Text
%
O/70oscao Fyops 1
Atlaat* N w& Heahadas ANAC -
P 655 Engineering Drive INTERNATIONAL Nwcross, Ccwp 30092 770-447 1144 Fax 770-4471797 -
www nacintl.com December 5,1997.
[ p g6 '[2-l
-:Ms. Gloria Bennington i
U. S. Nuclear Regulatory Commission
. Spent Fuel Program Office
- O~ MMO-
-Mail Stop.0 6 F-18 11555 Rockville Pike
- Rockville, MD 20852-2738 Telephone (301)415-8524
Dear Ms; Bennington,
NAC International (NAC) is acting as the general licensee for an irradiated fuel shipment for the l Department-of Energy (DOE) moving from Indonesia and Republic of Kore-Idaho National-
' Engineering and Environmental Laboratory (INEEL) via Naval Weapons Station (N s. S), Concord, CA.
. Per 10CFR 73.26, NAC International (NAC) is hereby requesting NRC approval of a spent fuel route for rail movement between NWS and INEEL.
-Carno DeNerintion:
/20 Cargo will consist of Training Reactor and Isotopes Production, General Atomics (TRIGA) fuel elements containing highly enriched uranium (HEU), not to exceed a total of 42 elements each in four
-(4) NAC LWT casks.' This is in accordance with our Cenificate of Compliance USA /9225/B(U)F for
- these packages.
Schedule:.
The shipment is scheduled for arrival at NWS during the first week of April,1998.
- Pronosed Route:
The proposed route and rail miles comprising each route segment is provided in Attachment 1.
i h
The urbanized areas along the proposed route that we have identified are as follows:
' li. Concord,' CA J L2. Vallejo,CA
- 3. Ogden, UT
] \\
_ 4.~ ; Pocatello, ID.
j i
- [
ptQ h
~
_C PDR w,, g z
A ll A N1 A \\ :W A $ H l N C l o N-
'N E w Y o u t; Z uric H
-LONDON T O K Y o ---
M osco w-
=
A
..m-.
-A*i-4 Asu 3 u.,..asy..
w e. a.
+.
s
-4.%
r t.
a
-l
- I
- hygc; iWWINTERNATIONAL l
(Ms~ Gloria Bennington;
' December'4,1997 I
m
- l
! Page 2 of 2 ;
~
3 Y
E Physical Protection Arrannemer.ts:
- i 15 Escort arrangements will be made by utilizing a caboose outfitted to accommodate security -
~
. personnel for the entire trip, i 2. L Local law enforcement officers will be made aware of the shipment through the required state l
notificasions.-
- 3. 6The communications center will be at the TRANSCOM facility in Oak Ridge, TN.
- Please contact myself, Tom Shelton, or Jim Viebrock with any questions or comments.
e
. i
- Sincerely,;
1
.BI e R.' Williams':
- Manager, Transportation Management Site and Transponation Servic:s
--BRW/sms
- Attachmenti
- :o icc::
Tom Shelton 4 Jim Vicbrock
^
^
- Roy Boyd,
SG61102:-
k
)
l f
.r s
h g
3
.j-
~'
=1 4
m
, 43 4
- b 4.
.,i
_-+J
+
_~N-
'4 y
lT
+.,
v ;;,
r I.
[ M!NS gg t
i
~
al.
l e
4 ga
. yn
~ <
3 -
m
+
^
,p p
y t
p j
Proposed Rail Route NWS, Concord, California to INEEL, Scoville, Idaho Attachment I State Segment Start End Miles Rail CA 1
NWS Avon, CA
<2 Navy CA 2-Avon, CA Sacramento, CA 62 A Mainline CA 3-Sacramento, CA Roseville, CA 15 A Mainline CA, 4
Roseville, CA NV State Line 104 B Mainline CA miles 183 NV 4
NV State Line Winnemucca 195 B Mainline NV 5
Winnemucca, NV Alazon, NV 175 A Mainline NV 6
Alazon, NV UT State Line 64 B Mainline NV miles 434 UT 6
UT State Line Ogden, UT 109 B Mainline UT 7
Ogden, UT ID State Line 62 A Mainline UT miles 171 ID 7
ID State Line l'ocatello, ID 75 B Mainline ID 8
l'ocatello, ID Scoville,ID 21 B Mainline 35 B Branchline ID miles 131 Total 919 miles