j NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20056-4001 gb November 5, 1997 w*
MEMORANDUM FOR: Thomas H. Essig, Acting Chief Generic Issues and Environmental Projects Branch Division of Reactor Program Management Office of Nuclear Reactor Regulation I0
\\
FROM:
Claudia M. Craig, Senior Project Manage Q
g
- 'J* g Generic issues and Environmental Projects ranc Division of Reactor Program Management
(
Office of Nuclear Reactor Regulation
SUBJECT:
SUMMARY
OF MEETING WITH THE WESTINGHOUSE OWNERS GROUP (WOG) TO DISCUSS THE WOG'S COMMENTS ON THE DRAFT SUPPLEMENT TO BULLETIN 96-01 The subject meeting was held at the NRC offices in Rockville, Maryland on October 3,1997, between representatives of the WOG, West.1ghouse, and the NRC staff. The purpose of the meeting was to discuss the WOG proposed process for resolving the incomplete rod insertion (IRl) issue. Attachment 1 is a list of meeting participants. In preparation for the meeting, the WOG provided, by fax, a letter dated October 1,1997, which provided a description of the proposed process to be discussed at the meeting. This letter is provided as Attachment 2. By letter dated October 20,1997, the WOG provided a revised version of the WOG position paper and a proprietary summary of additional drag test data from 1997. Attachment 3 is a copy of the non-proprietary WOG position paper. Attachment 4 is a copy of the non-proprietary
- presentation material.
The meeting consisted of a history of the issue, resu'ts from data, actions taken to date, a summary of the GROWBOW mechanical model, a summary of the WOG com,nents on the draft supplement to Bulletin 96-01, and a detailed description of the WOG proposal. The WOG proposed process consists of: an evaluation of proposed burn-up limits, an evaluation of drag work using ths GROWBOW model, an evaluation of shutdown margin, performing rod drop tests, and collection and analysis of rod drop and drag tests. The WOG believes this process has conservatism built into each step, puts into place a mechanism that will demonstrate control
,4 rod insertability, and provides for long term resolution of the IRI issue. The WOG stated that
/
more than half of the Westinghouse plants agree in general with the proposal, and given more time, more may agree. However, there may be a few plants that have plant-specific data that would not agree with the limits set forth in the proposal.
$l The staff stated the~ process appeared reasonable, however, it had several comments and questions that needed to be addressed, either by the NRC or the WOG. These questions include: whether the burn-up limit is appropriate, whether tha shutdown margin assumptions are appropriate, whether the GROWBOW model is sufficiently conservative, what actions are taken following a trip, and what additional actions will be part of the evduation of shutdown "N""2" l.lill I.ll lllil!.lil.l!.I WF MCHU:CBHECOPY 7 r=e =g
('ry. gqq
,m um,,ma
.E.
2.-
November 5, 1997 T. Essig The staff stated that it would like to finalize a supplement to the Bulletin in the near future. Tne WOG stated that it would like to formalize the WOG proposal and officially submit it to the staff for consideration (the October 20,1997 letter). The staff and WOG agreed that the meeting
_was useful and helpful and that a dialogue should continue.
Project No. 694 Attachments: As stated cc w/atts: See next page y-c
T. Essig
-2.-
November 5, 1997 The staff stated that tl would like to finalize a supplement to the Bulletin in the near future. The WOG stated that it would like to formalize the WOG proposal and officially submit it to the staff for consideration (the October 20,1997 letter).- The staff and WOG agreed that the meeting was useful and helpful and that a dialogue should continue.
Project No. 694 Attachments: As stated' cc w/atts: See next page DISTRIBUTION:
See attached page DOCUMENT NAME: 10_3_97. MIN w@)
BC:SbB,
OFFICE PGEB SC:PGEB NAME CCraid:bb MCa[
TCollins b DATE l} /k /97 4 / ( /97
// / / /97 OFFICIAL RECORD COPY
q 1
.j m
DISTRIBUTION: w/attsi_ Summary of October 3,1997, meeting with WOG dated -
1997 Novemb.er 5
-s-Hard.Copyi OsamfMes
~..
- /
' PUBLIC =
Project File _ -
PGEB R/F
~
s MCase.
' # 'i
_,, CCraig t
- E-Mail:=
SCollins/FMiraglia c
, RZimmerman i
BSheron.
" ' j) Roe 1 cI:
- GHolahan
~
. TCollins -
i t
Y -, MChatterton -
j-AMcKeigney
-J
- FGrubelich
- l
.f HScott HConrad:
4 i
EWeiss HOmstein i
i
+
- ~. - - -
v--
- i.*
WOG/NRC MEETING OCTOBER 3,1997-MEETING PARTICIPANTS
_t Name.
Orgarsidion Claudia Craig
' NRC/NRR/PGEB Eric Weiss NRC/NRR/SRXB Margaret Chatterton NRC/NRR/SRXB Francis T. Grubelich NRC/NRR/EMEB H.F. Conrad NRC/NRR/EMCB -
H.H. Scott -
NRC/RES.
John ~J. Kelly New York Power Authority John Butler NEl William A. Allen American Electric Power Alex McKeigney NRC/NRR/PGEB Hank Sepp Westinghouse -
Dan Redden Comed 1
Carl Snyder NUS-Jim D. Seawright TU Electric
= John Galembush Westinghouse Ken Vavrek Westinghouse Jeb DeLoach Seabrook Station Rick Stemer Northeast Utilities Mike Schoppman Florida Power & Light Co.
Richard Clark Duke Energy Tom Brookmire Virginia Power Jack Bailey TVA/WOG EAC Tom Greene Southem Nuclear /WOG Scott Ferguson Wolf Creek Lynn Connor DSA Bob Borsum FTl Vinny Esposito Westinghouse-CNFD Tim Collins NRC/NRR/SRXB 1
ATTACHMENT 1 -
L
.