Discusses Meeting on 971029 Re SALP Rept 50-416/97-99 Issued on 971009.Meeting Provided Opportunity to Communicate Perspectives for Each SALP Functional Areas & Insights Into Factors Which NRC Considered When Determining SALP Ratings
ML20199C661
Person / Time
Site: Grand Gulf 
Issue date: 11/17/1997
From: Gwynn T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Hagan J
ENTERGY OPERATIONS, INC.
References
50-416-97-99, NUDOCS 9711200083
Download: ML20199C661 (10)


See also: IR 05000416/1997099

Text

--

. - -

-

. - . - ~ - . .- - .

. - . .

.

..-_.- ,- . . - _ _ . _

. .

.

/ "%o

uNiffoSTATES

(

/

,t

NUCLEAR REGULATORY COMMISSION

-

$

. /-

3

RioloN iv

$11 RYAN PLAZA ontvt.sulTE 400

i

' ' '

n

.

ARLINoToN, TE XAS 760118064

" " * *

NOV I 7 997

i

I

Joseph J. Hagan, Vice President

!

Operations Grand Gulf Nuclear Station

Entergy Operations, Inc.

P.O. Box 756

Port Gibson, Mississippi 39150

l

SUBJECT: SYSTEMATIC ASSESSMENT OF LICENSEE PERFORMANCE (SALP) PUBLIC

MEETING (OCTOBER 29,1997)

Dear Mr. Hagan:

i

This refers to the NRC meeting open to public observation conducted on

October 29,1997, at the Grand Gulf Nuclear Station in Port Gibson, Mississippi. This

meeting discussed SALP Report 50 4i6/97 99 which was issued on October 9,1997.

The meeting provided an opportunity for us to communicate our perspectives for each of

the SALP functional areas and our insights into the factors which the NRC considered

when determining the SALP ratings. Attendees at the meeting are listed in Enclosure 1 to

,

'

this letter. Enclosure 2 is a copy of the NRC's presentation slides.

This letter also acknowledges the input provided by Grand Gulf in response to the SALP

report. Your comments addressed both Grand Gulf's and Entergy's perspectives regarding

performance in the different functional areas. The discussions also addressed planned and

in place strategies for improving performance in Plant Support. We look forward to seeing

the results of the Entergy wide initiatives you are planning in the emergency preparednest,

area,

in accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter

will be placed in the NRC's Public Document Room.

Should you have any questions concerning this matter, we will be pleased to discuss them

with you.

.

Sincerely,

'/

'

f 6 4.

)., 4 ~

Thomas P. Gwynn,' Director

Division of Reactor Projects

,

,

Docket No.: 50-416

L! cane.e No.: NPF 29

h h

.-

.

.

.

.

..

--

. - - - - - - .

- .

. - _

_

_ ._-_

_ ~ _ . . _ _ _ _ - . . _ . _ . _ _ _ . . ._ .- _ . _ . - . _

_. _ .. _ ..__ - _ - _ _ -

i

.

j

i

I

!

Entergy Operations, Inc.

. 2-

l

t

i

!

I

1

Enclosures:

1. Partiallist of Attendees-

2. Visual aids from Public SALP meeting

,

i

t

cc w/ enclosures:

I

Executive Vice President -

and Chief Operating Officer -

Entergy Operations, Inc.

P.O. Box 31995

Jackson, Mississippi 39286 1995

,

t

!

+

- Wise, Carter, Child & Caraway

- P.O. Box 651

-

Jackson, Mississippi 39205

-

.Winston & Strawn

^

1400 L Street, N.W.

12th Floor

Washington, D.C.. .20005 3502

l

Sam Mabry, Director

Division of Solid Waste Management

- Mississippi Pepartment of Natural

+

!

Resources

P.O. Box 10385

i

Jackson, Mississippi 39209

l

3

'

President

Claiborne County Board of Supervisors

Port Gibson, Mississippi 39150

Manager of Operations

,

'

Bechtel Power Corporation

P.O. Box 2166

Houston, Texas 77252 2166

.

!

l

General Manager

,

- Grand Gulf Nuclear Statio .

l

,

. Entergy Operatior's, Inc.

P.O ~ Rox 756

- Pet dibson, Mississippi 39150

,

a

?

..w

.w.

,,. .

..

-

.u.._y.

..m.<,,_+

mM,.-

,,,y.

. . . '

,y.

e

,y,

.

m. y7 ,, yy

y,

, , , -

p.m.,..

,,y..,,

, ,,

- . . _ .

,._ [

'

.

__-_____ _ __

_.

'

J

.

3-

s

Entergy Operations, Inc.

-

The Honorable William J. Guste, Jr.

Attorney General

Department of Justice

State of Louisiana

P.O. Box 94005

Baton Rouge, Loulslana 70804 9005

Office of the Governor

State (./ Mississippi

Jackson, Mississippi 39201

Mike Moore, Attorney General

Frank Spencer, Asst. Attorney General

State of Mississippi

P.O. Box 22947

Jackson, Mississippl 39225

Dr. F. E. Thompson, Jr.

State Health Officer

State Board of Health

P.O. Box 1700

Jackson, Mississippi 39205

Robert W. Goff, Director

State Liaison Officer

Division of Radiation Hea!!h

Mississippi Department of Health

P.O. Box 1700

Jackson, Mississippi 39215 1700

Vice President

Operations Support

Entergy Operations, Inc.

P.O. Box 31995

Jackson, Mississippi 39286 1995

Director, Nuclear Safety

and Regulatory Aff airs

Entergy Operations, Inc.

P.O. Box 756

Port Gibson, Mississippi 39150

m-a

--- .. -

p-s

- - -- +

m

.

.

_

_

l

l..

l

Entergy Operations, Inc.

4

-

Vice President, Operations

~

Grand Gulf Nuclear Station

Entergy Operations, Inc.

P.O. Box 750

Port Gibson, Mississippi 39150

,

V

-

,

- -

t

- - -

s--

w

-

w

- ,

-

g

a

_

__-_ __ _ _______-_ _ ______ - -_____ _ _____-_ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ - _ _ _ _ __ _ - _ _

_

l

'

'

l

.

Entergy Operations, Inc.

-4-

l 7 997

,

hec to DCD (IE40)

'

bec distrib. by RIV:

Regional Administrator

C. A. Hackney, RSLO

DRP Director

DRS PSB

Branch Chief (DRP/G)

MIS System

-

!

Project Engineer (DRP/G)

RIV File

Branch Chief (DRP/TSS)

B. Murray, DRS/PSB

!

'

- The Chairman (MS: 16 G 15)

Records Center, INPO

Deputy Regional Administrator

DRP File

-

Commissioner Dieus

B. Henderson, PAO

Commissioner Diaz

Carol G ;rdon

Commissioner McGaffigan

SRis at all RIV sites

L. J. Callan, EDO (MS: 17 G 21)

Associete Dir, for Projects, NRR

Associate Dir. for Insp., and Tech. Assmt, NRR

!

SALP Program Manager RR/lLPB (2 copies)

-

J. Hannon, NRR Project Director, PDIV 1

J. Donohew, NRR Project Manager

t

DOCUMENT NAME: R:\\_GG\\GG1029MS.DRP

To receive copy of document, Indicate in box: "C" = Copy without enclosures "E" = Copy with er'*sures "N" = No copy

RIV: SRI

C:DRP/F

D:DRP

d

JLDixon-Herrity:df -

DFKirsch

TPGwynn /3 //g>

11/7/97 (DFK)

11/7/97 (E)

11/11197/j

OFFICIAL RECORD COPY

._

_

. .

. .

.

.

, _ .

.

. . . . -

,

_ __

_ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ .

__ _ _ _

_ _ _ _ _ _ - _ _ _ _ _ _ _

Entergy Operations, Inc.

-4-

7.g

.

bec to DCD (IE40)

bec distrib. by RIV:

Regional Administrator

C. A. Hackney, RSLO

DRP Director

DRS PSB

Branch Chief (DRP/G)

MIS System

Project Engineer (DRP/G)

RIV File

Branch Chief (DRP/TSS)

B. Murray, DRS/PSB

The Chairman (MS: 16 G 15)

Records Center, INPO

Deputy Regional Administrator

DRP File

Comrnissioner Dieus

B. Henderson, PAO

Commissioner Diaz

Carol Gordon

Commissioner McGaffigan

SRis at all RIV sites

L. J. Caller . EDO (MS: 17 G 21)

Associate Dir. for Projects, NRR

Associate Dir. for Insp., and Tech. Assmt, NPR

SALP Program Manager, NRR/lLPB (2 copies)

J. Hannon, NRR Project Director, PDIV 1

J. Donohew, NRR Project Manager

DOCUMENT NAME: R:\\_GG\\GG1029MS.DRP

To recetv, copy of document, indicate in boa: "C" = Copy without enclosures

E" = Copy with enclosures "N" = No copy

RIV:SFl

' C:DRP/F

D:0RP

l ,.

,

l

JLDixcn Hernty;df

DFKirsch

TPGwynn

,

I

11/7/97 (DFK)

11/7/97 (E)

11/. /97

"

~

OFFIC:AL RECORD COPY

f

ENCLOSURE 1

l

PARTIAL ATTENDANCE LIST

Jennifer L. Dixon Herrity, Senior Resident inspector, NRC

Jack Donohew, Project Manager, NRC

Ellis W. Merschof f, Regional Administrator, NRC

Kenneth E. Brockman, Deputy Director, Division of Reactor Projects, NRC

Kathy D. Weaver,, Resident inspector, NRC

Charles A. Hackney, State Liaison Officer,NRC

Brock W. Henderson, Public Aff airs Officer, NRC

Thornas G. Hiltz, RIV Coordinator, EDO, NRC

Donald C. Hintz, Group President, Chief Nuclear Operations Officer, EOl

Ron Burns, President and Chief Operating Officer, EOl

Jerry W. Yelverton, Executive Vice President, EOl

Joseph J. Hagan, Vice President Operations, Grand Gulf

Danny G. Bost, Director, Design Engineering, GGNS

William A. Eaton, General Manager, Plant Operations, GGNS

Joseph E. Venable, Manager, Operations, GGNS

Ronald V. Moomaw, Manager, Plant Maintenance, GGNS

Charles W. Elisacsser, Manager, Performance and System Engineering, GGNS

Larry F Dale, Director, Plant Projects and Support, GGNS

Curtley C. Hayes, Director, Quality Programs, GGNS

Kenneth Hughey, Director, Nuclear Safety & Regulatory Aff airs, GGNS

Charles E. Smith, Manager, Planning and Scheduling, GGNS

Robert W. Goff, Director, Mississippi Division of Radiation Health

Stella Moore, Claiborne County Civil Defense

William H. Spell, State of Louisiana

Silas Anderson, Mississippi Radiological Health Physics Administration

Marcus Water, Manager of Production, Southwest Mississippi Electric Power Assoc.

Rick Foster, Director, Tensas Parish Emergency Preparedness

Bob Chapman, Mississippi Emergency Management Agency

Stan Shaw, Louisiana Radiation Protection Division

Bobbie Young, Director, Claiborne County Civil Defense

Charlene Moore, Claiborne County Department of Administration

James Grey, Claiborne County Fire Department

,

!

l

l

l

_______

_

___

_

a

4- !. $

L NITED STATES NUCL

!

REGLLATORY COMMIS

,0 ,

-+

C

gREG O

A

6p

l

$

0

,

+m+

x

'

IN3

$ SYSTEMATIC ASSESSMENT OF

./%

LICENSEE PERFORMANCE

i,

< SALP)

'

'

'

p.

4)d/

%'

,

%

GRAND GL LF

N;

v..

~

\\ucument Potiod;

h February 25,1996 through September 6,1997

g-

2

Prewniation

7

j

October 29,1997

h

. . . _ . - . _ - - _ . . _ _ _ - , _ _ _ . - _ - _ - _ , , . . _ _ _ - - _ _ . . _ . . _ _ .

. _ . , _

. . _ _ , _ . . _ . _ , . - - - _ _ . _

'"

]

..

..

SALP PROCESS

' - - > Resident inspector

Program

Region Based

inspecton

REGIONAL

^

SALP

DMINISTRATO

BOARD

-*

""S'"9

Special

Initiatives

->

Event Reviews

_

PPR Process

MIP

<

. .

-.

--

-

-.

-_

-

-

,

i

.

l

GRAND GULF

SALP RATING SUMMARY

,i

j

,

!

4

FUNCTIONAL

RATING

RATING

<

!

AREA

THIS PERIOD

LAST PERIOD

'

OPERATIONS

1

1

MAINTENANCE

1

2

ENGINEERING

1

1

.:

PLANT SUPPORT

2

1

,

i

n

4

r

p

.

.

.

-~-

- .

- . - - . - - - - . - - . - - - - ~ + - - ' - - - - , , -

- - -

-