November 12, 1997 Mr. Michael E. Wangler

' Office of Transportation, Emergency Management, and Analytical Services, EM-76 U.S. Department of Energy 19901 Germantown Road Germantown, MD 20874

Dear Mr. Wangler:

This refa to your application dated October 30, 1995, as supplemented August 21, 1997, requesting an amendment to Certificate of Compliance No. 9932 for the Model No. UC-609 package.

In connection with our review, we need the information identified in the enclosure to this letter, Please advise us within 30 days from the date of this letter when this information will be provided. Additional information requested by this letter should be submitted in the form of revised pages.

If you have any questions regarding this matter, we would be pleased to meet with you and your st_ff.

Bernard White is the project manager for our review of your application.

Mr. White may be contacted at (301) 415-8515.

Sincerely, Original /s/ by Cass R.

Chappell, Chief Package Certification Section Spent Fuel Project Office Office of Nuclear Material Safety and Safeguards Docket No. 71-9932 fJbf b[kh@g{gggpy

Enclosure:

As stated To receive a copy c tnis document.. indicate in the box:

"C" - Copy without attachment / enclosure

'E' - copy with attachment / enclosure "N" - No copy 0FC P0 E

SFP0 Sff0,_

SFP0 C-

,S P0 6

ffLYang NLbhood

((kRZiegler C((ndppell NAME BHWhite lL 19 /97 N/lo/97 Il //0/97

// / /497

/

DATE p /10/97 L

Distribution:

NRC PDR NRC File Center NMSS r/f SFP0 r/f pTD3')

J0020 ll!!I ll!!,1111,Ill, ll

~

9711210023 971112 PDR ADOCK 07109932 C

PDR

t l

November 12, 1997

' Mr. Michael E. Wangler Office of Transportation, Emergency Management, and Analytical Services, EM-76 U.S. Department of Energy 19901 Germantown Road Germantown, MD 20874

Dear Mr. Wangler:

This refers to your application dated October 30, 1995, as supplemented August 21, 1997, requesting an amendment to Certificate of Compliance No. 9332 for the Model No. UC-609 package.

In connection with our review, we need the information identified in the enclosure to this letter.

Please advise us within 30 days from the date of this letter when this information will be provide.d. Additional information requested by this letter should be submitted in the form of revised pages.

If you have any questions regarding this matter, we would be pleased to meet with you and your staff.

Bernard White is the project manager for our review of your application.

Mr. White may be contacted at (301) 415-8515.

Sincerely, Original /s/ by Cass R.

Chappell, Chief Package Certification Section Spent Fuel Project Office Office of Nuclear Material Safety and Safeguards Docket No. 71-9932

Enclosure:

As stated To receive a copy of this document, indicate in the box: "C" - Copy without attachment / enclosure "E' - copy with attachment / enclosure 'N' - No copy M P0 E

SFP0 6

SED, _

E SFP0 C.

,SFP0 6

0FC NAME BHWhite LYang NLdkod

[NRZiegler C M pell DATE B/P/97 11/10/97 Il/P/97 Il //2/97

// / /2fg7 Distribution:

NRC PDR NRC File Center NMSS r/f SFP0 r/f

t 71-9932 Encl. to ltr. dtd.

11/12/97

~

1.

Provide :opies of the following drawings which were listed in Table 1 of your supplement dated August 12, 1997:

a.

AAA75-ll3591, Rev. 00, b.

AAA75-104814, Rev. CH, c.

AAA75-lC4817, Rev. OG, d.

AAA77-104162, Rev. OC, e.

AAA77-104163, Rev. 00, and f.

AAA91-107485, Rev. OB.

2.

Identify all changes that have been madr to these drawings compared to the earlier versions of these drav'ngs that wsrs included in your October 30, 1995, submittal. Show that the changes do not affect the ability of the package to meet the requirements of 10 CFR Part 71.

3.

The application contains too many fcbrication drawings.

The drawings show many details and dimensions which are not important to safety.

The application should be revised to include a smaller number of engineerinn drawings that are suitable for reference in a Certificate of Complian, The drawings should show the general arrangement of the package, its principle features, and the design of safety related components. The drawings should contain the following information:

a.

dimensions and toleri.as important to safety, b.

materials of construction, c.

applicable codes or standards for fabrication of safety-related components, d.

size, type, and locasion of safety related welds and methods of nondestructive examination, e.

torque requirements for closure bolts and othat threaded devices, f.

total weight of the package, and g.

location of the tamper indication feature.

-