ML20199D904

From kanterella
Jump to navigation Jump to search
Forwards Draft, Peach Bottom Containment Event Tree Documentation. Review Incomplete.Final Rept Will Include Quantification
ML20199D904
Person / Time
Site: Peach Bottom  
Issue date: 02/10/1986
From: Benjamin A
SANDIA NATIONAL LABORATORIES
To: Rosztoczy Z
NRC
Shared Package
ML20199D891 List:
References
NUDOCS 8603240402
Download: ML20199D904 (1)


Text

.

- o-Albuquerque, New Meuco 87185 February'10, 1986 Mr. Zoltan Rosztoczy U.

S. Nuclear Regulatory Commission Mail Stop 266 7920 Norfolk Avenue Bethesda, MD 20814

Subject:

Peach Botton Containment Event Tree Documentation for IDCOR

Dear Zoltan:

'The enclosed writeup is a detailed description of the Peach

-Bottom containment event tree, which you requested for IDCOR.

Our internal review of the document is incomplete; however, the authors and I do not' object to your sending it.to IDCOR at this time.

Per our agreement, the present document does not include any quantification of the tree. Our final report on the Peach Bottom containment event tree will, of course, include quantification.

Sincerely, d

A~ f +

Allan S. Benjamin, Supervisor Reactor Safety Technology Division 6411 ASB:6411:0493B:mjs copy to (w/o enc 1)

NRC D. Pyatt NRC M. Ernst Technadyne C. Amos

-6410 J. Hickman 6415 E. Haskin 6415 M. Griesneyer 8603240402 960311 PDR ADOCK 05000277 P

PDR'