ML20199A827

From kanterella
Jump to navigation Jump to search
Forwards,For Review & Action,Draft Proposed Info Notice Re Incorrect FSAR Designation of GDC 55 & 56 as Not Applicable to Transversing in-core Probe Sys Lines.Condition Described in Encl Generically Important to Nuclear Safety.W/O Encl
ML20199A827
Person / Time
Site: Duane Arnold 
Issue date: 05/08/1986
From: Norelius C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Jordan E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
NUDOCS 8606160042
Download: ML20199A827 (1)


Text

r M

MAY 081986 MEMORANDUM FOR:

Edward L. Jordan, Director, Division of Emergency Preparedness and Engineering Response, IE FROM:

Charles E. Norelius, Director, Division of Reactor Projects Region III

SUBJECT:

INCORRECT FINAL SAFETY ANALYSIS REPORT (FSAR) DESIGNATION OFTRANSVERSINGINCOP.EPROBE(TIP) LINES The attached draft of a proposed NRC Information Notice is transmitted to you for your review and action.

We believe that the condition described in the attached draft is generically important to nuclear safety in that it demonstrates that the TIP system lines were incorrectly designated in the FSAR as lines for which 10 CFR 50, Appendix A, General Design Criteria (GDC) 55 and 56 were not directly applicable.

During a prereview of a recent replacement of an isolation ball valve (see Figure 1) in the TIP system at Duane Arnold, the Operations Review Committee concluded that the FSAR designation of GDC 55 and 56 as being not applicable to the TIP system lines was incorrect. There exists a path through a pressure relief valve (on the indexing mechanism housing) by which containment atmosphere could enter the TIP system if the primary containment became pressurized.

For further information, please contact D. Boyd (FTS 388-5546) of my staff.

Trish:1 Re d L.y CJ. thrciW u

Charles E. Norelius, Director Division of Reactor Projects

Attachment:

Draft of Proposed l

NRC Infonnation Notice cc w/ attachment:

J. S. Wiebe, SRI l

Duane Arnold

{

PDR ADOCK 05000331 l ]l [ fO 860616o042 86050s G

PDR h

/bb RIII RIII RIII Schweibinz/pd Boyd s

05/U3/86 05/ /86 05/3/86 3 ol

' 9

.