.. _ - _ _
l I'
.N._.1.JiE_w w 14LwA_w w w w w w w w w u y w w w w w unvyw w w w w w w y w w w wr-g, NRC FORM 618 U.S. NUCLEAR RE!ULATORY COMMISION g'
I o *e CERTIFICATE OF COMPLIANCE i " C"' "
FOR RADIOACTIVE MATERIALS PACKAGES k
i I e C1.RilHCATE NUMBLR b RLYlSION NUMBER
- c. PACKAGE IDENT1HCATION NUMBER
- d. PAGE NUMBER
- e. TOTAL NUMBLR PAGES pl 9033 12 USA /9033/B(U) 1 3
l g j
h 2 PRLAMhtL N
)
s This cemrgate is issued to certify that the pacLaging and contents degnbed in item $ below, meets the apphcable safety standards set forth in Title 10, N
i
)
4; Code of 1 ederal Regulatons Part 71, " Pac.kaging and Transportation of Radioactive Material.'
!I I
- b. This cemncate does not reheve the consignar from comphance with any erquirement of the regulations of the U.S. Depanrnent of Traasportation or oth-r N
$g apphcable regulatory agencies, including the government of any country through or into which the package will be transpated.
k
$l l
) 1 115 CLRTinCArt is is5Um DN THE B A5IS OF A S AfETY AN ALYS15 RLM)RT OF THE PACKAGE DLSION OR APPLICATION e IS$ULD TO(Naaw sad Adderu)
Bl E
E lp Amersham Corporation Amersham Corporation application dated g
ig 40 North Avenue September 24, 1993, as supplemented.
g i
Burlington, MA 01803 gl g
71-90a3 p
- c. Docker NuMBtR g
4 4 CONDrilONS q
g This certificate is conditional upon fulfilhng the requirements of 10 CFR Part 71, as opphcable and the conditions specified below, g
$=
l (a)
Packaging l
(1)
Model No.:
660, 660E, 6CJA, 660AE, 660B or 660BE U
a l,l (2)
Description l
5 A steel encased uranium shielded Gamma Ray Projector. Primary 8
components consist of an outer steel shell, rolyurethane potting 8
material,. uranium shield, "S" tube, and end plugs. The contents are U
9 securely positioned in the "S" tube by a source cable locking device I
and shipping plug. Tamper-proof seals are provided on the packaging.
8 The maximum total weight of the package is approximately 53 pounds.
E 5
(3)
Drawings 4
B q
The packaging is constructed in accordance-with the following d
8 Technical Operations, Inc. Drawings:
5 B
E i#
(i)
Model'No.s660B - Drawing No. 66025, Sheets 1, 2 and 3, Rev. F; E
i 4
Nj B
(ii) Model No. 660 - Drawing No. '66025, Sheets 1, 2, 3, and 4, Rev, d
i B; or Drawing No. 66030, Sheets 1, 2, 3 and 4, Rev. -;
E Ri 4
(iii) Model No. 660A - Drawing No. 66010, Sheets 1, 2 and 3, Rev. A; 8
or Drawing No. 66030, Sheets 1, 2, and 3, Rev. D.
W E
5 Model Nos. with an E suffix have an electrical circuit, g
4 (b)
Contents W
ej W
D' (1)
Type and form of material E
D E
(%
1ridium-192 sources which meet the requirements of special form radioactive d
materi al.
E W
E 9712010362 971119 I
l C
PDR g
l ca m m m m m m_tagw m m m m m m m m m m m m a m a m m m m m m m m m m m m m m m m m m m m$
gwwwwwwwwwwwwwwwwwwwwwwwwwwww wwww.wwww ww,www.u g NR FORM 61aA CONDm0Ns troanawh U.S. NUCLEAR RE:ULATORY COMMISSH)N l
-Page 2 - Certificate No. 9033 - Revision No. 12 - Docket No. 71-9033 N
N y
5.-
(b)
_ Contents (continued) l (2)
Maximum quantity of material per package l
h (1) 140 Curies for the Model No. 660B or 660BE package.
l (ii) 120 Curies for the Model No. 660, 660E, 660A or 660AE package.
l 8
1 6.
The source shall be secured in the shielded position of the pa.:kaging by the U
- 1 source assembly. The source assombly must be fabricated of materials capable of I
1 resisting a 1475 *F fire environment for one-half hour and maintaining-their I
8 1
positioning function. The source assembly must engage the locking cevice. The U
source assembly must be of sufficient length and diameter to provide positive E
l1 l
positioning of the source.within the depleted uranium shield assembly.
7.
The name plate must be fabricated of materials capible of resisting the fire test I
i
- j of 10 CFR Part 71 and maintaining its legibility.
E
- l 4
8.
In addition to the requirements of Subpart G of 10 CFR Part 71:
N i
N B;
(a)
The package must meet the Acceptance Test and Maintenance Program of I
b Chapter 8.0 of the applict. tion, as supplemented; and W
i E
(b)
The package shall be prepared for shipment in accordance with the Operating d
i Bj Procedures in Chapter 7.0 of the application, as supplemented.
E 1
4 9.
For transportation in private carriage, the package must be either:
E.
D (a) properly secured within a. box attached to the vehicle for the purpose of a
j W
transporting or storing radiography devices. The package must be properly a
j Wj blocked, braced, and supported to prevent shifting within the box during a
transport, or~
q
- l 5
9;
('o) properly secured within a steel drum. The package must be properly q
b; blocked, braced, and supported to prevent shifting within the steel drum W
during transport. The steel drum must be blocked, braced, and secured q
s against movement within the vehicle, g
g Di P
% 10.
For transportation by common carrier, the package must be properly secured within g
B; a steel drum. The package must be properly blocked, braced, and supported to g
B' arevent shifting within the steel drum during transport. The steel drum must be g
p alocked, braceri and secured against movement within the vehicle, g
4 e
11.
Packagings-fabricated after November 17, 1997, are-not authorized for use.
g E
e W
8l N
u N
Bj E
4 i
bi E
B E
i
__-_ b 6.uaunusununus.tammmmmmutamm mmm m mm a a a m_ m m ab _
~
p w w w x w w w_w w w w w w w w w w w w w w p_w_w w w w w w w w w w w w w w w w g NRC FORM SISA CONDmONS tumrmwe U.S. NUCLEAR RE!ULATORY COMMISSION g
b N
I E
DlPage3-CertificateNo.9033-RevisionNo.12
- Docket No. 71-9033 E
N D
W W
D E
P!12.
The package authorized by this certificate is hereby approved for use under 4
general license provisions of 10 CFR 671.12.
W i
W W
- f13.
Expiration date: October 31, 2000.
W Dl REFERENCES E
d ifAmershamCorporationapplicationdatedSeptember 24, 1993.
E.
,l Supplements dated:
p March 31, 1994; June 28, 1995; and November 17 and 18, 1997.
E E
BlNordionInternaticalInc.supplementdatedAugust p
19, 1996.
t a
d FOR THE U.S. NUCLEAR REGULATORY COMMISSION q
D' N
fM u'MN R
.lp Cass R. Chappell, Chief '
q ig Package Certification Section g
lg Spent Fuel Project Office g
gll Office of Nuclear Material Safety g
and. Safeguards g
Date: 11/19/97
.I E
sj a
sj d
9 6
.f N
E a
4
- l E
9 E
s e
s E
i sj d
s, E
5, i
f N
m{;.
N a
W a
Dj E
Bj
- \\
- \\
Bj B
- um.........1.11........1............-
. gag g*
UNITED STATES
,j NUCLEAR REGULATORY COMMISSION WASHINGTON D.C. 2066H001
\\...../
APPROVAL RECORD Model No. 660 Certificate of Contpliance No. 9033 Revision No. 12 In accordance with a Confirmatory Action Letter (CAL 97-7-005), Amersham Corporation re-tested the Model No. 660 transportation package under the hypothetical accident conditions specified in 10 CFR Part 71. During the tests, one of the test units experienced an unexpected failure and did not meet the external radiation standards specified in 10 CFR Part 71.
In letters dated November 17 and 18, 1997, Amersham submitted justification for continued use of existing packagings of this design. Amersham aise proposed compensatory measures to be used for transport of the package.
Certificate of Compliance No. 9033 fer the Model No. 660 series packages is being amended to incorporate the ccmpensatory measures described in the Amersham letter. The amended certificate includes three additional conditions of approval:
1.
For transpetation in private carriage, the package must be either:
(a) properly secured within a box attached to the vehicle for the purpose of transporting or storing radiography devices.
The package ntst be properly blocked, braced, and supperted to prevent sh'.fting within the box during transport, or (b) properly secured within a steel drum. The package must be properly blocked, braced, and supported to prevent shifting within the steel drum during transport. The steel drum must be blocked, braced, and secured against movement w; thin the vehicle.
2.
For transportation by common carrier, the package must be properly secured within a steel drum. The package must be preparly blocked, braced, and supported to prevent shifting within the steel drum during transport. The steel drum must be blocked, braced and secured against inovement within the vehicle.
3.
Packagings fabricated after November 17, 1997, are not authorized for use.
The staff anticipates that the above conditions of approval will be deleted at a future date after Amersham has submitted a revised Safety Analysis Report showing that the package, with any necessary design changes, meets the requirements of 10 CFR part 71.
44 Cass R. Chappell, Chief Package Certification Section Spent Fuel Project Office Office of Nuclear Material Safety and Date 11/19/97