas acceptable, and the actions to address

weaknesses in the program to calibrate the radiation monitoring system were well

conceived and executed.

In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this ictter

and its enclosures will be placed in the NRC Public Document Room (PDR).

Sincerely,

Original Signed By:

Richard J. Conte, Chief

'

g ,) p ,: ^O

Reactor Projects Branch #8

1

,/ g {

sv

-

Division of Reactor Projects

.

s

Docket No. 50 213

/

License No. DPR-61 -

$l

,

9712090005 971126

PDR

ADOCK 05000213

G

PM

,

--

_

- -

.

. -.

-

-

- .

. - . - - -

-

_.

.

n

Mr. Ted C. Folgenbaum--

2

'

Enclosure:

NRC Inspection Report No. 50 213/97-05

cc w/ encl:

B. Kenyon, President and Chief Executive Officer

D. Goebel Vice President - Nucleai Oversight

F. Rothen, Vice President - Nuclear Work Services

D.- Amerine, Vice President, Nuclear Engineering and Support

L. Cuoco, Senior Nuclear Counsel

. G. van Noordennen, Manager, Nuclear Licensing

R. Juhannes, Director Nuclear Training

J. Smith, Manager, Operator Training

W. Meinert, Nuclear Engineer

. R. Bassilakis, Citizens Awareness Network

J. Block, Attorney for CAN

J. Brooks, CT Attorney General Office

M. DeBold, Town of Haddam

State of Connecticut SLO

.

f-

,

--

-n--

7

-

_

'

g

Mr. Ted C.' Feip% cam -

3

,

Distribution w/ encl:

Region l Docket Room (with concurrences)

PUBLIC

~ Nuclear Safety Information Center (NSIC)

NRC Resident inspector

H. Miller, RA\\W. Axelson, DRA

D. Screnci, PAO

R. Conte, DRP

M. Conner, DRP

C. O'Daniell, DRP

J. White, DRS

i

Distribution w/enci (VIA E MAIL):

K. Kennedy, OEDO

.S. Weiss, NRR, DRPM, PDND

M. Fairtile, PM, NRR

M. Callahan, OCA

W. Travers, SPO

R. Correia, NRR

F. Talbot, NRR

R. Zimmerman, ADPR, NRR

J. Goldberg, OGC (LFD, AEN)

J. L.leberman, OE (OEMAIL)

D. Holody, EO, RI

DOCDESK

Inspection Program Branch, NRR (IPAS)

DOCUMENT NAME: g:\\ branch 8\\1-hn\\97-05.rpt

. To ,ecetwo a topy of this document. hecote in the box:

'C' = Copy without attachment / enclosure

"E* = Copy with attachment / enclosure

  • N* = No copy

' OFFICE

Rl/DRP

a/

Rl/DRP

l

NAME

CONTE

f)U

WHITE (Luf

yE

.11p(797/" '/

1 4d97

//97

-/ /97

'

OFFICIAL RECORD COPY

L-