_ _..
A M SS l
/
OCT 2 e 1985 Consolidated Aluminum Corporation P.O. Box 164 Hannibal, OH 43931 Gentlemen:
As a result of the inspection conducted on August 22 and 23, 1985, a Form NRC-591, SAFETY INSPECTION, is issued for your NRC general license.
The enclosed form j
sets forth the item of noncompliance noted.
Please acknowledge receipt of di this form by signing and dating in the appropriate space on all copies.
You o'>
are requested to retain the original and return four signed and dated copies to this office within ten days.
J The enclosed copy of our inspection report identifies areas examined during the inspection. Within these areas, the inspection consisted of a selective examination of procedures and representative records, observations, and telephone interviews with your personnel.
If you have any questions or require clarification on any of the information stated above, you may contact us at (312) 790-5616.
Thank you for your cooperation.
Sincerely, j
D. G. Wiedeman, Chief Nuclear Materials Safety 4
Section 1
\\
1
\\
Enclosure:
As stated i
bec w/ encl:
a; L. Cobb, 01E t'
S. Baggett, NMSS g>
l l
RIII
/
t Wiedeman/pg 9901140065 851029 10/23/85 PDR RC SSD PDR
=. _ -.
GENERAL LICENSE GAUGE DATA COLLECTION FORM 1.
Name and Address of General Licensee:
Consolidated Aluminum Corporation P.O. Box 164 Hannibal, OH 43931 (614)483-1341 2.
Principal Business of Licensee:
Aluminum Rolling
]
3.
Purpose for which gauge (s) are used (e.g., measurement of level, density, flow, thickness,etc.):
Thickness j
4.
Gauge Specifics:
a.
Manufacturer:
Accuray Corporation b.
Model Number:
U-6 No. 083329413 c.
Isotope / Activity:
Strontium-90/70 millicuries, SN 1170T d.
Date Received:
December 1980 l
e.
Date Replaced:
N/A 5.
Name of specific licensee that installed gauge:
Accuray Corporation 6.
Does the gauge have a durable, legible and visible label:
Yes 7.
Was an Initial Radiation Survey performed at time of installation and do they have a record (list results) NOTE:
records only required for 2 year period:
N/A Past two years since installation.
8.
Leak Tests:
a.
Have the tests been performed (list results):
l Yes, Negative b.
Name of firm / person conducting test:
Accuray Corporation /D. Higgs J
i c.
Are records available of tests (list date of last test):
NOTE:
records only maintained for 2 years Yes.
July 16, 1985*; January 31, 1985; July 15, 1984*;
January 20, 1984
- No records, dates obtained from Accuray Corporation 9.
Operational Test of Gauge:
a.
Have any tests been performed of the on/off mechanism:
Yes. Shutter-0K b.
Name of firm / person who performed test:
)
Accuray Corporation /D. Higgs i
c.
Are records maintained of tests (list dates):
July 16, 1985*; January 31, 1985; July 15, 1984*; January 10, 1984
- No records, dates obtained from Accuray Corporation.
10.
Has the gauge been moved from it's original location? If so, by whom:
No.
11.
Does the licensee have personnel who are responsible for assuring compliance with the General License Conditions (10 CFR 31, 31.5(c)
(1 through 10):
Richard W. Libby 12.
Has the licensee made any transfers of gauges:
No 13.
Name and Address of Gauge Manufacturer:
Accuray Corporation 650 Ackerman Road P.O. Box 022 Columbus, OH 43202 14.
Onsite inspection of gauge (s) (list observations / measurements):
N/A 15.
Name of ORAU Reviewer
..J ab hwg p-@ W Ri' chard C. Rookard Date 2
l i
l P
)
16.
Signature and Date of NRC Reviewer l
e Y A k ^^ = %
p *2/~/f l
D.
G~. Wiedenian Date 1
l l
I i
i 6
i i
i I
I l~
3
I 5AF L i Y INSPEGlION l
- t. LICE NSE E
- 2. f4E GION A L OF FICE U.S. NUCLEAR REGULATORY C0!HISSION Consolidated Aluminum Corporation.
REGION 111 P
- 0. Box 164 Hannibal, OH 43931 799 ROOSEVELT ROAD GLEN ELLYN, IL 60137
- 3. DOCK ET NUMBER (S)
- 4. LICENSE NUMBEM(S)
- 6. DAT E OF INSPECTION 99990003 General August 23, 1985 Licensee:
The inspection was en enemination of the activities conducted,under your license es they relate to radiation esfety and to compliance with the Nuclear Regulatory Commissiord (NRC) rules and regulations and the conditions of your lioones. The inspection cons'wted of selectiw eneminations of procedures end representative records, interviews, with personnel, and obserwtions by the inspector. The findings es a result of this inspection are as follows:
] 1. Within ene scop. of this inspection, no violetions were observed.
] 2. The inspector also verified the steps you have taken to correct the violations iderdified during'the test inspection. We hows no further questions on those actions et this time.
] 3. During this inspection certain of your actMties, as checked below, were in vlotetton of NRC requiremems.
THD IS A NOTICE OF VIOLATION which is required to be posted in ogcordenos with 10 CFR 19.11.
A.
won w property posted to indicate the presence Cfe
.10 CFR 20.203(b), (c), (d), (e) or 34.42.
B.Conteiners lomted in were not property labeled to indiate the presence of radioectiw meterial.10 CFR 20.203(f)(1), or (f)(2).
C.
of oosted sources were not performed et the proper f roguencies. 10 CF R Lic.n Condition Number D. Records of were not property maintained.
10 CFR or License Condition Number E. Documents were nct properly posted or otherwise snede evellable.10 CFR 19.11.
F. Reports or notifications of were not made in accordsoce with 10 CFR or License Condition Number X H. Records of leak f acts and shutter tottc ; fnr tacte ennAnttod nn.1nl u 1si, loga 3na Juiy 16.1985, were not maintained.
10 CFR 31.5 (C)(4) n.
J.
K f
A i w.reev.tst. twet wtthin so aev. in..etson, o crin.e ey m. to in. in.p.cier wm rr.ct, vioietio so.ritivi.
.n the si.m. en.ca.o edo.
ina es:3.m.ni of corr.cti...etion. i. m.a. in.ccoro.nc. witn th. r.ouir.m.ni..,e. t.k.a to CF 2.
- t. N e n.,,
on.. we euemits.a uni. r.ouir.a av tw. N *.C.
s 7
54GNATURE - LICENSEE DATE E6GNATURE - NRC INSPECTOR
/ D A"r E ORIGINAL TO LICENSEE
-.. ~ - -.
-