{{#Wiki_filter:,. 3... ,t January 21, 1998 d MEMORANDUM TO: Thomas H. Essig, Acting Chief Generic issues and Environmental Projects Branch Division of Reactor Program Management Office of Nuclear Reactor Regulation . FROM; Stewart L. Magruder, Project Manager original.. signed by: Generic issues and Environmental Projects Branch Division of Reactor Program Management Office of Nuclear Reactor Regulation -
SUBJECT:
NOTICE OF MEETING WITH COMBUSTION ENGINEERING OWNERS GROUP (CEOG) REGARDING MAIN STEAM LINE BRtIAK (MSLB) ACCIDENT ANALYSIS DATE AND TIME: January 29,1998 - 8:30 a.m.~- 11 a.m. LOCATION: U.S. Nuclear Regulatory Commission - Two White Flint North 11545 Rockville Pike Rockville, Maryland 20852 Room T-10 F3 PURPOSE: To discuss CEOG activities related to analysis of moisture carryover during a MSLB accident. A proposed agenda is attached. PARTICIPANTS: ILR_Q CEOG E. Weiss D. Streinz F. Orr M. Janke J. Kudrick P. Hijeck, et al. S. Magruder, et al. Project No. 692
Attachment:
As stated cc w/atts: See next page Meetings between the NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenorc, or other parties to attend as observers pursuant to " Commission Policy Statement on Staff Meeting Open to the Public," 59 Eederal Reaister 48344,9/20/94 Members of the public who wish to attend should contact Stewart Magruder at ) (301) 415-3139. n g lO).ii DISTRIBUTION: e See next page _ gch DOCUMENT NAME: A:\\MTG0129A.NOT.
- To receive a copy of tale document, ind ate in the box: "C" = Copy without attachment / enclosure "E" = Copy with attachment / enclosure "N" = No copy a
l OFFICE - PM:PGEB:DRPM [ '- SC:PC $3sVM l l l lNAME SMagruder.sg <;Lra FAkBfe'wicz - 'lDATE' 01/2\\/98 01/', b8 OFFICIAL RECORD COPY 9901220235 990'121 7 7P/[ l g ' g-{ g S C F EJi: C U R R C 8 P T gaa T7a;E=c;g, 3
'9 , :s
- l.,
a - CE OWNERS GROUP P.oject No. 692 cc:- Mr. Gordon C. Bischoff CEOG Project Manager ABB Combustion Engineering M.S. 96151932. 2000 Day Hill Road Windsor, CT 06095 - Mr. David Pilmer, Chairman CE Owners Group San Onofre Nuclear Generating Station 14300 Mesa Road San Clemente, CA 92672 Mr. Charles B. Brinkman, Director Nuclear Systems Licensing ABS-Combustion Engineering, Inc. Post Office Box 500 2000 Day Hill Road Windsor, CT 06095 Mr. Charles B. Brinkman, Manager Wcshington Nuclear Operations ' ABB-Combustion Engir Toring, Inc. 12300 Twinbrook Parkw t, Suite 330 ' Rockville, MD 20852 o 4 5 r m.-3
CEOGINRC MEETING ON MSLB MOISTURE CARRYOVER PROPOSED AGENDA JANUARY 29,1998 8:30 Introductions-All 8:35 Meeting Purpose and Goals - CEOG Analysis Subcommitte Representative Apprise the Staff of CE0G activities and tentative plans Seek Staff input / insight on technical approach and identify any current concoms Discuss the appropriate timing of submittal of potential topical report 8:45 Overview of Phase i Findings - Don Streinz (ABB) 9:00 Moisture Carryover - Don Streinz (ABB) Laboratory Tests input Algorithm Development 9:30 Main Steam Line Break Results - Mark Janke (ABB) Reactivity Change Containment Mass and Energy Discussion 10:30 CEOGINRC Planning Discussion - D. Streinz lesd/all Topical Development Submittal Schedule NRC Staff Review Horizon 11:00 Adjoum Attachment
' ] = g, 4 ~ DISTRIBUTION, Memorandum *,a_ Thomas H. Essin. Dated: January 21. 1998 Project Files tCentral F#es'- PUBUC PGEB R/F 000 ACRS SMagruder TWFN Receptionist fJstil SCollins/FMitaglia BSheron RZimmerman JRoe DMatthews , TEssig FAkstulewicz SMagruder GHolahan SNewberry TCollins CBeninger-EWeiss. Fort JKudrick CJackst.1 GTracey, OEDO _ PMNS OPA 1 (s r .T, = _m.m m.m&_-_..-...a-- A_}}