DUKE POWER GOMPAAT P.O. HOK T)180 CHAMLOTTE, N.C. 28242 IIAL D. TL'CKER TELEPHONE voce ramstomwr (704) OTNS31 wtuaan reons.cv*ow July 7, 1986 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Attention:

Mr. B. J. Youngblood, Project Director PWR Project Directorate No. 4 Re:

Catawba Nuclear Station McGuire Nuclear Station Docket Nos. 50-413 and 50-414 Docket Nos. 50-3269 and 50-370

Dear Sir:

l Mr. B. J. Youngblood's letter of May 2,1986 transmitted a copy of NUREG/CR-3954, "HECTR Analysis of Equipment Temperature Responses to Selected Hydrogen Burns in an Ice Condenser Containment". This letter requested that Duke provide comments regarding the relevance of the subject document to McGuire and Catawba.

Comments on a June, 1984 draft of NUREG/CR-3954 were previously provided, beginning on page 7.0-144, in Revision 12 to Duke Power Company's report, "An Analysis of Hydrogen Control Measures at McGuire Nuclear Station" which was transmitted by my J

letter of March 29, 1985.

We have no other comments at this time.

Very truly yours,

/h e

c Hal B. Tucker i

ROS: sib xc:

Dr. J. Nelson Grace, Regional Administrator U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr. W. T. Orders t

NRC Resident Inspector I

McGuire Nuclear Station NRC Resident Inspector Catawba Nuclear Station I

8607150035 860707 PDR ADOCK 05000369 u0 5

P PDR h