ML20199H918

From kanterella
Jump to navigation Jump to search
Safety Evaluation Supporting Amend 224 to License DPR-65
ML20199H918
Person / Time
Site: Millstone 
Issue date: 01/20/1999
From:
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20199H916 List:
References
NUDOCS 9901250374
Download: ML20199H918 (3)


Text

. - _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ - _

,pwh p'

1 UNITED STATES j

j NUCLEAR REGULATORY COMMISSION

.g WASHINGTON, D.C. 30666-0001 ge...../

SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO AMENDMENT NO. 224 TO FACILITY OPERATING LICENSE NO. DPR-65 NORTHEAST NUCLEAR ENERGY COMPANY THE CONNECTICUT LIGHT AND POWER COMPANY THE WESTERN MASSACHUSETTS ELECTRIC COMPANY MILLSTONE NUCLEAR POWER STATION. UNIT NO. 2 DOCKET NO. 50-336

1.0 INTRODUCTION

By [[letter::B17413, Application for Amend to License DPR-65,revising TS Sections 3.3.2.1,3.4.6.2,3.4.8,3.6.2.1,3.6.5.1,3.7.6.1 & 3.9.15 as Result of Revised MSLB Analyses & Revised Determinations of Radiological Consequences of MSLB & LOCA|letter dated September 28,1998]], the Northeast Nuclear Energy Company, et al. (the licensee), submitted a request for changes to the Millstone Nuclear Power Station, Unit No. 2 Final Safety Analysis Report (FSAR). In 1997, the licensee issued a Design Change Record (DCR) to revise Sections 2.4.2 and 2.4.6 of Specification SP-M2-EE-0016, " Electrical Separation Specification - Millstone Unit 2," Rev. O. Specification SP-M2-EE-0016, Rev. O, requires 12 inches of separation between redundant wires / devices located in control panels, and does not address current industry standard regarding separation inside control panels. The licensee issued the DCR to change the minimum separation between redundant wires / devices located in control panels to 6 inches. The licensee based the 6-inch separation, in part, on IEEE Standard 384-1981. The licensee's DCR concluded that these changes did not involve an unreviewed safety question. The staff performed a safety system functionalinspection (SSFI) and issued a violation citing that 12 inches, and not 6 inches, is the approved electrical cable separation criteria in the panels for Millstone Unit 2. Therefore, by [[letter::B17413, Application for Amend to License DPR-65,revising TS Sections 3.3.2.1,3.4.6.2,3.4.8,3.6.2.1,3.6.5.1,3.7.6.1 & 3.9.15 as Result of Revised MSLB Analyses & Revised Determinations of Radiological Consequences of MSLB & LOCA|letter dated September 28,1998]], the licensee requested a license amendment to receive approval of the above mentioned changes to the FSAR because the licensee determined that the changes do involve an unreviewed safety question.

2.0 EVALUATION l

Prior to September of 1997, the FSAR stated, in Section 8.7.3.1, that redundant vital cables I

terminate on terminal blocks at least 12 inches apart; and, internal wiring of redundant vital circuits, and any associated devices, is separated by 12 inches. Where the minimum spatial separation of 12-inches is not feasible, noncombustible barriers or conduits are used to provide separation. Also, the barriers are properly supported for structural strength, and extended from top to bottom and front to back to a depth that provides a minimum of a 12-inch separation i

9901250374 990120

~

PDR ADOCK 05000336 P

PDR

~

g between channels. This formed the licensing basis for Millstone Unit 2, for the separation requirement inside control boards and panels for redundant vital circuits and associated devices.

The licensee reduced the minimum separation distance between redundant vital wires / devices inside control panels from 12 inches to 6 inches in accordance with IEEE Standard 384-1981, Sections 6.6.2 and 6.6.5. Section 6.6.2 of IEEE Standard 384-1981 states that where the control switchboard materials are flame retardant and an analysis is not performed, the minimum separation distance shall be 6 inches. In the event the above separation distances are not maintained, barriers shall be installed between redundant Class 1E equipment and wiring.

Regarding the flame requirements, the licensee states that wires used inside control panels meet the IEEE Standard 383 flame test requirements as a minimum and circuits are protected by circuit breakers, fuses, or other limiting devices; thus, the probability of a fire due to wiring overcurrent or short circuit is negligible. Wiring inside control panels is used for control and indication, and carries currents that do not generate appreciable heat. Control panels are located in environments that maintain acceptable temperatures within the control panels. Thus, damage to wires / devices due to fires or overheating is negligible. The revised FSAR Section 8.7.3.1 states:

Redundant vital cables terminate on terminal blocks at least six inches apart. Interr':;l wiring of redundant vital circuits, and any associated devices, is separated by L minimum of six laches. Where the minimum separation of six inches is not feasible, noncombustible barriers or conduits are used te prende separation.

l The barriers are properly supported for structurai Wength, and extended from top to l

bottom and front to back to a depth which providen a minimum of six inches separation between channels.

The staff has evaluated the licensee's submittal anu ocrmined that the changes of the cable separation from 12 inches to 6 inches are in accordance with Regulatory Guide (RG) 1.75-1978, Rev. 2. RG 1.75, Rev. 2 endorses IEEE Standard 3f,4-1974. IEEE Standard 384-1974 provides guidance for 6 inches of minimum separati)n between redundant Class 1E equipment and circuits intemal to the control boards. This is th a same guidance contained in IEEE Standard 384-1981 for wiring internal to the control t oards.

Based on the preceding evaluation, the staff concludos that the changes of cable separation requirements intemal to the control boards are safe because they are in accordance with current regulatory guidance contained in RG 1.75-1978. Therefore, the licensee's previously implemented FSAR changes are acceptable.

(

(

3.0 STATE CONSULTATION

in accordance with the Commission's regulations, the Connecticut State official was notified of the proposed issuance of the amendment. The State official had no comments.

l l

4 l.

- ~ ~~~

4.0 ENVIRONMENTAL CONSIDERATION

The amendment changes a requirement with respect to installation or use of a facility component located within the restricted area as defined in 10 CFR Part 20. The NRC staff has determined that the amendment involves no significant increase in the amounts, and no i

significant change in the types, of any effluents that may be released offsite, and that there is no j

significant increase in individual or cumulative occupational radiation exposure. The i

Commission has previously issued a proposed finding that the amendment involves no significant hazards consideration, and there has been no public comment on such finding (63 FR 59593, November 4,1998). Accordingly, the amendment meets the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Pursuant to 10 CFR 51.22(b) no environmental impact statement or environmental assessment need be prepared in connection with the issuance of the amendment.

5.0 CONCLUSION

The Commission has concluded, based on the considerations discussed above, that: (1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be cont'ucted in compliance with the Commission's regulations, and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.

Principal Contributor: N. Trehan Date: January 20, 1999 l

f 1

5 s

4

-_