OM S.S j

y;

.t L

OCT 181985 l

Dayco Corporation.

'P.O. Box.3258

._ 25804.

i Springfield, M0 t

t ji

- Gentlemen.

' As a resultLof the inspection conducted on July 10 to July 24, 1985, a Form NRC-591, SAFETY INSPECTION..is issued for.your NRC general license.. You l

will note that this form indicates that no item of noncompliance was found.

It is not necessary that you acknowledge receipt of this form.

a The enclosed copy of our inspection report identifies areas examined during I

p' gpb i-the inspection.

Within these areas, the inspection consisted of a selective examination of procedures'and representative records, observations, and

- telephone-interviews with your personnel.

4

\\

If you have any questions or require clarification on any of the information

- stated'above', you may. contact us at (312) 790-5616.

-l

-Thank you for your cooperation.

Sincer ly, I

4,/

p

. G. Wiedeman, Chief _

-l Nuclear Materials Safety Section 1

Enclosures:

As stated I

bec w/ enclosures: -

.L. Cobb, 01E

.S.:Baggett, NMSS t

\\

\\

q i@Ol RIII Wiedeman/1d 1

010/16/85

'9901140216 851018 PDR..RC-SSD-PDR

m.

4 GENERAL LICENSE GAUGE DATA COLLECTION FORM I

1.

Name and Address of General Licensee:

Dayco Corporation j

P.O. Box 3258 i

Springfield, M0 25804 (417) 881-7440 2.

Principal Business of Licensee:

Rubber Manufacturer - V. Belts 1

4 3.

Purpose for which gauge (s) are used (e.g., measurement of level, dent,ity, flow, thickness,etc.):

1 Density.and Thickness 4.

Gauge Specifics:

a.

Manufacturer:

Measurex Corporation b.

Model Number:

1202 Measurex System Number 162 c.

Isotope / Activity:

strontium-90/50 millicuries d.

Date Received: May 31, 1974 e.

Date Replaced:

September 29, 1980 5.

Name of specific licensee that installed gauge:

i Measurex Corporation 6.

Does the gauge have a durable, legible and visible label:

Yes 7.

'Was an Initial Radiation Survey performed at time of installation and do they have a record (list results) NOTE:

records only required for 2 year period:

N/A - Past two years since installation.

- 8.

Leak Tests:

a.

Have the tests been performed (list results):

Yes.

No source leakage indicated, removable contamination <.004 pCi.

b.

Name of firm / person conducting test:

Measurex Corporation - Ken Rice o

r

R c.

Are records available of tests (list date of last test):

l NOTE:

records only maintained for 2 years t

l Yes. June 21, 1985; December 19, 1984; June 26, 1984; December 27,

)

1983; and June 28, 1983 9.

Operational Test of Gauge:

1 a.

Have any tests been performed of the on/off mechanism:

Yes. All radiation warning lights, shutters, interlocks were tested and found to be functioning correctly.

i 4

l b.

Name of firm / person who performed test-i i

Measurex Corporation - Ken Rice

]

c.

Are records maintained of tests (list dates):

.]

i Yes. ' June 21, 1985; December 19, 1984; June 26, 1984; December 27, 1983; and June 28, 1983.

10.

Has the gauge been moved from its original location? If so, by whom:

No.

11.

Does the licensee have personnel who are responsible for assuring compliance with the General License Conditions (10 CFR 31, 31.5(c)

..(1.through 10):

Yes, Jim Chipman.

12.

Has the licensee made any transfers of gauges:

No.

' 13.

Name and Address of Gauge Manufacturer:

Measurex Corporation One Results Way Cupertino, CA 95014 14.

Onsite inspection of gauge (s) (list observations / measurements):

N/A 15.- Name of ORAU Reviewer L

,/

[

p 5 : =

.)< a sy A-/7-W j

Date

.2

p

t. -

l

.4 16.

Signature and Date of NRC'Reviqwer 1

l 1p hw pv7-fr

'/

Date 1

6 4

S i

i l

3

._.