Forwards Safety Insp Conducted on 850805-06 for NRC General Licensed Issued to Choc-ola Bottlers.No Items of Noncompliance Found
ML20199B553
Person / Time
Issue date: 10/18/1985
From: Wiedeman D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
AFFILIATION NOT ASSIGNED
Shared Package
ML20199B557 List:
References
SSD, NUDOCS 9901130368
Download: ML20199B553 (4)


Text

.

,l I

A MEE

  • 5 00T 18 BBS Choc-ola Bottlers

.p 2301 Churchman Avenue

-Indianapolis, IN 46203

' Gentlemen:

4 As a result of the inspection conducted on August 5 and 6, 1985, a Form NRC-591, SAFETY INSPECTION, is. issued for your NRC general license.

You will note that this form indicates that no item of noncompliance was found.

It is not necessary that you acknowledge receipt of this form.

The enclosed copy of our inspection report identifies areas examined during

-the inspection. Within these areas, the inspection consisted of a selective examination of procedures and representative records, obsery!!tionb and telephone interviews with your personnel.

If you have any questions or require clarification on any of the information stated above, you may contact us at (312) 790-5616.

Thank you for your cooperation.

Siacere y, A

P O

D.

. Wiedeman, Chief Nuclear Materials Safety Section 1

Enclosures:

As stated bec w/ enclosures:

L. Cobb', OIE S. Baggett, NMSS

\\z

'O9 9901130368 851018 h

PDR 1o $'$1 J

RIII

.Wiedeman/1d 10/16/85

"=

k E

t "4

(-

GENERAL LICENSE GAUGE DATA COLLECTION FORM s

1.

N'ame and Address _of General Licensee:

Choc-ola Bottlers 2301 Churchman Avenue Indianapolis, IN 46203 4-(317)-787-7261 2.

_ Principal Business of Licensee:

I

-Manufacture of chocolate soft drinks.

-3.

Purpose for which gauge (s) are 'used (e.g., measurement of level, density, flow, thickness,etc.):

Unknown.

4.

Gauge Specifics:

1 gauge a.

Nanufacturer:

Accuray Corporation

((,

b.

Model Number:

Flir-201 r7"9 j c.

Isotope / Activity:

cesium-137/14 millicuries

/

d.

Date Receivea:

Unknown

(

e.

.Date Replaced:

N/A

%J/s i

5.

Name-of specific licensee that installed gauge:

~ Unknown.

1 6.

Does the gauge have a durab,le, legible and visible label:

N/A 7.

Was an Initial Radiation Survey performed at time of installation and

-do they have a record (list results) NOTE:

records only required for 2 year period:

1

~

N/A-8.

. Leak Tests:

a.

.Have the. tests been performed (list results):

[

N/A

. b.

Name of' firm / person conducting test:

N/A

_+

a i

t<

m

=.. - -

[\\['.

?t_:)

C. if c.

Are records available of tests-(list date of last test):

NOTE:. records only maintained for 2 years I'

.N/A- ~i c

' 9. '. Operational Test of Gauge:

}

- a.

Have'any tests ~been performed of the on/off mechanism:

N/A g

i b.-

Name of: firm / person who performed test:

N/A c.

Are records. maintained of tests (list dates):

N/A 10.

Has the gauge been moved from it's original loca+, ion? If so, by whom:

i.

Gauge returned to Accuray on December 29, 1975.

o Does-the licensee have personnel who are responsible for assuring) 1 11.

compliance with the General License Conditions (10 CFR 31, 31.5(c e

(1 through 10):

The Indianapolis Choc-ola works shut down in the spring of 1984 and the business was sold about May of 1985.

12.. Has the licensee made any transfers of gauges:

Flir-201 cesium-137/14 millicuries was returned to Accuray Corporation December 29, 1975.

13.- Name and Address of Gauge Manufacturer:

Accuray Corporation

' P.O. Box.02248

-650 Ackerman Road Columbus..0hio 43202

14..Onsite inspection of gauge (s) (list observations / measurements):

Notes:. 'Choc-ola works in Indianapolis stopped operating in the spring of 1984. The building and eauipment was sold about May 1985 to:

Chocolate Group Yoo-Hoo Pat Ferro Carlstad, NJ 4