Requests NRC Approval to Use ASME Code Case N-133-2 for Design & Fabrication of Replacement Valves for Svc Water Sys.Replacement Valve Design More Reliable,Due to Use of Aluminum Bronze Alloy 954 & Monel Alloy 400
ML20199C338
Person / Time
Site: Salem  
Issue date: 06/11/1986
From: Corbin McNeil
Public Service Enterprise Group
To: Varga S
Office of Nuclear Reactor Regulation
References
NLR-N86087, NUDOCS 8606180078
Download: ML20199C338 (2)


Text

e P

Pubhc Service Electric and Gas Company CIrbin A. McNeill, Jr.

Public Service Electnc and Gas Cornpany P.0, Box 236, Hancocks 8ndge NJ 08038 609 339 4800 Vice Pres + dent -

Nuclear June 11, 1986 NLR-N86087 Office of Nuclear Reactor Regulation U.S.

Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, MD 20014 Attention:

Mr. Steven A.

Varga, Director PWR Project Directorate #3 Division of PWR Licensing A

Dear Mr. Varga:

ASME CODE CASE N-133-2 SALEM GENERATING STATION UNIT NOS. 1 AND 2 DOCKET NOS. 50-272 AND 50-311 The purpose of this letter is to request, pursuant to the requirements of 10CFR50.55a(a)(3), that the NRC approve the use of ASME Code Case N-133-2 for use in the design and fabrication of replacement valves for the Salem Units 1 and 2 service water systems.

The replacement valves currently being purchased are Jamesbury Model 815L-ll-14RLMT which utilize alternate bolting material for the four bolts closest to the shaft on either valve face.

The use of alternate bolting material was approved in Code Case N-133-2 and represented the only change from Code Case N-133-1.

The use of Code Case N-133-1 has been approved by the NRC.

The replacement valves are of a more reliable design in that the use of Aluminum Bronze Alloy 954, as approved by Code Case N-133, is more resistant to erosion.

Maintenance of these valves is also easier to accomplish resulting in greater system availability.

The alternate bolting material was fabricated from Monel Alloy 400 utilizing material specification SB-164.

This material combines the mechanical and material properties necessary to assure structural integrity and limit galvanic corrosion.

For these reasons, PSE&G believes that the requirements of 10 CFR 50.55a(a)(3) have been satisfied and that the use of ASME Code Case N-133-2 is acceptable.

8606180078 860611 DR ADOCK 05000 2

l0

p-J Steven A. Varga 6-11-86 Should you have any questions regarding this information, we would be happy to discuss them with you.

An expeditious response to this request would be greatly appreciated.

Sincerely, C

Mr. Donald C.

Fischer Licensing Project Manager Mr. Thomas J.

Kenny Senior Resident Inspector