Application for Request of Partial Issuance of Amend to License NPF-42,proposing TS SR Be Revised to Delete During SD Requirement & Reflect Appropriate Plant Conditions in Associated 3/4.7.3 Bases
ML20199G721
Person / Time
Site: Wolf Creek 
Issue date: 01/15/1999
From: Warren C
WOLF CREEK NUCLEAR OPERATING CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20199G725 List:
References
WO-99-0002, WO-99-2, NUDOCS 9901220389
Download: ML20199G721 (4)


Text

.

i

  • ~

e W4)NUCLEAROPERATING COR ciar. warren c

Vice President & Chief Operating Officer JAN 151999 WO 99-0002 U. S. Nuclear Regulatory Commission ATTN:

Document Control Desk Mail Station: Pl-137 Washington, D. C.

20555

Reference:

Letter ET 97-0050 dated May 15, 1997, from R.

A.

Muench, WCNOC, to USNRC

Subject:

Docket No. 50-482:

Request for Partial Issuance cf License Amendment on Component Cooling Water Gentlemen:

This letter requests the partial issuance of an amendment to Facility Operating License No. NPF-42 for the Wolf Creek Generating Station (WCGS), as discussed.with the acting NRC Project Manager on January 5, 1999.

Wolf Creek Nuclear Operating Corporation (WCNOC) requested an amendment to convert the current Technical Specifications to a set of Technical Specifications based upon the improved Standard Technical Specifications (NUREG-1431, Revision 1) as provided in the Reference.

Specifically, per this letter WCNOC is requesting that Technical Specification Surveillance Requirement (SR) 4.7.3b.

be revised to delete -the "during shutdown" requirement and reflect the appropriate plant conditions in the associated 3/4.7.3 Bases.

Deleting this wording is consistent with SR 3.7.7.2 and SR 3.7.7.3 and associated Bases of the improved Standard Technical Specifications.

This proposed change was justified in Description of Change (DOC) 08-03-LG in Attachment No. 13 of the Reference.

This request is based on recently identifying that Component cooling Water Pumps C and D are inoperable due to a set of contacts not being tested as required by Technical Specification Surveillance Requirement 4.7.3b.

Marked.up pages for the current WCGS Technical. Specifications and Bases are provided in Attachment II.

A summary of the commitments made in this submittal is provided in Attachment II.

WCNOC intends to implement this amendment within 30 days of NRC approval, t

9901220389 990115 PDR ADOCK 05000482 P

PDR

, PO, Box 411 ! Burhngton, KS 66839 / Phone: (316) 364 8831 An Equal Opportundy Empicyer M FNC/ VET

l'

+

t!O 99-00002 Page 2 of 2 If you should have any questions regarding this submittal, please contact me at (316) 364-4048, or Mr. Michael J. Angus at (316) 364-4077.

Very truly yours, Clay C. Warren CCW/dle Attachments cc:

V.

L. Cooper (KDHE), w/a W.

D. Johnson (NRC), w/a E.

W. Merschoff (NRC), w/a K. M. Thomas (NRC), w/a Senior Resident Inspector (NRC), w/a 1

m

._m

.-. _ _ _ ~.. - _. _ _.. _ _..

[,

l-l STATE OF KANSAS

)

)

SS COUNTY OF COFFEY

)

Clay C.

Warren, of lawful age, being first. duly sworn upon oath says that he is Chief Operating Officer of Wolf Creek Nuclear Operating Corporation; that j

he has read the foregoing document and knows the content thereof; that he has executed that same for and on behalf of saic Corporation with full power and authority to do so; and that the facts therein stated are true and correct to the best of his knowledge, information and belief.

By' Clay Warren Vice President and Chief Operating Officer day of M.

1999.

SUBSCRIBED and sworn to before me thi A

Not r 'Fublic ~

~>

JUUE A. DALE

20) loo 1 KsaryPub5c.S toof ansas

/

,My Appt.frpires /O ")O J u;2, Expiration Date f

1 I

l l-f

.i

l.

Attachment I to WO 99-0002 Page 1 of 4 ATTACID4ENT I PROPOSED TECHNICAL SPECIFICATION CHANGES CURRENT TEC11NICAL SPECIFICATIONS i

1