. . - _- . . - --

Decenber 21, 1998 Mr. Ted C. Feigenbaum Executive Vice President and Chief Nuclear Officer North Atlantic Energy Service Corporation c/o Mr. Terry L. Harpster P.O. Box 300 Seabrook, NH 03874

SUBJECT:

REVIEW OF RESPONSE TO GENERIC LETTER 97-05," STEAM GENERATOR TUBE INSPECTION TECHNIQUES," SEABROOK STATION, UNIT 1 (TAC NO.

MA0493)

Dear Mr. Feigenbaum:

By letter dated March 17,1998, North Atlantic Energy Service Corporation (NAESCO) responded to Generic Letter (GL) 97-05, " Steam Generator Tube Inspection Techniques," for the Seabrook Station, Unit 1 (Seabrook). The focus of the GL was to verify that steam generator tube inspection practices were consistent with existing regulatory requirements and plant licensing bases. NAESCO's response included a description and technical basis for all inspection techniques used to size the depth of steam generator tube degradation at Seabrook.

The staff has completed its review of your response to GL 97-05 and did not identify any concerns with the steam generator tube inspection techniques employed at Seabrook that would indicate that NAESCO is not in compliance with the current licensing basis for this facility.

This completes the staff's review of the subject GL for Seabrook.

Sincerely, Original signed by:

- John Harrison, Project Manager Project Directorate 1-3 Division of Reactor Projects - l/Il Office of Nuclear Reactor Regulation Docket No. 50-443 cc: See next page f

)lSTRIBUTION 0 hehetFile]p C. Cowgill J. Harrison P. Rush PUBLIC OGC T. Clark E. Murphy Seabrook r/f ACRS J. Zwolinski A. Dromerick DOCUMENT NAME: G:\ Harrison \MA0493.gl

To receive a copy of this document, indicate in the box
"C" = Copy without attachment / enclosure "E" = Copy with attachment / enclosure "N" = No copy OFFICE PDI-3/PM l PDI-3/LA ,CA lD PDI-3/D ty2, e l l l '

l NAME JHarrison _M TClark_ MJ CThomas ' AJyt, DATE lD 1l /98 /d,/ M l~298 s2/ Al /# / /98 OFFICIAL RECORD COPY 9901070390 981221 ~ . . , c,mpa PDR ADOCK 0500 3 yg gf

{gr sm _ m.

aung i

t f

2 j UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. ennam -1

\M. . . . . so# December 21, 1998 Mr. Ted C. Felgenbaum Executive Vice President and Chief Nuclear Officer North Atlantic Energy Service Corporation c/o Mr. Terry L. Harpster P.O. Box 300 Seabrook, NH 03874 i

SUBJECT:

REVIEW OF RESPONSE TO GENERIC LETTER 97-05," STEAM GENERATOR TUBE INSPECTION TECHNIQUES," SEABROOK STATION, UNIT 1 (TAC NO.

MA0493)

Dear Mr. Feigenbaum:

By letter dated March 17,1998, North Atlantic Energy Service Corporation (NAESCO) responded to Generic Letter (GL) 97-05, " Steam Generator Tube Inspection Techniques," for the Seabrook Station, Unit 1 (Seabrook). The focus of the GL was to verify that steam generator tube inspection practices were consistent with existing regulatory requirements and plant licensing bases. NAESCO's response included a description and technical basis for all L

inspection techniques used to size the depth of steam generator tube degradation at Seabrook.

The staff has completed its review of your response to GL 97-05 and did not identify any l concerns with the steam generator tube inspection techniques employed at Seabrook that would indicate that NAESCO is not in compliance with the current licensing basis for this facility.

This completes the staff's review of the subject GL for Seabrook.

, Sincerely, j i -

i l

h i

i ohn Harrison, Project Manager Project Directorate 1-3

, Division of Reactor Projects - 1/II L_ ,. Office of Nuclear Reactor Regulation , ,

1.

! Docket No. 50-443 cc: See next page i

l T. Felgenbaum North Atlantic Energy Service Corporation Seabrook Station, Unit No.1 cc:

Lillian M. Cuoco, Esq. Mr. Peter LaPorte, Director Senior Nuclear Counsel ATTN: James Muckerheide Northeast Utilities Service Company Massachusetts Emergency Management P.O. Box 270. Agency Hartford, CT 06141-0270 400 Worcester Road P.O. Box 1496 Mr. Peter Brann Framingham, MA 01701-0317 Assistant Attorney General State Hou' se, Station #6 Jeffrey Howard, Attorney General Augusta, ME 04333 b G. Dana Bisbee, Deputy Attorney General Resident inspector 33 Capitol Street U.S. Nuclear Regulatory Commission Concord, NH 03301 Seabrook Nuclear Power Station P.O. Box 1149 . Mr. Woodbury Fogg, Director Seabrook, NH 03874 New Hampshire Office of Emergency Management Jane Spector State Office Park South Federal Energy Regulatory Commission 107 Pleasant Street 825 North Capital Street, N.E. Concord, NH 03301 Room 8105 Washington, DC 20426 Mr. Roy E. Hickok Nuclear Training Manager Town of Exeter Seabrook Station 10 Front Street Exeter, NH 03823 North Atlantic Energy Service Corp.

P.O. Box 300

. Seabrook, NH 03874 -

Regional Administrator, Region i U.S. Nuclear Regulatory Commission Mr. Terry L. Harpster 475 Allendale Read Director of Licensing Services King of Prussia, PA 19406 Seabrook Station North Atlantic Energy Gervice Corp.

Office of the Attorney Gen 9ral P.O. Box 300 One Ashburton Place. Seabroo'<, NH 03874 20th Floor Boston, MA 02108 Mr. W. A. DiProfio Station Director Board of Selectmen Seabrook Station v~ - ~~ ~

" Town of Amesbury '

North Atlantic Energy Se'rvice Corporation Town Hall _ P.O. Box 300 Amesbury, MA 01913 Seabrook, NH 03874 Mr. Dan McElhinney Federal Emergency Management Agency Region 1 J.W. McCormack P.O. &

Courthouse Building, Room 401 Boston, MA 02109

~ -.-

l

-0 s

. 2 Mr. Frank W. Getman, Jr.

20 International Drive Suite 301 Portsmouth, NH 03801-6809 Mr. B. D. Kenyon President - Nuclear Group Northeast Utilities Scrvice Group P.O. Box 128 Waterford,CT 06385 h Mr. David E. Carriere Director, Production Services Canal Electric Company 2421 Cranberry Highway Wareham, MA 02571 g 6 7 , . . e ,-..e.-+, san-. e-+w.--4Mm+=-=+ en~=+ * --*-' - " ' ' * '

i. .. .

- _ _ _ - - - - _ - - - _ - - - .a