hrn a MEMORANDUM FOR:

C. J. Paperiello, Director, Division of Reactor Safety J. A. Hind, Director, Division of Radiation Safety and Safeguards FROM:

Charles E. Norelius, Director, Division of Reactor Projects

SUBJECT:

. MASTER INSPECTION PLAN - DAVIS-BESSE Enclosed for your information and use is the Master Inspection Plan (MIP) for the Davis-Besse facility. The plan was developed using inputs provided from DRS and DRSS.

In addition, the frequency and schedule of our inspections was developed based on improvements noted in the licensee's performance since the Loss of Feedwater Event that occurred on June 9, 1986. These improvements were noted during our Region III inspections and also during inspections conducted by I & E and NRR (EQ inspections and maintenance assessment inspections).

. The enclosure is a two-year inspection plan for Davis-Besse. This plan will be modified as new problems develop or significant improvements are noted in the areas of concern.

Attachments 1 thru 4 are listings of open items, Course of Action (C0A) commitments, Performance Enhancement Program (PEP) items, SALP IV open items and major activities. These items are scheduled for closure prior to unit restart, which currently.is planned for October 15, 1986.

Inspection of these.

I items has been coordinated with the responsible divisions.

A is Region III's plan for monitoring the licensee's System Review and Test Program (SRTP) activities. Lead responsibility for this program has been assigned to DRS including contractor assistance. provides an outline of the augmented inspection that is planned during restart and operation of the unit.

It is anticipated that shift coverage will be provided for approximately two weeks during unit startup and initial' operation.

' is the total listing of Toledo Edison's commitments made in

'their C0A. The C0A is the licensee's response to NRR's 10 CFR 50.54f letter.

We intend to verify completion of approximately 30% of the items in this listing. The specific items planned for inspection and the responsible division are contained in Attachment 2.

For the remainder of the items, we plan to monitor their status.

8606180259 860612~

PDR ADOCK 05000346 O

PDR.

g 32s1

Multiple Addresses 2 is the Davis-Besse Study Group Report observations and findings.

We intend to monitor resolution of the concerns identified in this report.

If you have any questions or comments regarding this master inspection plan, contact myself or Nick Jackiw.

Charles E. Norelius, Director Division of Reactor Projects

Enclosure:

Davis-Besse Master Inspection Plan Attachments:

1.

Open Items, Violations and Unresolved Items 2.

Course of Action Items Selected for Inspection 3.

Performance Enhancement Program and SALP Items 4.

Major Activities-Davis Besse 5.

Davis-Besse Restart Test Program 6.

Augmented Inspection During Restart and Operations 7.

Course of Acticn Items-Total Listing 8.

Study Group Report-Observations and Findings cc w/ enclosure:

J. G. Keppler A. B. Davis J. Harrison W. Hehl I

D. Danielson W. Shafer M. Phillips W. Axelson l

M. Ring i

F. Hawkins l

M. Schumacher l

E. Schweibinz l

D. Kosloff l

R. Greger P. Byron A. DeAgazio I

cc w/ enclosure, w/ attachments:

C. J. Paperiello J. A. Hind RIII m RII RI No 1

Gu) and Jack #/c s

'6s i

\\

(,{tM

?

t

s.

F /:
RSN : May/: J ul / : Sep/: Nov/: Jin/ : Ma r/ : May/ : J ul / : Sep/ : Nov/ : J:n/: Mar /:
Mod.:

/:

86/ :

/:

/:

/ :87/ :

/:

/:

/:

/:

/ :88/. : / :

No. :

Description

/ :
/ : / : / : / : / : / : / : / : / : /: / : / :
/ P : DIV : SEC : SCH : /J un: /Aug: /0c t: /Dec: /Feb: /Apr: /J un: /Aug: /0ct: /Dec: /Feb: /Ap r:
* /:
30703: Management Meeting -
./:
ROU :
Ent. & Exit Interviews : / : ALL : ALL : TINE :NOT TO BE TRACKED :

i

/B&M:
W /:

5 :

35610:10 CFR Part 21 Insp.

/:

NO :
/ : DRP :
/ S :
A /:

9 :

35701:QA Prog.--Annual Review:

/:

11/86:
/ : DRS : QAPS:
/ B :
W /:

3 :

35751:QA/QC Admin. Program

/:

NO :
/ : DRS : QAPS:
/ S :
-W /:
36700:Org. & Admin.

/:

6/86 :
/ : DRP :
/S:
A /:
3/86 :
37700: Design Changes & Modif.:

/:

3/B7 :
/ : DRP :
/ 8 :
  1. 1 is May 1986
  • Ecch Inspection t

I PAGE 1 Updated to 2515 change of 09/17/84 Facility: DAVIS-BESSE 1

Revision Date

F /:
RSN : May/: J ul /: Sep/: Nov/: J r n/: Ma r/ : May/: J ul /: Sep/: Nov/: J: n/ : Mar /:
Mod.:
/:
86/ :

/:

/:

/ :87/ :

/:

/:

/: /: / :88/ : /:

No. :

Description

/ :
/ : / : / :- / : / : / : / : '/ - : / :. / : /_: / :
/ P : DIV : SEC : SCH : /Jun: /Aug: /Oct: /Dec: /Feb: /Apr: /Jun: /Aug: /Oct: /Dec: /Feb: /Apr:
W /:

5 :

37701: Facility Modifications :

/:

NO :
/ : DRP :
/ S :
W /:

5 :

37702: Design Changes & Modif.:

/:

NO :
/ : DRS : QAPS:
/ S:
W /:

3 :

37703: Tests & Experiments as :

/:

NO :
needed and 3 years
/ : DRS : QAPS:
/ S :
W /:

5 :

38701: Procurement Control

/:

NO :
Program
/ : DRS : QAPS:
/ S :
W /:

5 :

38702: Receipt, Storage and

/:

NO :
Handling of Equipment : / : DRS : QAPS:
Program S:
W /:

3 :

39701: Records Program

/:

NO :
/ : DRS : QAPS:

S:

W /:

3 :

39702: Document Control Prog. :

/:

NO :
/ : DRS : QAPS:
/ S :
W /:
10 :
40700: Review and Audits

/:

10/86:
Including Site Review : / : DRP : RI
Committee
/ B :
  1. 1 is May 1986 PAGE 2 Updated to 2515 change of 09/17/84 Facility: DAVIS-BESSE i

Revision Date i

F /:
RSN : May/ : J u l /: Sep/: Nov/ : J rn/: Mar / : May/: J u l / : Sep/: Nov/: J ; n/: Mar /:
Mod.:

/:

86/ : /:

/:

/ :87/ :

/:

/: /:

/: / :88/ :

/:

HNo. :

Description

/ :
/ : / : / : / : / : / : / : / :/ : / : / : / :
/ P : DIV : SEC : SCH : /J un: /Aug: /0ct: /Dec: /Feb: /Ap r: /J un: /Aug: /0ct: /Dec: /Feb: /Ap r:
W /:
10 :

i40701:0ffsite Review.

/:
10/86:
Committee
/ : DRS : QAPS:
/-S :
W /:

5 :

40702: Audit Program

/:

NO :
/ : DRS : QAPS:
/ S :
W /:

5 :

40703:0ffsite Support Staff :

/:

NO :
/ : DRS : QAPS:
/ S:
W /:

5 :

40704: Implementation, Audit :

/:

NO :
Program
/ : DRP :
/ S :
A /:

9 :

41400:Non-Licensed Staff

/:

OLS :11/86:
Training
/ : DRS : QAPS:
/M :
A /:

9 :

41701: Licensed Operator

/:

OLS :11/86:
Training
/ : DRS : QAPS:
/ B :
W /:
12 :
42700: Procedures

/:

10/86:
/ : DRP :
/ S :
W /:

4 :

50095: Spent Fuel Storage

/:

NO :
Racks Modification
/ : DRP :
/ S:
  1. 1 is May 1986
  • DRS HAS LEAD-ALL DIVISIONS HAVE PAGE 3 Updated to 2515 change of 09/17/84 LIMITED RESPONSIBILITIES Facility: DAVIS-BESSE R: vision Date e
F /:
RSN : May/: Jul /: Sep/: Nov/: Jrn/: Mar /: May/: Jul /: Sep/: Nov/: Jrn/: Mar /: '

i Mod.:

/:

=:

86/ :' / :./ :./.:87/ : /: '/;: /: : / -:' J/ :88/ :/ :

.: No. :

Description

/ :
/.::/ :-/ : / : /.: / : / ::/ ': /.::./' : / ':'/ ':

~

/ P :-DIV : SEC : SCH : /Jun: /Aue: /Oct: /Dec: /Feb: /Apr: /Jun: /Aue: /Oct: /Dec: /Feb: /Apr:
W /:
55700: Welding.
- /:

. /.. DRS. M&PS.

/ S:

~ :

W /:

3-:

56700: Calibration
-/ :
NO. ' :
/ : DRS : QAPS:
/ S :
W /:
57700:Non-Destructive

/:

Examination
/ : DRS : M&PS:
/-S :
W /:

5 :

60705: Preparation for

/:

NO :
Refueling-
/ : DRS : OPS :
/ S :
W /:

5 :

60710: Refueling Activities

/:

NO

./. DRS. OPS.

~
/ S:
W /:

9 :

61700: Surveillance
./ :
11/86:
/ : DRS : QAPS:
/ S :
OPS :
W /:
11 :
61701: Surveillance Refueling :

/:

12/87:

/

DRP

/ S :
W /:

5 :

61702: Surveillance-Core

/:

' NO :

.: Power Distrib. Limits : / : DRS': TPS :

/ S :
  1. 1 is May 1986 PAGE 4 Updated to 2515 change of 09/17/84 Ftcility: DAVIS-BESSE R vision Date
F /:
RSN : May/: J u l /: Sep/: Nov/: J:.n/ : Mar /: May/: J u l /: Sep/: Nov/: J n/: Mar /:
Mod.:
/:
86/ :

/:

/:

/ :87/-:

/:

/:

/: / : / :88/ :

/:

No. :

Description

/ :
/ : / : / : / : / : / : / : / : / : / :/ : / :
/ P : DIV : SEC : SCH : /Jun: /Aug: /0ct: /Dec: /Feb: /Ap r: /J un: /Aug: /0ct: /Dec: /Feb: /Ap r:
W /:
61703: Calibration - Local

/:

Power Range Monitors
/ : DRS : TPS :
/ S :
W /:
5/3 :
61704:APRM Calibration

/:

NO :
/ : DRS : TPS :
/ S :
W /:
5/3 :
61705:Incore/Excore Detector :

/:

NO
Calibration
/ : DRS : TPS :
/ S :
W /:
5/3 :
61706: Core Thermal Power

/:

NO :
Evaluation
/ : DRS : TPS :
/ S :
W /:
10 :
61707: Determination of
/:
ROU- :
Reactor Shutdown Margin: / : DRP :
TINE :
/B&M:
W /:
5/3 :

-61708: Isothermal Temperature : /:

NO :
Coefficient of
/ : DRS : TPS :
Reactivity Measurement :/ S :
W /:
5/3 :
61709: Power Coefficient of
/:
NO :
Reactivity (PWR)
/ : DRS : TPS :
/ S :
W /:
5/3 :
61710: Control Rod Worth

/:

NO :
Measurement
/ : DRS : TPS :
/ S :
  1. 1 is May 1986 PAGE 5 Updated to 2515 change of 09/17/84 Ftcility: DAVIS-BESSE R2 vision Date t
F /:
RSN : May/: J ul /: Sep/: Nov/: J;n/: Mar /: May/: J ul /: Sep/: Nov/: J ;n/: Mar /:
Mod.:

/:

86/ :

/: /:

/ :87/ :

/:

/:

/ :, / : / :88/ :

/:

No. :

Description

/:
/ : / : / :. / : / : / : / : / : / : / : /: / :
/P: DIV : SEC : SCH :/Jun:/Aug:/Oct:/Dec:/Feb:/Apr:/Jun:/Aug:/Oct:/Dec:/Feb:/Apr:
W /:
5/3 :
61711: Target Axial Flux

/:

Difference Calculation : / S: DRS : TPS :
(W-NSSS)
/B&M:
2yr/:
4 :
61720: Containment Leak Rate :

/:

Test
/ : DRS : OPS :
/ B :
W /:

5 :

61724: Test and Measurement
/:
NO :
Equipment Program
/ : DRS : QAPS:
/ S :
* /:

3 :

61725: Surveillance Testing & :

/:

NO :
Calibration Control
/ : DRS : QAPS:
Program
/ B :
M /:
10 :
61726:Mcqthly Surveillance
/:
R00- :
Observations
/ : DRP :
TINE :
/ M :
W /:
61729: Routine Surveillance- :

/:

Pipe Support and
/ : DRS : M&PS:
Restraint Systems
/ S :
2yr/:
10 :
62700: Maintenance

/:

4/88 :
/ : DRP :
/ S :
  1. 1 is May 1986 83 yr.

PAGE 6 Updated to 2515 change of 09/17/84 Ftcility: DAVIS-BESSE R: vision Date

F /:
RSN : May/: J u l /: Sep/: Nov/: J :n/: Mar /: May/: J ul /: Sep/: Nov/: J :n/: Mar /: '
Mod.:

/:

86/ :

/: /:

/ :87/':

/:

/:

/: / :. / :88/ : -/:

No. :

Description

/ :
/ : /- : / : / : / : / : / : / : / : / : / : / :
/ P : DIV : SEC : SCH : /J un: /Aug: /Oct: /Dec: /Feb: /Apr: /J un: /Aug: /Oct: /Dec: /Feb: /Ap r:
* /:

9 :

62702: Maintenance Program
/:
11/86:
/ : DRS : QAPS:
/ B :
M /:
10 :
62703: Monthly Maintenance
/:
ROU- :
Observation
/ : DRP :
TINE :
/ M :
W /:
64703: Fire Prevention /
/:
/ : DRS : OPS :
/ S:
A /:
64704: Fire Prevention /

/:

Protection Prog. Imple.: / : DRS : OPS :
/ B :
W /:

5 :

65051: Low Level Radioactive :

/: DRSS:

NO :
Waste Storage Fac.
/ : ALL : FRPS:
/ S :
  1. 1 is May 1986 23 yr.

PAGE 7 Updated to 2515 change of 09/17/84 Facility: DAVIS-BESSE R: vision Date

~

. Mod.:

. : F /:

RSN : May/: Jul /: Sep/: Nov/: Jin/: Mar /: May/: Jul /: Sep/: Nov/: J: n/: Mar /:
./:-
86/ :- /: / :' / :87/ :_ /: : /: '/:_ / : / :/ : / :-

/ ': /:88/:: /:::

No. :.

Description

/ :
/ : / : / :-/. : / -:' / : / : / :

. :/ P : DIV : SEC : SCH : /Jun: /Aue: /Oct: /Dec: /Feb: /Apr: /Jun: /Aue: /Oct: /Dec: /Feb: /Apr:

" /:
10 :
71707: Operational Safety

/:

ROU- :
1
Verification
/ : DRP':

' TINE :

/B&M:
BM /:
10 :
71710:ESF System Walkdown
/:
ROU :
/ :' DRP :
TINE _:
/ B:
.R /:
10 :
71711: Review of Plant

/:

12/86:
Operations
/ : DRP :
/ B :
W /:

.: 10

71714: Cold Weather

/:

11/86:

~:

Preparations
/ : DRP :
11/87:
/ B :
R /:
5/3 :
72700:Startup Testing -

/:

NO :
Refueling
/ : DRS : TPS :
/ 8 :
W /:
12 :.
72701:Startup Testing - New :

/:

ROU :
or Modified System
/ : DRS : TPS : TINE :-
/ B :
W /:
73051: Inservice Inspection - : /:
Review of Program
/ : DRS : M&PS:
/ S :
W /:
73052: Inservice Inspection - : /:
Review of Procedures
/ : DRS : M&PS:
/ S:
  1. 1 is May 1986
  • D/WK/BWK
    • DRS MDNITROING LICENSEE'S SRTP.

PAGE 8 Updated to 2515 change of 09/17/84' Facility: DAVIS-BESSE Rzvision Date

.F-/:
RSN, : May/: Jul /: Sep/: Nov/: J: n/: Mar /: May/: Jul /: Sep/: Nov/: J;n/: Mar /:'
Mod.:
/:

. : 86/. : -/ :'./ :. / :87/ : /: / : - / :- - / :. / :88/': /':

'.. ' : / '

/ L: / : / : / :.

No. :

Description

/ ':
/ :../ : /: / :/ : / ': /
/ P : DIV : SEC : SCH ': /Jun : /Aue: /Oct: /Dec: /Feb: /Apr: /Jun: /Aue: /Oct: /Dec: /Feb: /Apr: -
W /:
13 :
79501: LWR Water Chemistry
/:

~ :

9/86 :
Control and Chemical
/ :DRSS : RECS :
Analysis
/ S :
W /:
13 :
79502: Plant Systems Affecting:

/:

9/86 :
Plant Water Chemistry :./ :DRSS : RECS :
/S :
A /:
10 :
79701: LWR Water Chemistry

/:

9/87:

~:

Control and Chemical
/ :DRSS : RECS :
Analysis
/ B :
  1. 1 is May 1986 b

PAGE 8a Updated to 2515' change of 09/17/84 Ftcility: DAVIS-BESSE R2 vision Date

-. ~.. -

., ~ -

e4 1

F /:
RSN :May/:Jul/:Sep/:Nov/:J;n/: Mar /:May/:Jul/:Sep/:Nov/:J:_n/: Mar /:

- : Mod.:

/:

86/ :

/: ' / ':

/ :87/.:-//.:.~ / :./:. / :. / :88/ : '/ :

No.-:

-Description

/ :

.': /: / '

/ ~ ~; / ' :-/. : -/. : /..: / ':D / : /. : -/- i / :

/ P : DIV : SEC : SCH : /Jun : /Aue: /Oct: /Dec: /Feb : /Ap r: /Jun: /Aug: /Oct: /Dec: /Feb: /Ap r:
W /:
73753: Inservice Inspection

/:

i

Observation of Work and: / : DRS : M&PS:.

i

Work Activities-
/ S :

^:

W /:

I

73755: Inservice Inspection - :

/:

Data Review & Eval.
/ : DRS : M&PS:
/ S :

J-

W /:
6a :
80521: Radiological Environ.

/:

NO :
Monitoring-
/ : DRSS: RECS :

6

/ S :

l

* /:
11 :
80721: Radiological Environ.

/:

9/86 :

4

Monitoring
/ : DRSS: RECS :
/-B :
A**/:

i

81018: Security Plan and

/:

4

Implementing Procedures: / : DRSS: PSS :
/ M :

i

A**/:

i

81020: Management

/:

Effectiveness
/ : DRSS: PSS :
/ M :

t

A**/:

i

81022: Security Organization -:

/:

i

Management
/ : DRSS: PSS :
/ M :

i

A**/:
81034: Security Program -

/:

Audit
/ : DRSS: PSS :
/ B :
  1. 1 is May 1986
  • Biennial
    • See TI 2500/08 PAGE 9 Updated to 2515 change of 09/17/84

[

j

' r 4

Ftcility: DAVIS-BESSE

- j R2 vision Date 1

I t

4

}

a 4

r,-

F /:
RSN : May/ : J ul /: Sep/: Nov/: J i n/: Ma r/: May/: J ul /: Sep/: Nov/: J in/: Mar /:
Mod.:
/:
86/ : /:

/: / :87/ :

/:

/.: /: /:

/ :88/ :' / :

No. :

Description

/ :
/ : / : / : / : / : / : / : / : /: / : / : /:
/ P : DIV : SEC : SCH : /Jun: /Aug: /Oct: /Dec: /Feb: /Apr: /J un: /Aug: /Oct: /Dec: /Feb: /Apr:
A* /:
81038: Records and Reports

/:

/ : DRSS: PSS :-
/ M :
A*/:
81042: Testing and Maintenance:

/:

/ : DRSS: PSS :
/ B :
A* /:
81046: Locks, Keys, and

/:

Combinations
/ : DRSS: PSS :
/ B :
A*/:
81052: Physical Barriers -

/:

Protected Areas
/ : DRSS: PSS :
/ M :
A*/:
81054: Physical Barriers -

/:

Vital Areas
/ : DRSS: PSS :
/ M :
A*/:
81058: Security System Power :./:
Supply
/ : DRSS: PSS :
/ B :
A* /:
81062: Lighting

/:

/ : DRSS: PSS :
/ B :
A*/:
81064: Compensatory Measures :

/:

/ : DRSS: PSS :
/ B :
  1. 1 is May 1986
  • S2e TI 2500/08 PAGE 10 Updated to 2515 change of 09/17/84 Fccility: DAVIS-BESSE R: vision Date
F /:
RSN : May/: J u l /: Sep/: Nov/: Jin/: Ma r/ : May/: J ul / : Sep/: Nov/: J:;n/: Mar /:
Mod.:

/:

86/ : /:

/:

/ :87/ :

/:

/:

/: /: / :88/ :

/:

No. :

Description

/ :
/ : / : '/ : / : / : / : / : / : /: / : / : / :
/ P : DIV : SEC : SCH : /J un: /Aug : /Oct: /Dec: /Feb: /Ap r: /Jun: /Aug: /Oct: /Dec: /Feb: /Ap r:
A*/:
81066: Assessment Aids

/:

./

DRSS. PSS.

/ M :
A*/:
81070: Access Control -

/:

Personnel
/ : DRSS: PSS :
/B:

AR/

ns

81072: Access Control -
/ :
Packages
/ : DRSS: PSS :
/ B:
A*/:
81074: Access Control -
/ :
Vehicles
/ : DRSS: PSS :
/ M:
A*/:
81078: Detection Aids -

/:

Protected Areas
/ : DRSS: PSS :
/ M :
A*/:
81080: Detection Aids -

/:

Vital Areas
/ : DRSS: PSS :
/ M :
A*/:
81084: Alarm Stations

/:

/ : DRSS: PSS :
/ M :
A*/:
81088: Communications

/ :

/ : DRSS: PSS :
/ M :
  1. 1 is May 1986 "See TI 2500/08 PAGE 11 Updated to 2515 change of 09/17/84 Ftcility: DAVIS-BESSE R; vision Date

,: F /:

.:RSN : May/: Jul /: Sep/: Nov/: J:n/: Mar /: May/: Jul /: Sep/: Nov/: J;n/: Mar /:

Mod.:
/:
86/ :./:

/: / :87/ :' /:. / -: '/ ':

/: / :88/ :

/. :.

No. :

Description

/ -:
/ : / : / : / : / : /: / : /: /. ':' / :/ : /:
/ P : DIV :- SEC : 'SCH :/Jun:/Aue:/Oct:/Dec:/Feb:/Apr:/Jun:/Aue:/Oct:/Dec:/Feb:/Apr:
A" /:
81501: General Requirements

/:

for Personnel
/: DRSS: PSS :
/ B :
A" /:
81601: Safeguards Contingency :

/:

Plan Implementation
/ : DRSS: PSS-:.
Review
/ B :
W /:

-:81810: Physical Protection /

/:

~

Safeguards Information : / : DRSS: PSS :
/ S :
A /:
8 :
82201: Emergency Detection

/:

4/86 :
and Classification
/ : DRSS: EPS :6/86 :
/ B :
A /:

8 :

82202: Protection Action
./:
4/86 :
Decision Making
/ : DRSS: EPS :6/86 :
/ B :
A /:
8 :
82203: Notifications and
/:

~:'

4/86 :
Communications

.: / : DRSS: EPS :6/86 :

/ B :
A /:
8 :
82204: Charges to Emergency

/:

4/86 :
Preparedness Program
/ : DRSS: EPS :6/86 :
/ 8 :
A /:

8 :

82205: Shift Staffing and
/:
4/86 :
Augmentation
/ : DRSS: EPS :6/86 :
/ B :
  1. 1 is May 1986
  • Se2 TI~2500/08 PAGE-12 Updated to 2515 change of 09/17/84 Ftcility: DAVIS-BESSE R: vision Date
F /:
RSN : May/: J ul /: Sep/: Nov/: J nn/: Ma r/: May/: J ul /: Sep/: Nov/: Jan/: Ma r/:
Mod.:

/:

86/ : /: /: / :87/ :

/: /: /: /: / :88/ : /:

No. :

Description

/ :
/ : / : / : / : / : / : / : / : / : / : / : / :
/ P : DIV : SEC : SCH : /J un: /Aug: /Oct: /Dec: /Feb: /Apr: /Jun: /Aug: /Oct: /Dec: /Feb: /Ap r:
A /:
8 :
82206: Knowledge and Perf.

/:

4/86 :
of Duties (Training)
/ : DRSS: EPS :6/86 :
/ B :
" /:
8 :
82207: Dose Calculation

/:

and Assessment
/ : DRSS: EPS :
/ B :
^ /:
8 :
82209:Public Information

/:

9/86 :
Program
/ : DRSS: EPS :
/ B:
A /:

8 :

82210:Licentre Audits and
/:
4/86 :
Quality Assurance
/ : DRSS: EPS :6/86 :
/ B :
A /:-

8 :

82301: Observation / Evaluation :

/:

9/86 :
of Exercises for
/ : DRSS: EPS :
Nuclear Power Reactors :/ B :
Radiation Protection,
W /:
6a :
83522: Plant Chemistry, Rad- :

/:

FRPS: NO :
waste & Environ., Org. : / : DRSS: RECS:
& Management Controls :/ S :
Radiation Protection,
W /:
6a :
83523: Plant Chemistry, Rad- :

/:

FRPS: NO :
Trans. & Environmental : / : DRSS: RECS:

i

Trna. & Qualifications :/ S :
W /:
6a :
83524: External Occupational

/:

NO :
Exposure Control &
/ : DRSS: FRPS:
Personal Dosimetry
/ S :
  1. 1 is May 1986
  • Biennial PAGE 13 Updated to 2515 change of 09/17/84 Fccility: DAVIS-BESSE R; vision Date
F /:
RSN : May/: J ul /: Sep/: Nov/: Ja n/: Ma r/: May/ : J u l /: Sep/: Nov/: Jan/: Ma r/:
Mod.:

/:

86/ :

/:

/:

/ :87/ : /: /:

/: /: / :88/ : /:

No. :

Description

/- :
/ : / : / : / : / : / :- / : / : / : / : / : / :
/ P : DIV : SEC : SCH : /Jun: /Aug: /Oct: /Dec: /Feb: /Ap r: /J un: /Aug: /Oct: /Dec: /Feb: /Ap r:
W /:
6a :
83525: Internal Exposure

/:

NO :
Control & Assessment
/ : DRSS: FRPS:
/ S:
W /:
6a :
83526: Control of Radioactive :

/:

NO :
Matl's & Contamination : / : DRSS: FRPS:
Surveys & Monitoring
/ S:
W /:
6a :
83527: Facilities & Equipment : /:
NO :
/ : DRSS: FRPS:
/ S :
Radiation Protection,
A /:
10* :
83722: Plant Chemistry & Rad : /:
FRPS:8/86 :
waste, Organization & : / : DRSS: RECS:
Management Controls
/ B :
Radiation Protection,
A /:
10* :
83723: Plant Chemistry, Rad- : /:
FRPS:8/86 :
waste & Transportation : / : DRSS: RECS:
Trna. & Qualifications :/ B :
A /:
10" :
83724: External Occupational

/:

8/86 :

-Exposure Control and

/ : DRSS: FRPS:
Personal Dosimetry
/ B :
A /:
10* :
83725: Internal Exposure

- : /:

8/86 :
Control & Assessment
/ : DRSS: FRPS:
/ B :
A /:
10* :
83726: Control of Radioactive :

/:

8/86 :
Matl's & Contamination : / : DRSS: FRPS:
Surveys & Monitoring
/ B :
  1. 1 is May 1986 PAGE 14 Updated to 2515 change of 09/17/84 Fccility: DAVIS-BESSE R: vision Date

~:.

F /:
RSN : May/: Jul /: Sep/: Nov/: J;n/: Mar /: May/: Jul /: Sep/: Nov/: Jan/: Mar /:
Mod.:
/':
86/ ': -/ :

/:. / :87/ : / :

/ :- / :

/ :. /.:88/ :

/:

No. :

Description

/ :
/' : /. ':- / : / -: / : /- :. / :.'/' :./. : /' :i/ : /:
/ P : DIV : SEC : -SCH :/Jun:/Aua:/Oct:/Dec:/Feb:/Apr:/Jun:/Aue:/Oct:/Dec:/Feb:/Apr:
A /:
2 :
83727: Facilities & Equipment : / :-
NO. :
/ : DRSS: FRPSi-
/ B :
A /:
10" :
83728: Maintaining Occupa-

/:

8/86 :
tional Exposures ALARA : / :.DRSS: FRPS:

~/B:

-W /:
6a :

.:83729: Occupational Exposure :

/:

NO :
During Extended Outages: / : DRSS: FRPS:
/ B :
W /:
6a :
84522: Solid Wastes

/:

NO :
/ : DRSS: FRPS:
c
/ S :
W /:
6a :
84523: Liquid & Liquid Wastes :

/:

NO :
/ : DRSS: FRPS:
/ S :
W /:
6a :
84524: Gaseous Waste System

/:

NO :
/ : DRSS: FRPS:
/ S :
W /:
6a :
84525: Radiological & Chemical: /:
N0' :
Confirmatory
/ : DRSS:IMEPS:
/ S :
A /:
10" :
84722: Solid Wastes

/:

8/86 :
/ : DRSS:'FRPS:
/ B :
  1. 1 is May 1986
  • MINIMUM PROGRAM PORTION ONLY PAGE 15 Updated to 2515 change of 09/17/84 Facility: DAVIS-BESSE R; vision Date
F /:
RSN : May/; J ul /: Sep/: Nov/: J:;n/: Ma r/: May/: J ul /: Sep/: Nov/: Jan/: Mar /:
Mod.:

/:

86/ :

/: /:

/ :87/ :

/:

/:

/:

/:

/ :88/':

/:

No. :

Description

/ :
/ : /: / : / : / : / : / : / : / : / : / : / :
/ P : DIV : SEC : SCH : /Jun: /Aug: /Oct: /Dec: /Feb: /Apr: /J un: /Aug: /Oct: /Dec: /Feb: /Apr:
A /:
10" :
84723: Liquids & Liquid Wastes:

/:

8/86 :
/ : DRSS:.FRPS:
/ B :
A /:
10" :
84724: Gaseous Waste System

/:

8/86 :
/ : DRSS: FRPS:
/ B :
A /:

2 :

84725: Radiological & Chemical:

/:

9/86 :
Confirm. Measurements : / : DRSS: RECS:
/ B :
Radioactive Wast Mget. : W /:
6a :
84850: Inspection of Waste

/:

FRPS: NO :
Generator Requirements : / : DRSS:
of 10CFR20 & 10CFR61
/ S :
W /:
85102: Materials Control and :

/:

Accounting
/ : DRSS: PSS :
/ S:
W /:

4 :

86700: Spent Fuel Pool

/:

NO :
Activities
/ : DRP :
/ S :
A /:

2 :

86721: Transportation

/:

NO
/ : DRSS: FRPS:
/ B :
W /:
6a :
86740: Transportation

/:

NO :
Activities
/ : DRSS: FRPS:
/ S :
  1. 1 is May 1986
  • MINIMUM PROGRAM PORTION ONLY i

PAGE 16 Updated to 2515 change of 09/17/84 i

Facility: DAVIS-BESSE R: vision Date

F /:
RSN : May/: Jul /: Sep/: Nov/: J;n/: Ma r/: May/: J ul /: Sep/: Nov/: Jan/: Mar /:
Mod.:

/:

86/ ' : /: /. :, / :87/ :~ /.:

/: /. :. / : :. / : 88/. :. / : -

No. :

Description

/ :
/.: / '

/.: / : / : '/ : /~ :'/ ': /f :' /..: /: /:

/ P : DIV : SEC : SCH : /Jun: /Aug: /Oct: /Dec : /Feb : /Apr: /Jun: /Aug: /Oct: /Dec: /Feb: /Apr:
W /:-
10 :-

i90712:Inoffice Review of

/:
YES :
Event Reports
./ : DRP :

. :NOT TO BE TRACKED :

/ 8 :
W /:
11 :
90713: Review of Periodic and i /:
ROU- :
Special Reports
/ : DRP :
TINE :
/ S:
W /:
11 :
90714:Nonroutine Reporting
/:
ROU- :
Program
'/ : DRS :
TINE :
/ S:
W /:
10
92700: Licensee Event Followup:

/:

YES :
/ : DRP :
NOT TO BE TRACKED :
/ B :
W /:
10 :
92702: Followup - Items of
:/ :
YES :
Noncompliance
/ : ALL : ALL :
NOT TO BE TRACKED :
c:
/ B :
.W /:
10 :
92703:IE Bulletin /Immediate : -/

YES :

Action Letter Followup : / : DRP :
/ B :
.W /:

7 :

i927D4: Followup on HQ Requests:

/:

YES :
(TRACK FOR DRP DNLY)
/ : ALL :
/ S :
W /:

7 :

92705: Followup on Regional
'/ :
YES :
Requests (TRACK FOR
/ : ALL :
3 :
DRP ONLY)
/ S :
~
  1. 1 is May 1986 PAGE 17 Updated to 2515 change'of 09/17/84 Ftcility: DAVIS-BESSE R: vision Date
F /:
RSN : May/: J u l /: Sep/: Nov/: J: n/: Mar /: May/: J ul /: Sep/: Nov/: Jan/: Ma r/:
Mod.:
/:
86/ : /: / :/ :87/ : / :

/:

/:

/ : - / :88/ :

/:

No. :

Description

/ :
/ : / : / : / : / : / : / : / ': / : /.: / : / :
/ P : DIV : SEC : SCH :/Jun:7Aug: /0ct: /Dec: /Feb: /Ap r: /J un: /Aug: /Oct: /Dec: /Feb: /Ap r:
W /:
10 :
92709:Fo110wup on Licensee
/:
7/86 :
Plans for Coping with : / : DRP :
NOT TO BE TRACKED :
Strikes
/B&M:
W /:
10 :

l

92710:Fo110wup on Initial
/:
7/86 :
Implementation of
/ : DRP :
NOT TO BE TRACKED :
Strike Plan
/B&M:
Followup on Continuing : W /:
10 :
92711: licensee (during Imple.:

/:

7/86 :
of strike) Strike Plans: / : DRP :
NOT TO BE TRACKED :
During Extended Strike :/B&M:
W /:
10 :

l

92712:Fo110wup on Resumption :

/:

7/86 :

i

of Normal Operations
/ : DRP :
NOT TO BE TRACKED :
After a Strike
/B&M:
W /:

7 :

92715: Review of Part 21

/:

YES :
Reports
/ : DRP :
/ S:
W /:

7 :

92716:Part 21 Report Followup:

/:

YES :

l

/ : CRP :
/ 5:
W /:

7 :

92717:Fo110wup IE Circular & :

/:

YES :
Info. Type Bulletin
/ : DRP :
/ S:
  1. 1 is May 1986
  • Ecch Inspection PAGE 18 Updated to 2515 change of 09/17/84 Ftcility: DAVIS-BESSE R; vision Date r

J:

F /:
RSN : May/: J ul /: Sep/: Nov/: Jan/: Ma r/: May/: J ul /: Sep/: Nov/: Jan/: Mar /:
Mod.:
/:
86/ : /: /:

/ :87/ : /:

/: /: /:

/ :88/ : /:

No. :

Description

/ :
/ : / : / : / : / : / : / : / : / : / : / : / :
/ P : DIV : SEC : SCH : /J un: /Aug: /Oct: /Dec: /Feb: /Apr: /Jun: /Aug: /Oct: /Dec: /Feb: /Apr:
W /:
10 :
93702:0nsite Followup of

/:

YES :
Events at Operating
/ : DRP :
Reactors
/B&M:
W /:
11 :
94600:Information Meetings
/:
YES :
with Local Officials
/ : DRP :
/ S :
W /:
11 :
94700: Participation in ACRS :

/:

YES :
Meetings
/ : ALL :
/ S :
W /:
11 :
94702: Participation in NRR/ :

/:

YES :
Licensee Meetings
/ : ALL :
/ 5 :
W /:
11 :
94703: Media Contacts

/:

YES :
/ : DRP :
/5 :
  1. 1 is May 1986 PAGE 19 Updated to 2515 change of 09/17/84 Facility: DAVIS-BESSE R: vision Date
  1. 1 /: 3 /: 5 /: 7 /: 9 /:11/:13 /:15 /:17 /:19 /:21/:23 /:
ITEM:

_ : /:

/: /: /: /: /: /: /: /: /:

/: /:

Description

/ : / : / : / : / : / :/ : / : / : / : / : / :
DIV : SEC : SCH :/ 2:/ 4:/ 6:/ 8:/ 10:/ 12:/ 14:/ 16:/ 18:/ 20:/ 22:/ 24:
Open Items; Unresolved :
Prior:
ATTCH: Items and Violations --: ALL : --- :

to :

l' : Region III Tracking

Re- :
System
start:
Course of Action Item :
Prior:
ATTCH:as Result of June 9
ALL : --- :

to :

2 : Event'

Re- :
start:
Performance Enhancement:
Prior:
ATTCH: Programs and SALP IV
DRP : --- :

to :

3 : Response

Re- :
start:
ATTCH: Major Activities
ALL : -- :
ROU :
4 :---Davis-Besse
TINE :
Prior:
ATTCH:NRC Restart Test
DRS : --- :
to/ :

5 : Review Group

during startup :
During
ATTCH: Augmented Inspection
DRP : --- :
Restart 6 :During Restart and
Operation
ROU- :
ATTCH: Course of Action
ALL : --- :
TINE :

7 : Program - Commitments :

ROU- :
ATTCH: Study Group Observa-
ALL : --- :
TINE :

8 :tions and Findings

  1. 1 is May 1986 FAGE 20 Ftcility: DAVIS-BESSE R3 vision Date

REASONS FOR NOT DOING CERTAIN MODULES

1. PAS Reduction:

Modules 41700, 41701, 37700 only.

2. SALP Reduction:

Modules 41700, 41701, 71710, 37700, 82201 through 82206, 8300 series and 8400 series only.

3. Insufficient Manpower.
4. No projected licensee activities in this area.
5. No significant concerns identified in this area.
6. Not applicable to Resident Program.

6a. Module Not Due.

REASON FOR PERFORMING A CERTAIN MODULE

7. Required by MC 2515.
8. Poor SALP Evaluation in this area.
9. Poor licensee performance, inspector / supervisory concern or noncompliances recently identified related to this area.
10. Module is required by minimum / basic program.
11. Module is required by Basic / Supplemental program but limited scope is planned.
12. Anticipated activity.

13.

Module never performed at the facility.

PAGE 21 l

L