ML20198M339
| ML20198M339 | |
| Person / Time | |
|---|---|
| Site: | South Texas |
| Issue date: | 12/28/1998 |
| From: | Hannon J NRC (Affiliation Not Assigned) |
| To: | Cottle W HOUSTON LIGHTING & POWER CO. |
| Shared Package | |
| ML20198M342 | List: |
| References | |
| TAC-MA3945, NUDOCS 9901050312 | |
| Download: ML20198M339 (3) | |
Text
.
's Mr. William T. Cottle December 28, 1998 President and Chief Executive Officer STP Nuclear Operating Company South Texas Project Electric Generating Station P. O. Box 289 Wadsworth, TX 77483
SUBJECT:
INSERVICE INSPECTION PROGRAM - RELIEF REQUEST RR-ENG-27, SOUTH TEXAS PROJECT, UNIT 2 (TAC NO. MA3945)
Dear Mr. Cottle:
By letter dated September 30,1998, STP Nuclear Operating Company (STPNOC) submitted a request for relief from the ASME Code,Section XI requirements, to defer Code repair of a flaw identified in the Essential Cooling Water System (ECWS) piping at the South Texas Project, Unit 2. The Nuclear Regulatory Commission (NRC) staff has reviewed the requect as discussed in the enclosed Safety Evaluation.
The staff finds that the performance of an immediate Code repair would result in hardship or unusual difficulty without a compensating increase in the level of qua'ity and safety. T ne staff, therefore, concludes that STPNOC's proposed al+.rnatives to the Code requirements are authorized pursuant to 10 CFR 50.55a(a)(3)(ii).
Sincerely, ORIGINAL SIGNED BY:
John N. Hannon, Project Director Project Directorate IV-1 Division of Reactor Projects Ill/IV j
Office of Nuclear Recctor Regulation Docket No. 50-499
Enclosure:
As stated J
cc w/ encl: See next page DISTRIBUTION:
Docket File PUBLIC PD4-1 r/f TGwynn, RIV DLange
([
EAdensam (EGA1)
JHannon CHawes THarris(TLH3)
[' \\TV j TAlexion OGC ACRS GHill(2)
Document Name: G:\\STPFINAL\\STPA3945.REL f)
/
Plf/ D4-1 OFC PM/Pp4-1, LA/PD4-1. _
BCdQDB OC TAlexih IB Mh NAME CHa hi JHannon DATE M /98 lN /98 all\\ /98 p//7 /
/M2f/98 YES h /
ES)NO COPY lY'bbNO YES/NO YES/NO
{/
OFFICIAL RECORD COPY
'gnfsb129s122a 7
PDR ADOCK 050004 9 a 6 P
pn nt; t
UNITED STATES g
j NUCLEAR RECULATORY COMMISSION 2
WASHINGTON, D.C. 20066-0001 p%pOV /
December 28, 1998 Mr. William T. Cottle President and Cnief Executive Officer STP Nuclear Operating Corrpany South Texas Project Eledric Generating Station P. O. Box 289 Wadsworth, TX 77483
SUBJECT:
INSERVICE INSPECTION PROGRAM - RELIEF REQUEST RR-ENG-27, SOUTH TEXAS PROJECT, UNIT 2 (TAC NO. MA3945)
Dear Mr. Cottle:
By letter dated September 30,1998, STP Nuclear Operating Company (STPNOC) submitted a request for relief from the ASME Code,Section XI requirements, to defer Code repair of a flaw identified in the Essential Cooling Water System (ECWS) piping at the South Texas Project, Unit 2. The Nuclear Regulatory Commission (NRC) staff has reviewed the request as discussed in the enclosed Safety Evaluation.
The staff finds that the performance of an immediate Code repair would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety. The staff, therefore, concludes that STPNOC's proposed attematives to the Code requiremea'.s are authcrized pursuant to 10 CFR 50.55a(a)(3)(ii).
Sincer N
John N. Hannon, Project Director Project Directorate IV-1 Division of Reactor Projects Ill/IV Office of Nuclear Reactor Regulation Docket No. 50-499
Enclosure:
As stated cc w/ encl: See next page l
1, Mr. William T. Cottle STP Nuclear Operating Company South Texas, Units 1 & 2 cc:
Mr. Cornelius F. O'Keefe Jack R. Newman, Esq.
Senior Resident inspector Morgan, Lewis & Bockius U.S. Nuclear Regulatory Commission 1800 M Street, N.W.
P. O. Box 910 Washington, DC 20036-5869 Bay City, TX 77414 Mr. Lawrence E. Martin
. A. Ramirez/C. M. Canady Vice Plesident, Nuc. Assurance & Licensing City of Austin GTP Nuclear Operating Company Electric Utility Department a, O. Box 289 721 Barton Springs Road
.Wadsworth,TX 77483 Austin, TX 78704 Office of the Governor Mr. M. T. Hardt ATTN: John Howard, Director Mr. W. C. Gunst Environmental and Natural City Public Service Board
- Resources Policy P. O. Box 1771 P. O. Box 12428 San Antonio, TX 78296 Austin,TX 78711 Mr. G. E. Vaughn/C. A. Johnson Jon C. Wood Central Power and Light Company Matthews & Branscomb P. O. Box 269 One Alamo Center Mail Code: N5012 106 S. St. Mary's Street, Suite 700 Wadsworth,TX 74483 San Antonio, TX 78205-3692 INPO Arthur C. Tate, Director Records Center Division of Compliance & Inspection 700 Galleria Parkway Bureau of Radiation Control Atlanta, GA 30339-3064 Texas Department of Health 1100 West 49th Street Regional Administrator, Region IV Austin,TX 78756 U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Jim Calloway Arlington,TX 76011 Public Utility Commission of Texas Electric Industry Analysis D. G. Tees /R. L. Balcom P. O. Box 13326 Houston Lighting & Power Co.
Austin, TX 78711-3326 P. O. Box 1700 Houston,TX 77251 Judge, Matagorda County Matagords County Courthouse 1700 Seventh Street Bay City, TX 77414
=
- ~.... - -..
.n.-
-