OCT 2 8 2 Olin Corporation -
427 North Shamrock Street East Alton, IL 62024 Gentlemen:
As a result of the inspection conducted on September 6 to September 13, 1985, a Form NRC-591, SAFETY INSPECTION, is issued for your NRC general ~ license.
3
-b You will note that this form indicates that no item of noncompliance was
(;
found.
It is not necessary that you acknowledge receipt of this form.
('
The enclosed copy of our inspection report identifies areas examined during the inspection. Within these areas, the inspection consisted of a selective examination of procedures and representative records, observations, and telephone interviews with your personnel.
If you have any questions or require clarification on any of the information stated above, you may contact us at (312) 790-5616.
Thank you for your cooperation.
/
)
Sincere y,
~
./
a D. G. Wiedeman, Chief Nuclear Materials Safety Section 1
Enclosures:
As stated bec w/ enclosures:
L. Cobb, DIE S. Baggett, NMSS-t 9901130332 851028 PDR RC SSD PDR
)
.)
,f kk RIII /
t 1300,he Wiedeman/1d 10/24/85:
.m
s
!{%
9 GENERAL LICENSE GAUGE DATA COLLECTION FORM 1.
Name and Address of~ General Licensee:
Olin Corporation 427 North Shamrock Street East Alton,-IL 62024
.(618) 258-2000
- 2..
Prircipal Buiness of Licensee:
N/A.
3.
Purpose for which gauge (s) are used (e.g., measurement of level, density, flow, thickness, etc.):
Thickness 4.
Gauge Specifics:
1 gauge a.
Manufacturer:
Accuray Corporation b.
Model Number:
U-3 c.
Isotope / Activity:
strontium-90/800 millicuries d.
Date Received:
June 1973 e.
Date Replaced:
January 14, 1974 5.
Name of specific licensee that installed gauge:
-Accuray Corporation 6.
Does the gauge have a durable, legible and visible label:
N/A.
7.
Was an Initial Radiation Survey performed at time of installation and do they have a record (list results) NOTE:
records only required for 2 year period:
N/A.
8.
Leak Tests:
a.
Have the tests been performed (list results):
N/A.
. b.
Name of firm / person conducting test:
N/A.
1
s j
.c.
'Are records.available of tests (list date of last test):
)
NOTE:
records only maintained for 2 years-N/A.
9.
Operational Test of Gauge:
a.
Have any tests been performed of the on/off mechanism:
N/A.
b.
Name of firm / person who performed test:
N/A.
1 c.
Are records maintained of tests (list dates):
N/A.
10.
Has the gauge been moved from it's original location? If so, by whom:
5 Yes, Accuray Corporation.
11.
Does the licensee have personnel who are responsible for assuring compliance with the General License Conditions (10 CFR 31, 31.5(c)
(1 through 10):
Ray Robinson, Radiation Officer 12.
Has the licensee made any transfers of gauges:
Yes.
Accuray Corporation took the gauge back on January 14, 1974.
13.
Name and Address of Gauge Manufacturer:
Accuray Corporation P.O. Box 02248 650 Ackerman Road Columbus, Ohio 43202 14.
Onsite inspection of gauge (s) (list observations / measurements):
Olin Corporation used this gauge for about seven months on a trial basis.
After this trial period they decided to let Accuray Corporation take it back.
Olin is currently using seven LFE Corporation gauges, americium-241/
1000 millicuries. Olin Corporation does its own swipes on these gauges and sends them out.
2
- g..
15.
Name of ORAU Reviewer a...
l
~ku-04#f
/d/3f f
'/
Date '
16.
Signature and Date of NRC eviewer k-p.zr-fr
'/
Date l
1 I
-.u.,
i 3
-