ML20199A298

From kanterella
Jump to navigation Jump to search

Forwards Request for Addl Info Re Review of Westinghouse Test Reactor Decommissioning Plan Submitted by . Response to Encl RAI Should Be Submitted within 60 Days of Ltr Date
ML20199A298
Person / Time
Site: Waltz Mill
Issue date: 01/21/1998
From: Michaels T
NRC (Affiliation Not Assigned)
To: Nardi A
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
References
TAC-M99403, NUDOCS 9801270172
Download: ML20199A298 (5)


Text

_

,c J:nuary 21, 1998 i Mri A. J. Nordi-NES License' Administrator.

Nuclear Energy Systems =

i

- Westinghouse Electric Corporation 7

P.O. Box 355.

e Pittsburgh, Pennsylvania 152'30 5

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (TAC NO. M99403)

Dear Mr. Nardi:

We are continuing our review of the Westinghouse Test Reactor Decommissioning Plan submitted by letter July 31,1907. During our review, questions have arisen for which we require additionalinformation;and clarification. Please provide responses to the enclosed request for additionalinformation within 60 days of the date of this letter, in accorr'ince

.with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. This request affects nine or fewer respondents and therefore, is not subject to Office of Management and Budget review under Public Law 96-511. Following receipt of the adod!onalinformation, we will continue our evaluation of your application, if you have any questions regarding this review, please contact me at (301) 4151102.

Sincerely, ORIGINAL SIGNED BY:

Theodore S. Michaels, Senior Project Manager Non Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management

)

Office of Nuclear Reactor Regulation I

cc: See next page DISTRIBUTION:

E-Mall HARD COPY TBurdick TDragoun Docket File 50-22 JRoe PDoyle MMendonca PUBLIC S W els:

- CBassett -

WEreslan -

EHylton PDND r/f AAdams SHolmes TMichaels OGC Pisaac h

PDND:PM g

PD, PDN :D

.1/24/9 8

' ' ' W

'8 TMichael U

E n

SWeiss 1 % /98 1/k/98

" OFFICIAL RECORD COPY DOCUMENT NAME: ' A:\\RAl99403.

E:

k o h 22 P

W' PDR

,pm neau

(

g t

UNITED STATES

}

NUCLEAR REGULATORY COMMISSION f

WASHINGTON. D.C. 30eeHool-

+o January 21, 1998 Mr. A. J. Nardi NES License Administrator tjuclear Energy Systems Westinghouse Electric Corporation P.O. Box 355 Pittsburgh, Pennsylvania 15230

SUBJECT:

REQUEST FOR ADDITIONAL INFL.

ATsON (TAC NO. M99403)

Dear Mr. Nardi:

We are continuing our review of the Westinghouse Test Reactor Decommissioning Plan.

. submitted by letter July 31,1997. During our review, questions have arisen for which we require additionalinformation and clarification. Please provide responses to the enclosed request for additionalinformation within 60 days of the date of this letter. In accordance with 10 CFR 50.30(b), your response must be executed in a signed original under oath or affirmation. This request affects nine or fewer respondents and therefore,is not subject to Office of Management and Budget review under Public Law 96 511. Following receipt of the additionalinformation, we will continue our evaluation of your application.

If you have any questions regarding this review, please contact me at (301) 4151102.

Sincerely, Theodore S. Michaels, Senior Project Manager Non-Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket No. 50-22 cc: See next page

p,.

- 9

^: 1 I

i.;,-

L Westinghouse / Waltz Mill -

Docket No. 50-22 cc:

Mr. James G. Yusko Pennsylvania Department of -

Environmental Protection' 400 Waterfront Drive Pittsburgh, Pennsylvania 15222 h.

u LL

._g-(

)

d-

' f'-'

- _ ~,,... - -

. - ~....

- =_

~

  • y ENCLOSURE-

- i REQUEST FOR ADDITIONAL INFORMATION WESTINGHOUSE TEST REACTOR DOChET NO. 50 22 Please provide the following additionalinformation on the Westinghouse Test Reactor (WTR) Decommissioning Plan (DP).

1. - Provide an operational history of the WTR, including allinformation that could affect planning and safety for decommissioning activities and from which radiological.

Information can be derived. We have reviewed the Characterization Report dated February 1994,'and the report on the WTR Fuel Element Failure of April 3,1960, dated July 7,1960.

t 2.

Provide a discussion concerning routine events and accidental spills or releases of radioactive material that significantly contributed to contamination levels within or near the facility.

3. ' Provide an environmental report (ER), either as a separate report or as a section of the DP. This report is needed to provide the basis for an environmental assessment of the proposed decommissioning action by the NRC, as required by 10 CFR 51.21. To the extent possible, the content of the ER should follow 10 CFR 51.45. The ER should address the following:

~

- the collective dose equivalent to workers for the entire dismantling and decomm!ssioning project.

. potential exposures of the public, including the _most exposed person, from radioactive affluents released during the decommissioning activities and radioactive waste shipments.

anticipated potential exposures of the public after license termination.

4.

Provide a detailed discussion of the soil and groundwater issues identified as "first

' priority" in Reference 2, a Westinghouse letter (dated Nov. 27, 1996) from A.J. Nardi

. to USNRC,' Region I.

~

5. _. Provide a more complete design _ description of the high-efficiency particulate air (HEPA) liltration/ ventilation system (see p. 2 3).

_6.

What is the source of the water in the east test loop dump tank pit (see p. 2-24)?

7.

Provide'a description of the water processing system to be used for treating water in the test loop ~ pits (see p. 2 24).

+

w c

e--

.r.-

+ +

. + -

4

_.\\

2

\\

8.

Although the HEPA filters in the ventilation system were not telled on for the accident--

analyses described in the DP, their operability is assumed during decommissioning

- 1 activities within the WTR containment.. Please commit to providing an appropriate i

program for testing the efficiency of these filters, both at the time of installation and periodically during the course of the decommissioning effort. Surveillance requirements for this program should be included in the Technical and Environmental Specifications for WTR" during the decommissioning phase.

f a

a a

'on a.

-m.

P

-e.

ry.

w.