%{ owe "h" CERTIFICATE OF COMPLIANCE lII iOR RADIOACTIVE MATERIAI.S PACKAGES a
a gll i
I.a Cf RTII1CATE NUMBLR b RFVISION NUMBLR c PACKAGE IDENTIDCATION NUMBl.R d PAGE NUMBLR
- e. TOT AL NUMBER PAGES g p
' 9033' 13 USA /9033/B(V) 1 3
l gl I
k g
- 3. PRLAMBLL k
- s. Tius certificate is issued to certify that the packaging and contents demeribed in item s tebw, rnects the apphcable safety standards set forth in Title 10 Code of l ederal Regulations, Pan 11, *Packagirg and Transportation of Ra&oactive Matenal."
Il Nj b This certificate does not reheve the consignor from comphance with any requirement of the regulations of the U.s. Depanment of Transpanation or ceher k
apphcable regulatcry agencies,inclueng the government of any country throogh w into which the package will te transported.
N
$g N
I ;. THi5 Cl RTHICATL 15 ls5UI D ON THE B A$l$ OF A $ All:TY AN ALY$t$ RI~ PORT OF THE PACKACF, DESIGN OR APPLICATION j
e 155CI.D TO (Mw.e sad AJJen) b T1TLE AND IDENT1HCATION OF REPORT OF APPLICATION:
k W
le g
g Amersham Corooration Amersham Corporation application dated g
l g
40 North Avenue September 24, 1993, as supplemented, l
y y
Burlington, MA 01803 g
l H-%M g
- c. ooCLi T NUMBcR q
gl 4 cONomoNs a
- his certificate h conditional upon fulfilhng the requirements of 10 CI n Part 71, as applicable, and the condaions specified below.
(
%5 5
g Packaging g
fl(a)
(1)
Model No.: 660,660E,660A,660AE,660Bori60BE l
(2)
Description l
A weel encased uranium shielded Gamma Ray Projector. Primary 8
'l components consist of an outer steel shell, polyurethane potting 8
8; material, uranium shield, "S" tube, and end plugs. The contents are N
securely positioned in the "S" tube by a source cable locking device U
%j and shipping plug. Tamper-proof seals are provided on the packaging.
E The maximum total weight of the package is approximately 53 pounds.
8 4
(3)
Drawings a
N
- l The packaging is constructed in accordance-with the following a
Technical Operations, Inc. Drawin.ns:
N 4
(i)
Model No. 660B - Drawing No. 66025, Sheets 1, 2 and 3, kev. F; E
Bj W
(ii) Model No. 660 - Drawing No. 66025, Sheets 1, 2, 3, and 4. Rev.
E B; or Drawing No. 66030, Sheets 1, 2, 3 and 4, Rev. -;
E N
(iii) Model No. 660A - Drawing No. 66030, Sheets 1, 2 and 3, Rev. A; e
or Drawing No. 66030, Sheets 1, 2, and 3, Rev. D.
E s
E D
Model Nos. with an E suffix have an electrical circuit.
p E
R Contents a
(b) 4 (1)
Type and form of material d
4 f ridium-192 sotm.es which meet the requirements of special forri, radioactive E
material.
W N
N l
9712010352 971121 E
l l
C PDR g
!smrrienn e m a m m m m m m m m m m m m m m m m m m m m m m m m m rt a rm m m m< m m m m m$
l
,w x w_w_y_w_w.m m.m s w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w w wg e-g gcronustsA cowmossm-
.o u.s. NUCLEAR cE!ULATORY COMMISSION g
I N
Page 2 - Certificate No. 9'033 - Revision No. Docket No. 71-9033 g
g D'
W I
D I
y 5.
(b)
Contents (continued) g D
E ip (2)
Maximum quantity of material per package g
(1) 140 Curies for thi Model No. 660B or 660BE package.
l (ii) 120 Curies for the Model No. 660, 660E, 660A or 660AE package.
l
$6 l
h The source shall te secured in the shielded position of the packaging by the source assembly. The source assembly must be fabricated of materials ca)able of g
i resisting a 1475 'F fire environment for one-half hour and maintaining t1eir l
'l positioning function. The source assembly must engage the locking device. The 5
source assembly must be of sufficient;1ength and diameter to provide positive
- positioning of the source _within the depleted uranium shield assembly.
l fl 7.-
D The name plate must be ' fabricated of materials capable:of resisting the fire test a
of 10 CFR Part 71 and maintaining its legibility.
l 8.
In addition to the requirements of Subpart G of 10 CFR Part 71:
l (a)
The package must meet the Acceptance Test and Maintenance Program of 8
Chapter 8.0 of the @p11 cation, u supplemented; and I
8 (b)
The package shall tre. prepared for shipeent in accordance with the Operating I
Procedures in Chapter 7.0 of the application, as supplemented, d
i D
d
%j 9.
For transportation in private carriage, the package must be either:
N Di i
(a) properly secured within a box attached to the vehicle for the purpose of I
transporting or storing radiography devices.
The package must be properly I
blocked, braced, and supported to prevent shifting within the box during I
transport, or W
Dj d
D' (b) properly secured within a steel box of welded construction or a steel drum.
E W
The package must be properly blocked, braced, and supported to prevent d
shifting within the steel box or. steel drum during transport. The steel d
h box or drum must be blocked, braced, and secured against movement within d
q the vehicle.
5 D
d D
- 10..
For transportation by common carrier, the package must be properly secured within d
W a steel box of welded construction or a steel drum. The package must be properly I
p blocked, braced, and supported to prevent shifting within the steel box or steel I
g drum during transport. The steel box or steel drum must be blocked, braced and d
b secured against movement within the vehicle, g
Dli d
b 11.
Packagings fabricated after November 17, 1997, are not authorized for use, d
I I
El N
5 D
u i
D di
%p nl b a m a m m m m m m m u m m m m m m m m m m m m m m m m m mm m m m m m m m m m m
gwwwww_wwwwwwwwwwwwwwwwwwww_w_mususwwwwwwwwwwwwwwww.74 g NRC. FORM 618A CONDm0Ns frommwe U.S. NUCLEAR REGULATORY COMMCSON g
p p
IW di p! Page 3 - Certificate No. 9033 - Revision No.13 - Docket No. 71-9033 q
p'I W
D E
I D
E.
lp a
pl 12.
The package authorized by this certificate is hereby apywved for use under i
general license provisions of 10 CFR 671.12.
y p!
p E
lp 13.
Expiration date: October 31, 2000.
g l
REFERENCES l
Amersham Corporation application dated September 24, 1993.
9 Supplements dated: March 31, 1994; June 28, 1995; and November 17, 18 and 21, 1997.
l l i
19,,1996.
l sl Nordion International Inc. supplement dated August l
l}
FOR THE U.S. NUCLEAR REGULATORY COMMISSION
.i GLA
{h U
4 Cass R. Chappell, Chief.
8}l Package Certification Sectior.
N l
s Spent Fuel Project Office 8 '
is
. office of Nuclear Material Safety N
i#
and SLfeguards 4
1 s
W i
sj Date:
11-21-97 E
i Bl E
,l 4
El E
9 N
4 4
W; W
D E
4 E
D E
R E
n.
q 9,
E W
4 i
4 W;
N b
E D
E N
a
'l 8l e
e of El'.
.i Dj 4!l 1Tn a mm m m m m m m m m m mm m m m m m m m mm m m m m m m m m m m m m m m m m m m m m$
P
~
aneogk UNITED STATES a*
s-g NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. *= "1
%,*...*/
1 APPROVAL RECORD Model No. 660 Certificate of Complian;e No. 9033 Revision No. 13 By application dated November 21, 1997, Amersham Corporation requested an amendment to Certificate of Compliance No. 9033 for the Model 660 series packages.
The request was to modify the compensatory measures to be utilized during transport of the package by private carriage or common carrier to allow the package to be secured within either a steel drum or a steel box of welded construction.
Certificate of Complunce No. 9033 for the Model No. 660 series packages is being amended to incorporate changes to the compensatory measures stated in the November 21, 1997 application. The certificate was amended as follows:
1.
For transportation in private carriage, the package must be either:
(a) properly secured within a box attached to the vehicle for the purpose of transporting or storing radiography devices. The package must be )roperly blocked, braced, and supported to prevent shifting within tie box during transport, or (b) properly secured within a steel box of welded construction or a steel drum.
The package must be aroperly blocked, braced, and supported to prevent shifting wit 11n the steel box or steel drum during transport.
The steel box or drum must be blocked, braced, and secured against movement within the vehicle.
2.
For transportation by common carrier, the package must be properly secured within a steel box of welded construction or a steel drum.
The package must be properly blocked, braced, and supported to prevent shifting within the steel box or steel drum during transport. The steel box or steel drum must be blocked, braced and secured against movement within the vehicle.
Th9 staff anticipates that the above conditions of approval will be deleted at a future date after Amersham has submitted a revised Safety Analysis Report rhowing that the package, with any necessary design changes, meets the requirements of 10 CFR Part 71.
jM A
Cass R. Chappell, Chief
(
Package Certification Section Spent Fuel Project Office Office of Nuclear Material Safety and Safeguards 11-21-97 Date I
i.
l