ML20198K434
| ML20198K434 | |
| Person / Time | |
|---|---|
| Site: | Hope Creek |
| Issue date: | 06/02/1986 |
| From: | Corbin McNeil Public Service Enterprise Group |
| To: | Adensam E Office of Nuclear Reactor Regulation |
| References | |
| NUDOCS 8606040027 | |
| Download: ML20198K434 (1) | |
Text
,.
Pubhc Service Electric and Gas Comparty Corbin A. McNeill, Jr.
Public Service Electoc and Gas Company P.O. Box 236, Hancocks Bridge. NJ 08038 609 339-4800 vice Presedent -
Nuclear June 2, 1986 Director of Nuclear Reactor Regulation United States Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, Maryland 20814 Attention:
Ms. Elinor Adensam, Director Project Directorate 3 Division of BWR Licensing
Dear Ms. Adensam:
COMPLETION OF PREOPERATIONAL TESTING FOR THE TRAVERSING-INCORE-PROBE SYSTEM HOPE CREEK GENERATING STATION DOCKET NO. 50-354 Public Service Electric and Gas Company (PSE&G) on May 23, 1986 successfully completed preoperational tests for the Traversing-Incore-Probe (TIP) system in support of HCGS Operating License Condition 2.D(b) and the continuation of low power testing activities.
If there are any questions with regard to this letter, do not hesitate to contact us.
Sincerely, C
D.H. Wagner USNRC Licensing Project Manager R.W.
Borchardt USNRC Senior Resident Inspector g0k 6
8606040027 860602 PDR ADOCK 05000354 P
-_--