__---.-.----m RECE7VFD AUS 2 91998 hM[
ym OCT 2 71995 Stan,Smolski gineering Manage %
old Metal Products 5-Burr 4 tt-Street New Britain, Connecticut 06050
Dear Mr Smolski:
This refers to your telephone conversation with Duncan White of this office on October 26, 1995 concerning the transfer of generally licensed fixed gauges from one location to another.
Title 10, Part 31.5(c)(3) of the Code of Federal Regulations {10 CFR 31.5(c)(3)} requires that the installation, servicing, and removal from installation involving radioactive material, its shielding or containment be performed by a person holding a specific license pursuant to 10 CFR 30 and 32 or from an Agreement State to perform such activities. A copy of this regulation is enclosed with this letter.
As a general licensee, you are not authorized to service or remove from installation radioactive material or its shielding and containment. The two LFE gauges that you wish to transfer to another facility can only be removed from service and transferred by a person specifically licensed by the NRC or an Agreement State.
Failure to comply with 10 CFR 31.5(c)(3) is a violation of NRC regulations and could result in the NRC taking enforcement action in accordance with 10 CFR Part 2.
If you have any additional questions regarding this matter, please contact me at (610) 337-5042.
Thank you for your cooperation.
Sincerely, Q60g16 ORIGINAL SIGNED BY:
Francis M. Costello, Chief Nuclear Materials Safety Branch 3 Division of Nuclear Materials Safety Docket No. 99990001
Enclosures:
Parts 2 and 31 9901260104 951027 PDR
-o NME h
-m.w
__[
l
l
.s S. Smolski
Cold Metal Products l
bec:
1 Region I Docket Room (w/ concurrences)
Randy S. Stevens Radiation Safety Officer Integrated Industrial Systems 475 Main Street Yalesville, Connecticut 06492-1723 j
1 DOCUMENT NAME:
R:\\WPS\\MLDL\\COLDMETA To receive a sopy of this document,andicate in the box:
- C* = Lupy w/o attach /enci
- E* = Copy w/ ettach/enct
- N* = No copy 0FFICE DNMS/RI N
DNMS/RIf@ (
N l
l NAME DWhitei5lk FCostello DATE 10/27/93 10/ p /95 10/
/95 10/
/95 NMM
~^
PRFORITYT (NUDOCS OFFSITE FACILITY)
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9512190120 DOC.DATE: 95/10/27 NOTARIZED: NO DOCKET #
FACIL:
AUTH.NAME AUTHOR AFFILIATION COSTELLO,F.M.
Region 1 (Post 820201)
RECIP.NAME RECIPIENT AFFILIATION SMOLSKI,S.
Affiliation Not Assigned p
SUBJECT:
Discusses Cold Metal Products 951026 telcon w/D White re transfer of generally licensed fixed gauges from one R
location to another. Informs that recipient not authorized to service or remove radioactive matl as general license.
l DISTRIBUTION CODE: IE07D COPIES RECEIVED:LTR ENCL SIZE: 2 TITLE: Environ & Radiological (30,40,70 DKT)-Insp Rept.otice of Viol Respon O NOTES:
R RECIPIENT COPIES RECIPIENT COPIES l
ID CODE /NAME LTTR ENCL ID CODE /NAME LTTR ENCL LA 1
L PM 1
1 INTERNAL: AEOD/SPD/RRAB 1
NMSS/FCOB/T8A33 1
L NMSS/IMAB T8F5 1
NMSS/IMOB T8F5 1
L Y
r mMSS/SCDB/SSSSJ l
L NMSS/SFPO'06F18 1
L NUDOCsTXBSTIfKCT 1
L OE DIR 1
L RGNp FILE 01 1
L 2
EXTERNAL: LITCO BRYCE,J H 1
L NRC PDR 1
1 i
D C
i C
O I:l U
W E
N l
T NOTE W ALL
- RIDS" RECIPIENTS:
I PL. EASE IIELP US TO REDUCE WASTE! CONTACT THE DOCUMENTCONTROL DESK, ROOM PI-37 (EXT. 504-2083 ) TO ELIMINATE YOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
O TOTAL NUMBER OF COPIES REQUIRED: LTTR 13 ENCL
)6
.