_ _ _ _ _ _ _ - - _ _ - _ _ _ _ _ _ _ _ _ _ _
i South Carolina Electric & Gas Company Dan A.Nauman a
P.O. Box 764 Wee President ia mb 29218 Nuclear Operations SCE&G 0 3 '*
peil 1, 1986
, v.
3 I
Dr. J. Nelson Grace Regional Administrator U.C. Nuclear Regulatory Commission Suite 2900 101 Marietta Street, NW Atlanta, Georgia 30323
SUBJECT:
Virgil C. Summer Nuclear Station Docket No. 50/395 Operating License No. NPF-12 Special Report (SPR 86-003)
Dear Dr. Grace:
Attached is a Special Report for the Virgil C. Summer Nuclear Station.
Tnis report is submitted pursuant to the requirements of Section 6 of the Technical Specifications.
Shoulu there be any questions, please call us at your convenience.
ery tr
- yours,
'D.
la RJB: DAN / led Attachment c:
V. C. Summer K. E. Nodland O. W. Dixon, Jr./T. C. Nichols, Jr.
R. A. Stough E. H. Crews, Jr.
G. O. Percival E. C. Roberts R. L. Prevatte J. G. Connelly, Jr.
J.
B. Knotts, Jr.
W. A. Williams, Jr.
- 3. D.
Hogge Group Managers I&E Washington
.0.
S. Bradham Document Management D. R. Moore Branch C. A. Price INPO Records Center W. T. Frady ANI Library C. L. Ligon (NSRC)
NPCF R. M. Campbell File i
DR en
.~
,l*
Dr. J. Nelson Grace.
SPR 86-003 o
Page Two April 1,1986 EVENT DESCRIPTION On February 20, 1986, the Digital Impact Monitor System began to indicate continuous events on two channels.
ACTION TAKEN i
The system was declared inoperable and a work request initiated for repair.
The cause of the failure was due to a faulty electronic board (signal conditioner).
Repairs and operability testing were satisfactorily completed March 27, 1986.
The system was inoperable for a period of thirty-five (35) days.
This report is being submitted pursuant to the requirements of Action Statement a. of Technical Specification 3 3 3.10, " Loose-Parts Detection System."
l l
l I
1W
_, - - - - - _ _ _ _ _ - - - - - _ _ - - - - _. - - - - -