RETURN TO. 3%-SS 7/_ ggj CHEM -NUCLEAR SYSTEMS, INC.

135 Darling Drive

~

Q RECEIVED 7

k JAN 31986 >

u.s.nucttARRtcutaroar b w

co m w an December 30, 1985 uQ y

k j; C8512-13

!!r. Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, Nf1SS U.S. Nuclear Regulatory Commission Washington, D. C.

20555

Subject:

Docket flo. 71-6601, CNS 8-120

Reference:

(A) NRC letter dated October 29, 1985 C. E. MacDonald to Chem-fluclear Systms, Inc.

Dear ftr. MacDonald:

Please find enclosed eight copies of the Revision 1 update to the CNS 8-120A SAR. This revision incorporates corrections and claHfications in response to items identified in Reference (A). Attachment One to this 'etter provides an itemized response to each NRC coment for your convenience.

Please feel free to contact us if any further information is needed.

Very truly yours, O

D' -

A CHEM-NUCLEAR YSTEMS, INC.

Dacarito be'>&

Oh!

00 6 'S Robert T. Anderson

{

g,8ferlay svg Director, Cask & Transportation Systems og, city 3

N

/qfs

/

P I '-

I l

0877V cc:

V. Barnhart, L. Poppe, C. Hathaway, L. Toner, File G.2.12 l

i'" *i' TP.?. m n y n d L L L j! g s s > j;a 64 6A'l A]p 060130025005{gjjot ADOCK 07

{DR PDH

]

ATTACHf1ENT ONE TO C8512-13 CNSI Response to NRC Comment Letter dated October 29, 1985 MODEL CNS 8-120 DOCKET 71-6601 1.

HRC C0fHENT:

The packaging drawing does not show the modification authorized by condition 11 of the certificate of compliance (Chen-fluclear letter of Decemberj, 1980).

8 CNSI RESPONSE:

The package drawing has been revised (General Hote 12 added) to permit plug handles to be replaced by 1-1/2" square har stock.

2.

NRC C0fiMENT:

The drawing should note the specific dimensions effected by drawing Note 5.

Previous packaging drawings noted its application.

CNSI RESPONSE:

General Note 5(B) has been revised to indicate that the + 1/4" tolerance is applicable to the 78-1/2" length of the inner shells.

3.

NRC COMfiENT:

The material specification (ASTM A-285-C) cited for part Numbers 31 and 39 should be reviewed to detemine if the specification covers 1/16" thick sheet steel.

CNSI RESPONSE:

ASTM A285 limits naximun plate thickness to 2" for this specification however there is no limitation imposed for minimum thickness. The material for part numbers 31 and 39 is a sheet steel with the composition and material properties specified in ASTM A?85 for plate.

4 NRC COMf1ENT:

Part Numbers 6, 27, and 29, which are listed in the Bill of Material, should be shown on Sheet 1 of the packaging drawing.

CNSI RESPONSE:

Part Nunbers 6 and 29 have been identified on the package drawing.

Part number 27 has been deleted since it was replaced by iten 41.

5.

NRC C0ffiENT:

The dimensional information for Part 20, in the Bill of Material, should be corrected.

CNSI RESPONSE:

The 7-1/2" dimension was corrected to read 71-1/2" nominal.

6.

NRC C0fif1ENT:

On sheet 1 of the packaging drawing, Zone E6, the number of 2-1/2" diameter pour and vent holes should be specified.

CNSI RESPONSE:

The package drawing has been revised to identify that there are three pour and vent holes.

7.

NRC C0ft1ENT:

(Section 1.2)

Correct the inconsistency between the description and the drawing relative to the location of the drain port.

CNSI RESPONSE:

The drain port location dimension in Section 1.2 has been corrected.

8.

NRC C0ffiENT:

(Section 4.4)

The time peried cited in the first paragraph should be revised to require, "twice the expected shipment time".

CNSI RESPONSE:

Required time period has been revised as requested.

i

INSTRUCTIONS FOR REVISIGH 1 UPDATE TO CHS 8-120(A) SAR REMOVE INSERT Title Page rev 0 Title Page rev 1 p 1-1 rev 0 p 1-1 rev 1 p 1-2 rev 0 p 1-2 rev 1 CHSI Drawing 29008-1 CNSI Drawing 29008-1 sheet 1 (no rev) sheet 1 rev 1 General Hotes (2 pages)

General Notes rev 1 page 1 of 2 and 2 of 2 CNSI Drawing 29008-1 CHSI Drawing 2900R-1 Sheet 2, Bill of Material (no rev) sheet 2, Bill of Haterial rev 1 p 4-2 rev 0 p 4-2 rev 1