l,;
),
NM U 13
,y 00T 2 4198(
Sherwin Williams Company 11541 South Champlain Avenue Chicago, Illinois 60628
]
Gentlemen:
As a result of the inspection conducted on August 19, 1985, a Form NRC-591, SAFETY INSPECTION, is issued for your NRC general license.
You will note
/dh that this form indicates that no item of noncompliance was found.
It is not necessary that you acknowledge receipt of this form.
The enclosed copy of our inspection report identifies areas examined during the inspection.
Within these areas, the inspection consisted of a selective examination of procedures and representative records, observations, and telephone interviews with your personnel.
^
If you have any questions or require clarification on any of the information stated above, you may contact us at (312) 790-5616.
Thank you for your cooperation.
~~
/
- n
.d.Wiedeman, Chief Nuclear Materials Safety Section 1
Enclosures:
As stated bec w/ enclosures:
L. Cobb, 0IE S. Baggett, NMSS
\\(\\
q h' DY l
RIII 9901130337 851024 i
PDR RC SSD PDR Wiedeman/ld 10/22/85 l
_ _ _ ___ _ ~._._.___ _
,'f
}
l2 GENERAL LICENSE GAUGE DATA COLLECTION FORM l
L
-1.
Name and Address of General Licensee:
L l
Sherwin Williams Company l
.11541 South Champlain Avenue Chicago, Illinois 60628 l
(312) S21-3137 The gauge is' owned by:
PMC Specialties 735 East 115 Street Chicego, Illinois 60628 (312) 660-4039 l
l 2.
Principal Business of Licensee:
Chemical Manufacture l
- 3.
Purpose for which gauge (s) are used (e.g., measurement of level, density, flow, thickness,etc.):
l Flow Control and Density Control.
j 4.
Gauge Specifics:
Two gauges l
l a.
Manufacturer:
Kay-Ray Incorporated b.
Model Number:
3600 (7062-P) sources c..
Isotope / Activity:
cesium-137/100 mil 11 curies for both d.
Date Received:
May 1,-1980 and September 1, 1979 j
e.
Date Removed:
July 1, 1985
. 5.
Name of specific licensee that installed gauge:
Kay-Ray Incorporated 6.
Does the gauge have a durable, legible and visible label:
Yes, labels intact and legible.
i 7..
Was an Initial Radiation Survey performed at time of installation and j'
do they have a record (list results) NOTE:
records only required for 2 l.
year period:
Yes, Kay-Ray, Incorporated surveyed with assistance from Sherwin Williams instrument technicians.
e a
f-i l
I
8.
Leak Tests:
a.
Have the tests been performed (list results):
l Yes, swipes are sent to University of Cincinnati Radiation Safety l
Office.
Results for past two years indicate no evidence of leakage.
l b.
Name of firm / person conducting test:
Harry Ooms, Radiation Safety Officer takes the swipes and sends them l
to the University of Cincinnati.
He took an Ohmart training course on how to take swipes, etc.
Specific License No. 12-02542-03.
i c.
Are records available of tests (list date of last test):
NOTE:
records only maintained for 2 years Yes, February 15, 1985.
l 9.
Operational Test of Gauge:
a.
Have any tests been performed of the on/off mechanism:
Yes, shutters working properly.
Shutters are always closed during testing or during periods of shutdown or changeover.
1 b.
Name of firm / person who performed test:
Harry Ooms, Radiation Safety Officer.
c.
Are records maintained of tests (list dates):
Yes, Feb,uary 15, 1985; August 28, 1984; February 21, 1984; and August 29, 1983.
Harry was preparing to do August 1985 tests when inspection was initiated on August 19, 1985.
10.
Has the gauge been moved from it's original location?
If so, by whom:
l Yes, one gauge was moved from Vessel 24E to the Paracresol line on May 10, 1983 under Amendment 06 with Kay-Ray supervision and Sherwin Williams instrument technicians.
11.
Does the licensee have personnel who are responsible for assuring compliance with the General License Conditions (10 CFR 31, 31.5(c)
(1 through 10):
Albert Cox was Safety Officer for Sherwin Williams until his retirement.
Harry Ooms became Safety Officer while the company still had the name l
Sherwin Williams.
He continued to be Safety Officer after the name of the company was changed to PMC Specialties on July 1,1985.
l l
l 2
l
1 12.
Has the licensee made any transfers of gauges:
Yes, Sherwin Williams transferred the two gauges surveyed to PMC Specialties, 735 East 115 Street, Chicago, Illinois 60628. The gauges remain in place and are being used for the same purposes as when owned by Sherwin Williams.
Date of transfer July 1,1985.
i 13.
Name and Address of Gauge Manufacturer:
Kay-Ray, Incorporated 516 West Campus Drive Arlington Heights, IL 60004 14.
Onsite inspection of gauge (s) (list observations / measurements):
Notes:
Six month testing schedule in place. There was a few days variation to the strict six months testing rule.
Tests are done in February and August of each year.
15.
Name of ORAU Reviewer lK=u l<wy p-A s-fr
/
Date 16.
Signature and Date of NRC Reviewer
)
p& -..
ras-ff Date l
l l-i l: