h, OJp Q;
Pbrtlimd W Becide Coiripery 4y N",
/;,M
~'
Ebrt D. Wens Vce Presdort Q
f4 June 6, 1986 Trojan Nuclear Plant Docket 50-344 License NPF-1 Mr. John B. Martin Regional Administrator, Region V U.S. Nuclear Regulatory Comission 1450 Maria Lane, Suite 210 Walnut Creek CA 94596-5368
Dear Mr. Martin:
Steam Generator Tube Plugzing Report During the 1986 refueling outage, eddy current inspections of the steam generator tubes were conducted.
In accordance with Technical Specifica-tion 4.4.5.5.a. attached is a listing of the number of tubes plugged in each steam generator and the reason for the plugging. A total of 42 tubes were plugged, 36 of which were Row 2 tubes which had indications in the l
U-bend region.
Sincerely, Bart D. Withers Vice President Nuclear Attachment c:
Mr. Lynn Frank, Director State of Oregon Department of Energy 8606170044 860606 l
PDR ADOCK 0500 4
1 1
IE6I-a s w sxrren street. Pomand. Oregon 972N