ML20198R815
| ML20198R815 | |
| Person / Time | |
|---|---|
| Site: | 07105450 |
| Issue date: | 05/28/1986 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | Nardi A WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP. |
| References | |
| NUDOCS 8606100221 | |
| Download: ML20198R815 (2) | |
Text
_ _ _ _ _ _ _ _. __
4f~[WO
% TO k Me 39843 FCTC:CEp MAY2811NE 71-5450 Westinghouse Electric Corporation ATTH: Ifr. A. J. Nardi P.O. Box 355 Pittsburgh, PA 15230 Centlemen:
This refers to your consolidated application dated December 20,1985, as supplenented April 23, 1986, for renewal of Certificate of Compliance No. 5450 for the l'odel No. RCC-Series packages.
In connection with our review, we need the information identified in the enclosure to this letter.
The information requested should be submitted within 30 days from the date of this letter. Additional information requested by this letter should be subnitted in the forn of revised pages.
If you have any questions regarding this natter, w would be pleased to meet with you and your staff.
Sincerely, Os v..;igned by CHARLES E !W'DONALU Charles E. l'acDonald, Chief Transportation Certification Branch Division of Fuel Cycle and t'aterial Safety, HMSS
Enclosure:
As stated Distribution: w/ enc 1 IEWilliams CRMarotta RH0degaarden Docket File NRC PDR 8606100221 860528 DR ADOCK 0710 0
IE HQ C
Region I q
NMSS R/F l
FCTC R F p -p i-FCTC
-FCTC l
FCTC o~
EW1111ams fal ' CRMa'rotta"
~R Od4gaafdeii CE oMnald ~
05M//86 05/S?/86 05/,g/,86 05h86
==>
nne eonu ata cio aoi $4Wo24o
~
OEFICIAL RECORD COEY
Uestinghouse riectric Corporation Model Pos. PCC, RCC-1, CCC-?, 9CC-3, and PCC-4 packaces DocFet Mo. JUST50 Encl to ltr dtd:
1.
Section 2.G, Forral Corditions of Transport. The conpressive load requirenent, 571.71(9), rust be addressed for packages ueiching up to 5,000 Pg.
2.
Crawinc Pos. SKD-36009, 3 sheets and SV.0-86009 tmre revised, according to Attachrent No. I to Festingbouse letter dated April 28,1985, to describe in detail the naterial specifications, ucid. joint sizes, and conponent dinensions. The drawings picture various too closure asserblies but do not orovide inforration on raterials of construction, weld joint sizes, or conporent dinensions. The drawings should be revised to provide the inforration requested.
3.
nrawing "o. SPD-060ll, " Fuel Asse,bly Shipping Container Internals Clanpinn Frane Assenhly," was subnitted to provide additional dironsional inforna tion. The drawing nrevides no dirensional infornation and no inforriation on the materials of construction except for fasteners and a note "C" which is not referenced by any iten on the drawing. The drawing should be revised to provide the inforration requested.
4.
The response to questions "o. 13 and 15 of P'.C letter dated February 20, 198G, needs to be clarified. Two different "ilitary Standards are cited and each at two different revision levels.
Please provide a copy of "IL-STD-242.
"ict >
$""^*'>
D A M )j.......
nnc ronu m no soi sncu om OFFICIAL RECORD COPY