. _ _ _, - - -,. - - - - -
. f.. 0%
og y I*.
UNITED STATE 8 g
j NUCLEAR REGULATORY COMMISSION WASHINGTON. D.C. 30046 4 001
\\*..../
January 22, 1998
)
Mr. James W. Langenbach Vice President and Director TH! 1 GPU Nuclear Corporation P.O. Box 480 Middletown PA 17057 0480
SUBJECT:
SAFETY EVALUATION OF LICENSEE RESPONSE TO GENERIC LETTER 95 07. ' PRESSURE LOCKING AND TH"RMAL BINDING OF SAFETY-RELATED POWER OPERATED GATE VALVES." THREE HiLE ISLAND NUCLEAR STATION. UNIT 1 (TAC NO. M93530)
Dear Hr. Langenbach:
On August 17, 1995, the NRC issued Generic Letter (GL) 95 07. " Pressure Locking and Thermal Binding of Safety Related Power Operated Gate Valves." to request that licensees take actions to ensure that safety related power operated gate valves that are susceptible to pressure locking or thermal binding are capable of perforining their safety functions.
By letter dated February 13. 1996. GPU Nuclear Corporation (GPUN) submitted its 180-day response to GL 95 07 for the Three Mile Island Nuclear Station. Unit 1 (THI-1).
The NRC staff reviewed the GPUN February 13. 1996, submittal, and requested additional information in a lotter dated August 22, 1996. By a letter dated Septentier 25, 1996. GPUN provided additional information in response to the NRC staff's request.
The NRC staff has reviewed the GPUN submittals of February 13 and September 25, 1996. The staff finds that GPUN has adequately addressed the requested actions discussed in GL 95 07 for THI-1. as discussed in the enclosed safety evaluation. This conpletes the NRC staff review of TAC No. M93530.
I
}
DfM E fM CBirl3 eppy
- g2ogggtggggg,,
P PDR ll,1 ll ll llljl,l ll m
n em j
k J. Langenbach' If you have any questions please contact me at 301 415 1402.
Sincerely.
Original signed by Timothy G. Colburn. Senior. Project Manager Project Directorate 1 3 Division of Reactor Projects 1/II Office of Nuclear Reactor Regulation Docket No. 50 289 1
i
Enclosure:
Safety Evaluation--
i cc w/ encl: See next page 1
Distribution 00:ket file:
'PUBLIC PDI-3 Rdg.
B. Boger i
i R. Eaton T. Clark T. Colburn-T. Harris (e mail SE only TLH3)
OGC' LACRS C. Hehl, RI S. Tingen R, Wessman DOCUMENT NAME-G:\\BUCKLEY\\TNI93530.LTR OFFICE PDI-3/PM_ =
PDI-3/LA PD&j/Y NAME-TColbd[
TC1 M b REhthn DATE I./2%98 7//d'/98:
l772/98 r
1 J. Langenbach Three Mile Island Nuclear Station, Unit No I cc:
Michael-Ross_
Wayne L. Schmidt Director, O&M, TMI Senior Resident inspector (THI-1) i GPU Nuclear Corporation U.S. Nuclear Regulatory Commission P.O. Box 480 P.O. Box 311 Middletown, PA 17057 Middletown, PA 17057 i
John C. Fornicola Regional Administrator Director, Planning and Region I Regul6 tory Affairs U.S. Nuclear Regulatory Commission GPU Nuclear Corporation 475 Allendale Road 100 Interpace Parkway ring of Prussia PA 19406 Parsippany, NJ 07054 Robert B. Borsum Jack S. Wetmore B&W Nuclear Technologies Manager, THI Regulatory Affairs Suite 525 GPU Nuclear Corporation 1700 Rockville Pike P.O. Box 480 Rockville, MD 20852 Hiddletown, PA 17057 William Dornsife, Acting Director Ernest L. Blake, Jr., Esquire Bureau of Radiation Protection Shaw, Pittman, Potts & Trowbridge Pennsylvania Department of 2300 N Street, NW.
Environmental Resources Washington, DC 20037 P.O. Box 2063 Harrisburg, PA 17120 Chairman Board of County Commissioners Dr. Judith Johnsrud of Dauphin County National Energy Committee Dauphin County Courthouse Sierra Club Harrisburg, PA 17120 433 Orlando Avenue State College, PA 16803 Chairman Board of Supervisors Peter W. Eselgroth, Region I of Londonderry Township U.S. Nuclear Regulatory Commission R.D. #1, Geyers Church Road 475 Allendale Road MioJ1etown, PA 17057 King of Prussia, PA 19406