ML20198P086

From kanterella
Jump to navigation Jump to search
Application for Rev to Certificate of Compliance 9019 for Model BU-7,to Allow Option of Shipping uranium-bearing Matls in Package Without Boral Liner
ML20198P086
Person / Time
Site: 07109019
Issue date: 12/30/1998
From: Vaughan C
GENERAL ELECTRIC CO.
To: Chappell C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
Shared Package
ML20198P091 List:
References
CMV-98-040, CMV-98-40, NUDOCS 9901060304
Download: ML20198P086 (1)


Text

,

~0l$0h s

GENuclear Energy l

Cows!Datac Comtuny PO Ban 700. Wdmmytm NC26402 910 6?S 5000 December 30,1998 I

Mr. Cass R. Chappell, Chief Package Certification Section I

Spent Fuel Project Office, NMSS U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001

Subject:

Revision Request

Reference:

(1)

NRC Certificate of Compilance USA /9019/AF (2)

Docket Number 719019 GE's Nuclear Energy Production (NEP) facility in Wilmington, N.C. hereby requests NRC approval of revised wording to the BU-7 Certificate of Compliance 9019 to allow the option of shipping uranium-bearing materials in the package without the boral liner.

Condition 5.(b)(2)(iii) of the COC currently requires a boralliner to be used when shipping uranium-bearing material as described in Condition 5.(b)(1)(iii). The criticality safety analysis, e

enclosed with this letter as Appendix J, demonstrates that 13.22 kgs of uranium at a maximum of 5.00 w/o U235 may be safely shipped without a boral liner inside the inner container provided the minimum transport index is 0.2.

The following is suggested wording for the COC, if the NRC approves the request:

5.(b)(2)(iii) should be changed to add the following wording. " Maximum 13.22 kgs uranium per package without the boral liner.

5.(b)(2)(c), Transport Index for Criticality Control should be changed as follows:

(i) Minimum transport index to be shown on label for 0.4

{

nuclear criticality control with boral liner (ii) Minimum transport index to be shown on label for 0.2 nuclear criticality control without boral liner Six (6) copies of this application are being provided for your use.

I Please contact Rick Foleck on (910) 675-6299, Scott Murray on (910) 675-5950 or me if you have any questions or would like to discuss the matter further.

\\

/

Ij \\O Sincerely, 9901060304 981230 T[q

[DR ADOCK 0710901g 3E NUCLEAR ENERGY

,, PDR Q R

Charles M.

a n, Manager Facility Licensi hp kl.

Attachments Q

,/d GO cc:

CMV-98-040

[/Y)

/

O