Discusses 970805 Meeting W/Util in Region IV Ofc Re Util Progress in Resolving long-standing Issues Involving Instrument Setpoint & Scaling Programs at Plant,Units 1 & 2. List of Attendees & Presentation Matl Encl
ML20198G170
Person / Time
Site: South Texas  
Issue date: 08/08/1997
From: Howell A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Cottle W
HOUSTON LIGHTING & POWER CO.
References
NUDOCS 9708130390
Download: ML20198G170 (23)


Text

_ - _ - _ - - - _ _. - _ _

gt ** "* %g UNtit D ST AT Es fm X

NUCLEAR REGULATORY COMMISSION k

HEGION IV bu 4

611 R Y AN PLAi'A DRIVE, SU T1400 i

AH LINGTON, T E X AS N011 R064 n.....--

-August 8 1997 William T. Cottle, Group Vice -

President, Nuclear Houston Lighting & Power Company

- P.O. Box 28" Wadsworth, fexas 77483

SUBJECT:

INSTRUMENT SETPOINT AND SCALING PROGRAMS AT THE SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION

Dear Mr. Cottle:

This refers to the meeting conducted in the Region IV office on August 5,1997. The purpose of this meeting was to discuss HL&P's progress in resolving long-standing issues -

r l

involving the instrument setpoint and scaling programs at South Texas Project Electric -

Generating Station. The attendance list and presentation material are included as Enclosures 1 and 2, respectively.

I During this meeting, South Texas Project personnel presented a historical perspective, the management decision making process involving the resolution of issues involving these programs, and the current status of these programs. Additionally, the scope and schedule of the action plan to resolve remaining issues was also discussed. As indicated during the meeting, we intend to conduct additional inspection followup of this area in the near

future, in accordance with' Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code

- of Federal Regulations, a copy of this lotter will be placed in the NRC's Public Document Room.

Should you have any questions concerning this meeting, we will be pleased to discuss them with you.

Sinc ely,

,4 f

'=t hi Arthur T. How lili Director

}

Division of Reactor Safety

-.9 9708130390 970808 hglglgjg

[g PDR ADOCK 05000498 m

P PDR m

Houston Lighting & Power Company-.

Docket Nos.: 502498; 50-499 License Nos.: ~ NPF 76; NPF 80

Enclosures:

1.- Attendance List

2. Licensee Presentation cc w/ Enclosure 1:

Lawrence E. Martin, General Manager Nuclear Assurance & Licensing

- Houston Lighting & Power Company P.O. Box 289 '

Wadsworth/ Texas 77483

' Mr. J. C. Lanier/Mr. M. B. Lee City of Austin Electric Utility Department "721 Barton Springs Road Austin, Texas - 78704 -

Mr. K. J. Fiedler/Mr. M. T. Hardt

-City Public Service Board.

P.O. Box 1771

- San Antonio, Texas 78296 Jack R.- Newman, Esq.

- Morgan, Lewis & Bockius-

- 1800 M. Street, N.W.

Washington, D.C{ 20036 5869

- Mr. G. E. Vaughn/Mr. C. A. Johnson

' Central Power & Light Company P,0. Box 289

~ Mail Code: N5012 Wadsworth, Texas 77483

' INPO-

' Records Center-

-700 Galleria Parkway

- Atlanta, Georgia 30339-5957 L

y em-3 w

o

Houston Lighting & Power Company Dr. Bertram Wolfe 15453 Via Vaquero Monte Sereno, California 95030 Bureau of Radiation Control State of Texas 1100 West 49th Street Austin, Texas 78756 Mr. Glenn W. Dishong Texas Public Utility Commission 7800 Shoal Creek Blvd.

l Suite 400N Austin, Texas 78757 1024 Andy Barrett, Director Environmental Policy Office of the Governor P.O. Box 12428 Austin, Texas 78711 Judge, Matagorda County Matagorda County Courthouse 1700 Seventh Street Bay City, Texas 77414 Licensing Representative Houston Lighting & Power Company Suite 610 Three Metro Center Bethesda, Maryland 20814 Rufus S. Scott, Associate General Counsel Houston Lighting & Power Company P.O. Box 61867 Houston, Texas 77208 Joseph R. Egan, Esq.

Egan & Associates, P.C.

2300 N Street, N.W.

Washington, D.C. 20037 1

J

4 Houston Ughting & Power Company bec to DCD (IE01) bec distrib, by RIV:

Regional Administrator Resident inspector DRP Director DRS-PSB Branch Chief (DRP/A)

MIS System Project Engineer (DRP/A)

RIV File Branch Chief (DRP/TSS)

R. Bachmann, OGC (MS: 15-B 18)

R. Wise, RIV l

DOCUMENT NAME: R:\\ STP\\ST0805MS.TFS To receive copy of document, iridicate in box: "C" = Copy witnout enclosures "E" = Copy Mh enclosures "N" = No copy RIV:SRl:EB C:EB D:DRP l

D:DRE(N TFStetkallmb

  • CAVanDenburgh" TPGwynn
  • ATHpwdll 111 08/07/97 08/07/97 08/07/97 08/% 97
  • Previously concurred OFFICIAL RECORD COPY 9

Houston Lighting & Power Company.

bec to DCD i bec distrib.' by RIV:

I Regional' Administrator Resident inspector.

DRP Director DRS-PSB Branch Chief (DRP/A)

MIS System Project Engineer (DRP/A)

RIV File

- Branch Chief (DRP/TSS)'

R. Bachmann, OGC (MS: 15 B 18)

R. Wise, RIV t

DOCUMENT NAME: R:\\ STP\\ST0805MS.TFS

~

- To receive copy of document. Irusicate in box: "C" = Copy wtthout enclosures "E" = Copy h enclosures "N" = No copy -

RIV: SRI:E8 C:EB D:DRP D:DRSff TFStetkallmb" CAVanDenburgh

  • TPGwynn*

ATHpwdl ill 08/07/97 08/07/97 08/07/97:

08/'%97

  • Previously_. concurred OFFICIAL RECORD COPY

ENCLOSURE 1 South Texas Project T. Cloninger, Vice President, Nuclear Engineering S. Thomas, Manager, Design Engineering S. Head, Licensing Supervisor City Public Service M. Hardt, Board Member l

NRC E, Merschoff, Regional Administrator A. Howell, Director, Division of Reactor Safety T. Stetka, Acting Chief, Engineering Branch, Division of Reactor Safety J. Tapia, Chief, Projects Branch A, Division of Reactor Projects P. Gage, Reactor inspector, Maintenance Branch, Division of Reactor Safety l

J. Clifford, Acting Director, Project Directorate IV-1, Office of Nuclear Reactor Regulation T. Alexion, Project Manager, Office of Nuclear Reactor Regulation I

(

ENCLOSURE 2 Licensee Presentation

' South Texas Project'

' Instrument Scaling and Setpoint Programs" August 5,1997 l

l t

SOUTH TEXAS PROJECT INSTRUMENT SCALING AND SETPOINT PROGRAMS August 5,1997 SOUTH TEXAS PROJECT STP: A WORLD CLASS POWER PRODUCER

SOUTH TEXAS PROJECT INSTRUMENT SETPOINT AND SCALING PROGRAMS ATTENDEES TED CLONINGER VICE PRESIDENT, NUCLEAR ENGINEERING STEVE THOMAS MANAGER, DESIGN ENGINEERING SCOTT HEAD LICENSING PageI l

L_._____._.____

l SOUTH TEXAS PROJECT INSTRUMENT SETPOINT AND SCALING PROGRAMS PURPOSE

= DESCRIBE THE MANAGEMENT DECISION-MAKING PROCESS WITH REGARD TO SCALING AND SETPOINT ISSUES

. HISTORICAL PERSPECTIVE OF SCALING AND SETPOINT PROGRAMS

. REVIEW ASSESSMENTS OF SETPOINT ISSUES

. PROVIDE SCOPE AND SCHEDULE FOR SETPOINT PROGRAM ACTION PLAN Page 2

SOUTH TEXAS PROJECT INSTRUMENT SETPOINT AND SCA. LING PROGRAMS NUCLEAR ENGINEERING DEPARTMENT PERSPECTIVE ENGINEERING SUPPORT OF PLANT OPERATION AGGRESSIVE PROBLEM RESOLUTION WITH T11E BEST EXPERTISE AVAILABLE RESOURCES, TOOLS, AND TRAINING PROVIDED TO ACHIEVE WORLD CLASS STATURE ENGINEERING SUCCESS IS MEASURED IN PLANT PERFORMANCE Page 3 l

SOUTH TEXAS PROJECT INSTRUMENT SETPOINT AND SCALING PROGRAMS SOUTH TEXAS MANAGEMENT DECISION-MAKING Prio.rity 1 -

Regulatory Requirement Required For Nuclear Safety Corrects A Significant Plant Reliability Issue Priority 2 -

Prevents Plant Trip Significant Personnel Safety Impact Corrects A Significant Regulatory Issue Significant Short Term Economic Payback Reduces Outage Duration Priority 3 -

Improves Regulatory Position 1

Reduces Possibility Of Plant Trip Enhancement With Economic Payback Improves Station Material Condition Prevents Long Term Degradation Of Equipment Page 4

SOUTH TEX.AS PROJECT INSTRUMENT SETPOINT AND SCALING PROGRAMS INSTRUMENT SCALING

. INSTRUMENT SCALING IS THE METHODOLOGY WHICH CONVERTS A PROCESS VALUE INTO AN EQUIVALENT ANALOG SIGNAL (e.g., 4 - 20 ma)

. SCALING CALCULATIONS AND DATA ARE APPLIED ROUTINELY IN THE PLANT IN THE PERFORMANCE OF SURVEILLANCES AND CALIBRATIONS i

Page 5 a,,

- l SOUTH TEXAS PROJECT INSTRUMENT SETPOINT AND SCALING PROGRAMS i

SETPOINT PROGRAM SETPOINT METHODOLOGY CALCULATES AND ENSURES THAT THE ALLOWANCE BETWEEN A PROCESS SETPOINT AND THE ANALYTICAL LIMIT IS CONSERVATIVE CONSIDERING INSTRUMENT UNCERTAINTIES Page 6 l

i Instrument Setpoint and Scaling Programs Quality Assurance Assessment 92-01 Hurst Review (52 calculations reviewed)

Hurst independent Assessment

' 7 Hurst Setpoint Program Assessment (181 cafes reviewed; 47 TS/SR cales reviewed)

Quality Assurance Assessment 95-04

- Engineering Self-Assessment

- Setpoint Self-Assessment Condition Report 1 I l I I

I I

I Engineering

)

I Evaluation Unit 1 Shutdown ISA-S67.04 Unit 2 Shutdown 1992 1993 1994 1995 1996 1997 1998

=

=

=

Scaling Calculations and Database Setpoint Calculation Revisions

=

=

Setpoint/ Scaling Methodology

(

J Page 7

,p__

y y

O SOUTH TEXAS PROJECT INSTRUMENT SETPOINT AND SCALING PROGRAMS SETPOINT AND SCALING PROGRAM UPGRADE PLAN PHASE I - ESTABLISH STANDARD SETPOINT AND SCALING METHODOLOGY AND DESIGN CRITERIA PHASE II-VALIDATE AND VERIFY SETPOINT AND SCALING CALCULATIONS PHASE III - ESTABLISH INSTRUMENT SETPOINT DATABASE SYSTEM AND COMPUTER BASED SCALING SYSTEM Page 8

SOUTH TEXAS PROJECT INSTRUMENT SETPOINT AND SCALING PROGRAMS INSTRUMENT SCALING PROGRAM

. PRIOR TO 1994, INSTRUMENT SCALING PROGRAM CONTROLLED BY MAINTENANCE DEPARTMENT

. I & C TECHNICIANS USE SCALING DATA ROUTINELY FOR INSTRUMENT CALCULATIONS AND SURVEILLANCES

. SOME PLANT CHANGES WERE NOT CORRECTLY INCORPORATED INTO THE SCALING CALCULATIONS

. CONTROL OF INSTRUMENT SCALING PROGRAM TRANSFERRED TO ENGINEERING Page 9

SOUTH TEXAS PROJECT INSTRUMENT SETPOINT AND SCALING PROGRAMS INSTRUMENT SCALING PROGRAM (CONT'D)

. OVER 16,000 SCALING CALCULATIONS WERE VERIFIED AND ENTERED INTO A COMPUTER DATABASE OVER A THREE-YEAR PERIOD (1994,1995,1996)

DESIGN BASIS DATA CAN BE DIRECTLY DOWNLOADED INTO WORK DOCUMENTS BY I & C TECHNICIANS Page 10

iiiiii-..

SOUTH TEXAS PROJECT INSTRUMENT SETPOINT AND SCALING PROGRAMS SETPOINT AND SCALING PROGRAM ASSESSMENTS MULTIPLE INTERNAL AND EXTERNAL ASSESSMENTS "DID NOT DETECT ANY SAFETY LIMIT THAT HAD BEEN EXCEEDED" - QUALITY ASSURANCE ASSESSMENT 92-01 (1/92 -

4/92)

" CONCLUSIONS OF THIS REPORT, HOWEVER, DO NOT IDENTIFY AN IMMEDIATE PROBLEM" - HURST REVIEW (12/93)

"THE CALCULATIONS THAT UTILIZE THE WCAP APPEAR TO BE TECHNICALLY ADEQUATE... THE CALCULATIONS THAT UTILIZE THE BECHTEL METHODOLOGY APPEAR TO BE TECHNICALLY ADEQUATE IN MOST AREAS." - HURST ASSESSMENT (1/94)

Page 11 l

SOUTH TEXAS PROJECT INSTRUMENT SETPOINT AND SCALING PROGRAMS SETPOINT AND SCALING PROGRAM ASSESSMENTS (CONT'D)

"[SOME CALCULATIONS REQUIRE MAJOR REVISION] TO BRING THEM UP TO CURRENT STANDARDS FOR DOCUMENTING A SETPOINT'S BASIS" - HURST REPORT (6/95)

" ERRORS RESULTED IN ADDITIONAL SETPOINT CONSERVATISM" - SETPOINT SELF-ASSESSMENT (2/97)

" REVIEW FAILED TO IDENTIFY ANY PENDING OPERABILITY CONCERNS" - CONDITION REPORT ENGINEERING EVALUATION (3/97)

Page 12

4 SOUTH TEXAS PROJECT INSTRUMENT SETPOINT AND SCALING PROGRAMS j

i i

SETPOINT AND SCALING PROGRAM ASSESSMENTS (CONT'D~)

f CONCLUSIONS DRAWN FROM ASSESSMENTS SETPOINT CALCULATIONS NEED ENHANCEMENT TO MEET i

CURRENT DOCUMENTATION STANDARDS THE LIKELIHOOD OF AN OPERABILITY OR SAFETY ISSUE WITH SETPOINT CALCULATIONS IS SMALL Page 13 l

4 i

J

. l SOUTH TEXAS PROJECT INSTRUMENT SETPOINT AND SCALING PROGRAMS SETPOINT PROGRAM ACTION PLAN

. CLASSIFY SETPOINTS ACCORDING TO QUALITY LEVEL VALIDATE THE BASES FOR EXISTING SETPOINTS RE-PERFORM CALCULATIONS TO DOCUMENT SETPOINT BASES IN ACCORDANCE WITH INDUSTRY STANDARDS ACTION PLAN IS CURRENTLY UNDERWAY - SCHEDULED FOR COMPLETION IN 1998 Page 14

l l

j i

SOUTH TEXAS PROJECT INSTRUMENT SETPOINT AND SCALING PROGRAMS SETPOINT IMPROVEMENT PROGRAM SCOPE AND SCHEDULE (PRELIMINARY)

NAME SCHEDULED START SCHEDULED FINISH Classify Setpoints 8/4/97 9/5/97 Quality Level 1 Review Setpoint Bases 1/12/98 3/6/98 Revise / Perform New Calculations 3/9/98 6/26/98 Quality Level 2 Evaluate Setpoint Bases 8/25/97 1/9/98 Revise / Perform New Calculations 1/12/98 8/21/98 Quality Level 3 Evaluate Serpoint Bases 8/25/97 1/9/98 Revise / Perform New Calculations 1/12/98 8/21/98 Quality Level 4 & 5 Evaluate Setpoint Bases 2/2/98 4/24/98 Revise / Create new basis documents 9/1/98 12/21/98 T/S LCO Values (QL 2&3)

Evalaate Bases 8/4/97 10/24/97 Revise / Perform New Calculations 10/27/97 3/13/98 Process Improvements Design Change Procedure Revisions 9/2/97 11/24/97 Calculation Procedure Revisions 1/5/98 4/24/98 Setpoint Training 8/4/97 2/27/98 Page 15 L_.___._._____