February 3,1998
'Y0$k,YI!*$"nII/O Mr. Alexander Adams, Jr., Senior Project Manager Non Power Reactor and Decommissioning Project Directorate
- Division of Project Support Office of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Dear Mr. Adams Enclosed is a request to modify the Technical Specifications for Facility Operating License R-108. My original submittal, dated January 29.1998 contained and error.
During reproduction, The first line of page was deleted. Please replace the attached page with the incorrect copy. If you have any questions regarding this review, please contact me at (517) 636-6584, Regards
\\
t h \\
Ward L. Rigot Reactor Supervisor Dow TRIGA Research Reactor The Dow Chemical Company
$ )f.,42Lz, h. bl.
V CONNIE M. MARCH 40TARY Pusuc, MiouNDcouNTY MCHOAN W coMMISSloN EXPIRES DECEMBER 23,2000 h
j tiUb5CRIBED To AND SWORN BEFORE ME
/ d4I/d 419 k THIS AYOF V
.I
,0
^
I 9002120267 900202 l
1 PDR ADOCK 05000264 l
l, p
ppg
_e
. '.,x' 3.6. Radiation Monitorine Systems Aoolicability These specifications apply to the radiation monitoring information available to the reactor operator during operation of the reactor.
Obiective The objective of these specifications is to ensure that the reactor operator has adequate information to assure safe operation of the reactor.
Eoecifications A Continuous Air Monitor (CAM)(with readout meter and audible alarm) a measure radioactive praiculates in the reactor room must be operating du,ing operation of the reactor.
The Area Monitor (AM)(with readout meter and audible alarm)in the reactor -
nom must be operating during operation of the reactor or when work is being done on or around the reactor core or experimental facilities. During short periods of repair to this monitor, not to exceed sixty days, reactor operations or work on or around the core or experimental facilities may continue while a portable gamma-sensitive ion chamber is utillied as a temporary substitute, provided that the substitute can be monitored by the reactor operator, Dases The radiation monitors provide information of existing levels of radiation and air borne radioactive materials which could endanger operating personnel or 3
which could warn of possible malfunctions of the reactor or the experiments in the reactor.
.I
?
Amendment Na 8
-l 7-
+,