ML20198R574

From kanterella
Jump to navigation Jump to search
Registry of Radioactive Sealed Sources & Devices,Safety Evaluation of Device for Models Scs 1001 Through 1008. Certificate:NR-8105-S-806-S
ML20198R574
Person / Time
Issue date: 01/05/1999
From: Steven Baggett, Michele Burgess
NRC
To:
Shared Package
ML20198R564 List:
References
SSD, NUDOCS 9901080228
Download: ML20198R574 (3)


Text

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO.: NR-8105-S-806-S DATE: January 5, 1999 PAGE 1 OF 3 DEVICE TYPE:

Calibration Sources MODEL:

SCS 1001 through 1008 MANUFACTURER / DISTRIBUTOR:

ThermoRetec (Formerly TMA/Eberline) 7021 Pan American Freeway, NE Albuquerque, NM 87109

, ISOTOPE:

MAXIMUM ACTIVITY:

Cesium-137 180 Ci (6.66 TBq)

LEAK TEST FREOUENCY:

6 Months PRINCIPAL USE1 (I) Calibration Sources (Activity greater than 30 mci)

CUSTOM DEVICE:

YES X

NO 9901090228 990105 PDR RC SSD PDR

'i

\\

0 '10101 0 12 3 l

\\

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO.-

NR-8105-S-806-S DATE: Jmnury 5, 1999 PAGE 2 OF 3 DEVICE TYPE:

Calibration Sources pESCRIPTION:

These sources are manufactured by CEA France.

The radioactive compound in the SCS 1001 through 1007 type source is a sintered pollucite pellet (cesium sillico aluminate) with very low dissolving rate.

SCS 1001 through 1007 capsules are 6.2 mm (0.24") outer diameter by 14 mm (0.55") height.

Th radioactive compound for the SCS 1008 type source is cesium chloride pellets.

SCS 1008 capsules are 19 mm (0.75") outer diameter by 30 mm (1.18") height.

Both types of sources are doubly encapsulated in a stainless steel capsule sealed by argon arc welding.

CEA France furnishes sources and wipe test certificates to Eberline.

Eberline wipes sources before assembly into calibrator and furnishes leak test certificate to buyer of calibrator.

LABELING:

Individual sources were identified by a serial number.

They were used only in the Eberline Model 1000B calibrator and are normally inaccessable to the user. (See device catalog sheet for calibrator.)

PROTOTYPE TESTING:

Both types of sources meet the requirements of "special form".

SAFETY ANALYSIS

SUMMARY

The Model SCS 1001 through 1008 sources are no longer manufactured or distributed by ThermoRetec and ThermoRetec has no intention to produce them any more in the future.

Therefore, the registration certificate is being converted to an inactive registration certificate.

\\

\\

l

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE NO,.'NR-8105-S-806-S DATE: January 5, 1999 PAGE 3 OF 3 DEVICE TYPE:

Calibration Sources SAFETY ANALYSIS

SUMMARY

(Cont'd):

The sources were originally approved for licensing purposes by the State of New Mexico and this certificate is recently returned to the NRC.

Because of the limited information available on this unit, no safety evaluation of the device was performed as part of the conversion of the certificate to inactive status.

ISSUING AGENCY:

U.S. Nuclear Regulatory Commission Date:

inru m nr 9 1000 Reviewer: NeIM JM Michele'B'urgess" 7

Use#

Date:

Jtnuary 5,1999 Concurrence:

f *

'S't'even Baggett c

I i

\\

\\

\\

\\\\t\\

_