ML20198G597

From kanterella
Jump to navigation Jump to search
Forwards Request for Addl Info Re 850409 Application for Amend to Certificate of Compliance 9151 for Model HN-100 Series 3 Package.Response Should Include Packaging Drawings That Ref Correct ASME Std,SE-165
ML20198G597
Person / Time
Site: 07109151
Issue date: 05/20/1986
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Leduc R
WESTINGHOUSE HITTMAN NUCLEAR, INC.
References
NUDOCS 8605290692
Download: ML20198G597 (2)


Text

, _ _ _ _ _ _ _ _ - _ _

  • 7 / -9 /II A%y R

ku,,

396.ss FCTC: RHO 71-9151 E2 0 M Westinghouse Hittman ikielear Incorporated ATTN: Mr. Robert J. Leduc 9151 Rumsey Road Columbia, MD 21045 Gentlemen:

This refers to your application dated April 9,1985, as supplemented, requesting an anendment to the fbdel fio ifN-100 Series 3 package.

In connection with our review, we need the information identified in the enclosure to this letter.

Please advise us within 30 days from the date of this letter when this infomation will be provided. Additional information requested by this letter should be subnitted in the fom of revised pages. If you have any questions regarding this natter, we would be pleased to neet with you and your staff.

Sincerely.

0*irirmi Sic ed by N 3. M&GD(Egg)

Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety,feiSS

Enclosure:

As stated Distribution: w/ encl Docket File NRC PDR IE HQ Region I RH0degaarden (2)

DTHuang CEWilliams fMSS R/F B605290692 DR 860520 FCTC R/F C ADOCK 0710 1 m m Jl "'**#* edssFdenisis"5THuand' FCTC FCTC

..FCTC 1111ains

'lrCTC T cDonafd "05//g/8s""dsg.0/56" om, "05T/5786" "05/f5786" i NRC FORM 318 (10-80) NRCM O240 OFFICIAL RECORD COPY

Hestinnhouse Hittnan Nuclear Incorporated t'odel Ho. HN-100 Series 3 Packane Pocket No. 71-9151 Enc 1 to ltr dtd: MAY 2 0 W DP.AUIt!GS 1._ The packaging drawings have been revised to specify the nondestructive exanination requirenents as referenced in Section 7.0. However, '

the note does not correctly cite the ASME Standard. The standard

. is in Section V, Article 24 of the ASME Code and is designated as SE-165

2. Analysis of the tie-down lug on page 22 of the safety analysis report specifies the dinensions of the 1/2-inch reinforcing plates. These

, dinensions should be shown on the packaging drawings.

3. The caterial specification for the snacers, Iten 6, Orawing No. C001-S-9140, Rev. 7 and Iten 10 Drawing No. C001-5-9139 should be consistent and the "or equivalent" should be deleted.

j I

(

1  !

3 a

,l-1 4

OFFICE) ............ ............. ............. .............. ............. ............. .............

CURNAME) ............ ............. ............. .............. ............. ............. .............

DATE) ............ ............. ............. ............. ............. ............. .. ........,,

nnc Fonu ais sio soi nacu o24o OFFICML. RECORD COPY