_
w T E X A S E N G I N E E llI N G E X P E lll.\\l E N T S TATI O N TEXAS A&M UNIVERSITY COLLEGE STATION. TEXAS 77843 J575 f
f 4
aW i
NUCLEAR SCIENCE CENTER i
January 26,1998 409 845-7551 U.S. Nuclear Regulatory Commission 98-0010 ATTN: Document Control Desk Washington DC 20555 Subiect:
Request for Amendment to Technical Specifications of Facility License R-83
Reference:
- 1. Texas A&M University Nuclear Science Center Reactor License R-83 2.
- 3. Safety Evaluation for the Production oflodine-125 at the Texas A&M University Nuclear Science Center (attached)
Dear Sir:
The Texas A&M University System Nuclear Science Center has signed a proprietary agreement with a company to produce commercial quantities ofIodine-125. The bulk of the isotope used in the United States is currently produced in Canada. The proprietary content of this application is necessary for a complete regulatory review. The sponsoring company has requested that all information regarding the design be treated as confidential and "Need to Know."
It is requested that the Technical Specifications of R-83 be changed to include the following, inserted as paragraph 3.6.2(c):
Each experiment used for the production ofIodine-125 shall be controlled such that the total inventory of Xenon-125 in an individual experiment is n;s greater than 1000 Curies.
/
The value of 1000 Curies is based on a safety analysis performed at the Nuclear Science Center that calculated exposures to the public to be less than 0.5 rem per year (10 CFR 20.1301) from an accident. The value of 1000 Curies gives a comfortable margin of
/
,g safety and would result in an Emergency Action Level that requires Alert classification.
^
The 1000 Curies of Xenon-125 reduces the inventory ofIodine -125 available to approximately 10 Curies per experiment.
f a rg) hN PDk (
l
\\
qng' '\\\\\\\\f' '\\
Ys
,, y )t Y l
RESfARCH AND DE'MLOPMENT FOR MANKIND 9801290068 980126 PDR ADOCK 05000128 P
98-0010 Page 2 -
The facility Emergency Plan is being updated to include responses to an accidental release of Xenon-125 and the implementing procedures will be approved at a scheduled Reactor Safety Board meeting in mid-February.-
Please contact me if you have any questions or concerns, i
Sincerel,
/
Sean O' Kelly Assistant Director SOK/tl
Attachment:
(1) Safety Evaluation xc:
Theodore S. Michaels NRR/DRPM/PDND 12110/ Central File.
e